The Experts below are selected from a list of 111 Experts worldwide ranked by ideXlab platform
F R Tay - One of the best experts on this subject based on the ideXlab platform.
-
Tubular occlusion optimizes bonding of hydrophobic resins to dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. Ferrari, F R TayAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol- dehydrated dentin. Mid-coronal and deep acid- etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre- treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and PADC-pre-treated deep dentin. The use of tubular occluding agents optimized bonding of hydrophobic resins to dentin
F. T. Sadek - One of the best experts on this subject based on the ideXlab platform.
-
Tubular Occlusion Optimizes Bonding of Hydrophobic Resins to Dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. FerrariAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol-dehydrated dentin. Mid-coronal and deep acid-etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre-treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and ...
-
Tubular occlusion optimizes bonding of hydrophobic resins to dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. Ferrari, F R TayAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol- dehydrated dentin. Mid-coronal and deep acid- etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre- treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and PADC-pre-treated deep dentin. The use of tubular occluding agents optimized bonding of hydrophobic resins to dentin
M. Ferrari - One of the best experts on this subject based on the ideXlab platform.
-
Tubular Occlusion Optimizes Bonding of Hydrophobic Resins to Dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. FerrariAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol-dehydrated dentin. Mid-coronal and deep acid-etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre-treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and ...
-
Tubular occlusion optimizes bonding of hydrophobic resins to dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. Ferrari, F R TayAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol- dehydrated dentin. Mid-coronal and deep acid- etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre- treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and PADC-pre-treated deep dentin. The use of tubular occluding agents optimized bonding of hydrophobic resins to dentin
Westsik, Joseph H. - One of the best experts on this subject based on the ideXlab platform.
-
Radionuclide Retention Mechanisms in Secondary Waste-Form Testing: Phase II
Pacific Northwest National Laboratory (U.S.), 2011Co-Authors: Um Wooyong, Cantrell, Kirk J., Chung Chul-woo, Parker, Kent E., Serne R. Jeffrey, Valenta, Michelle M., Yang Jungseok, Engelhard, Mark H., Wang Guohui, Westsik, Joseph H.Abstract:This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate candidate stabilization technologies that have the potential to successfully treat liquid secondary waste stream effluents produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). WRPS is considering the design and construction of a Solidification Treatment Unit (STU) for the Effluent Treatment Facility (ETF) at Hanford. The ETF, a multi-waste, treatment-and-storage unit that has been permitted under the Resource Conservation and Recovery Act (RCRA), can accept dangerous, low-level, and mixed wastewaters for treatment. The STU needs to be operational by 2018 to receive secondary liquid waste generated during operation of the WTP. The STU will provide the additional capacity needed for ETF to process the increased volume of secondary waste expected to be produced by WTP. This report on radionuclide retention mechanisms describes the testing and characterization results that improve understanding of radionuclide retention mechanisms, especially for pertechnetate, {sup 99}TcO{sub 4}{sup -} in four different waste forms: Cast Stone, DuraLith alkali aluminosilicate geopolymer, encapsulated fluidized bed steam reforming (FBSR) product, and Ceramicrete phosphate bonded ceramic. These data and results will be used to fill existing data gaps on the candidate technologies to support a decision-making process that will identify a subset of the candidate waste forms that are most promising and should undergo further performance testing
-
Engineering-Scale Demonstration of DuraLith and Ceramicrete Waste Forms
Pacific Northwest National Laboratory (U.S.), 2011Co-Authors: Josephson, Gary B., Westsik, Joseph H., Pires, Richard P., Bickford Jody, Foote, Martin W.Abstract:To support the selection of a waste form for the liquid secondary wastes from the Hanford Waste Immobilization and Treatment Plant, Washington River Protection Solutions (WRPS) has initiated secondary waste form testing on four candidate waste forms. Two of the candidate waste forms have not been developed to scale as the more mature waste forms. This work describes engineering-scale demonstrations conducted on Ceramicrete and DuraLith candidate waste forms. Both candidate waste forms were successfully demonstrated at an engineering scale. A preliminary conceptual design could be prepared for full-scale production of the candidate waste forms. However, both waste forms are still too immature to support a detailed design. Formulations for each candidate waste form need to be developed so that the material has a longer working time after mixing the liquid and solid constituents together. Formulations optimized based on previous lab studies did not have sufficient working time to support large-scale testing. The engineering-scale testing was successfully completed using modified formulations. Further lab development and parametric studies are needed to optimize formulations with adequate working time and assess the effects of changes in raw materials and process parameters on the final product performance. Studies on effects of mixing intensity on the initial set time of the waste forms are also needed
-
Secondary Waste Form Down Selection Data Package – Ceramicrete
Pacific Northwest National Laboratory (U.S.), 2011Co-Authors: Cantrell, Kirk J., Westsik, Joseph H.Abstract:As part of high-level waste pretreatment and immobilized low activity waste processing, liquid secondary wastes will be generated that will be transferred to the Effluent Treatment Facility on the Hanford Site for further treatment. These liquid secondary wastes will be converted to stable solid waste forms that will be disposed in the Integrated Disposal Facility. Currently, four waste forms are being considered for stabilization and solidification of the liquid secondary wastes. These waste forms are Cast Stone, Ceramicrete, DuraLith, and Fluidized Bed Steam Reformer. The preferred alternative will be down selected from these four waste forms. Pacific Northwest National Laboratory is developing data packages to support the down selection process. The objective of the data packages is to identify, evaluate, and summarize the existing information on the four waste forms being considered for stabilization and solidification of the liquid secondary wastes. The information included will be based on information available in the open literature and from data obtained from testing currently underway. This data package is for the Ceramicrete waste form. Ceramicrete is a relatively new engineering material developed at Argonne National Laboratory to treat radioactive and hazardous waste streams (e.g., Wagh 2004; Wagh et al. 1999a, 2003; Singh et al. 2000). This cement-like waste form can be used to treat solids, liquids, and sludges by chemical immobilization, microencapsulation, and/or macroencapsulation. The Ceramicrete technology is based on chemical reaction between phosphate anions and metal cations to form a strong, dense, durable, low porosity matrix that immobilizes hazardous and radioactive contaminants as insoluble phosphates and microencapsulates insoluble radioactive components and other constituents that do not form phosphates. Ceramicrete is a type of phosphate-bonded ceramic, which are also known as chemically bonded phosphate ceramics. The Ceramicrete binder is formed through an acid-base reaction between calcined magnesium oxide (MgO; a base) and potassium hydrogen phosphate (KH{sub 2}PO{sub 4}; an acid) in aqueous solution. The reaction product sets at room temperature to form a highly crystalline material. During the reaction, the hazardous and radioactive contaminants also react with KH{sub 2}PO{sub 4} to form highly insoluble phosphates. In this data package, physical property and waste acceptance data for Ceramicrete waste forms fabricated with wastes having compositions that were similar to those expected for secondary waste effluents, as well as secondary waste effluent simulants from the Hanford Tank Waste Treatment and Immobilization Plant were reviewed. With the exception of one secondary waste form formulation (25FA+25 W+1B.A. fabricated with the mixed simulant did not meet the compressive strength requirement), all the Ceramicrete waste forms that were reviewed met or exceeded Integrated Disposal Facility waste acceptance criteria
-
Waste Acceptance Testing of Secondary Waste Forms: Cast Stone, Ceramicrete and DuraLith
Pacific Northwest National Laboratory (U.S.), 2011Co-Authors: Mattigod Shas, Westsik, Joseph H., Chung Chul-woo, Lindberg, Michael J., Parker, Kent E.Abstract:To support the selection of a waste form for the liquid secondary wastes from WTP, Washington River Protection Solutions has initiated secondary-waste-form testing work at Pacific Northwest National Laboratory (PNNL). In anticipation of a down-selection process for a waste form for the Solidification Treatment Unit to be added to the ETF, PNNL is conducting tests on four candidate waste forms to evaluate their ability to meet potential waste acceptance criteria for immobilized secondary wastes that would be placed in the IDF. All three waste forms demonstrated compressive strengths above the minimum 3.45 MPa (500 psi) set as a target for cement-based waste forms. Further, none of the waste forms showed any significant degradation in compressive strength after undergoing thermal cycling (30 cycles in a 10 day period) between -40 C and 60 C or water immersion for 90 days. The three leach test methods are intended to measure the diffusion rates of contaminants from the waste forms. Results are reported in terms of diffusion coefficients and a leachability index (LI) calculated based on the diffusion coefficients. A smaller diffusion coefficient and a larger LI are desired. The NRC, in its Waste Form Technical Position (NRC 1991), provides recommendations and guidance regarding methods to demonstrate waste stability for land disposal of radioactive waste. Included is a recommendation to conduct leach tests using the ANS 16.1 method. The resulting leachability index (LI) should be greater than 6.0. For Hanford secondary wastes, the LI > 6.0 criterion applies to sodium leached from the waste form. For technetium and iodine, higher targets of LI > 9 for Tc and LI > 11 for iodine have been set based on early waste-disposal risk and performance assessment analyses. The results of these three leach tests conducted for a total time between 11days (ASTM C1308) to 90 days (ANS 16.1) showed: (1) Technetium diffusivity: ANSI/ANS 16.1, ASTM C1308, and EPA 1315 tests indicated that all the waste forms had leachability indices better than the target LI > 9 for technetium; (2) Rhenium diffusivity: Cast Stone 2M specimens, when tested using EPA 1315 protocol, had leachability indices better than the target LI > 9 for technetium based on rhenium as a surrogate for technetium. All other waste forms tested by ANSI/ANS 16.1, ASTM C1308, and EPA 1315 test methods had leachability indices that were below the target LI > 9 for Tc based on rhenium release. These studies indicated that use of Re(VII) as a surrogate for 99Tc(VII) in low temperature secondary waste forms containing reductants will provide overestimated diffusivity values for 99Tc. Therefore, it is not appropriate to use Re as a surrogate 99Tc in future low temperature waste form studies. (3) Iodine diffusivity: ANSI/ANS 16.1, ASTM C1308, and EPA 1315 tests indicated that the three waste forms had leachability indices that were below the target LI > 11 for iodine. Therefore, it may be necessary to use a more effective sequestering material than silver zeolite used in two of the waste forms (Ceramicrete and DuraLith); (4) Sodium diffusivity: All the waste form specimens tested by the three leach methods (ANSI/ANS 16.1, ASTM C1308, and EPA 1315) exceeded the target LI value of 6; (5) All three leach methods (ANS 16.1, ASTM C1308 and EPA 1315) provided similar 99Tc diffusivity values for both short-time transient diffusivity effects as well as long-term ({approx}90 days) steady diffusivity from each of the three tested waste forms (Cast Stone 2M, Ceramicrete and DuraLith). Therefore, any one of the three methods can be used to determine the contaminant diffusivities from a selected waste form
-
Secondary Waste Form Screening Test Results—THOR® Fluidized Bed Steam Reforming Product in a Geopolymer Matrix
Pacific Northwest National Laboratory (U.S.), 2011Co-Authors: Pires, Richard P., Westsik, Joseph H., Mattigod Shas, Serne R. Jeffrey, Golovich, Elizabeth C., Valenta, Michelle M., Parker, Kent E.Abstract:Screening tests are being conducted to evaluate waste forms for immobilizing secondary liquid wastes from the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Plans are underway to add a stabilization treatment unit to the Effluent Treatment Facility to provide the needed capacity for treating these wastes from WTP. The current baseline is to use a Cast Stone cementitious waste form to solidify the wastes. Through a literature survey, DuraLith alkali-aluminosilicate geopolymer, fluidized-bed steam reformation (FBSR) granular product encapsulated in a geopolymer matrix, and a Ceramicrete phosphate-bonded ceramic were identified both as candidate waste forms and alternatives to the baseline. These waste forms have been shown to meet waste disposal acceptance criteria, including compressive strength and universal treatment standards for Resource Conservation and Recovery Act (RCRA) metals (as measured by the toxicity characteristic leaching procedure [TCLP]). Thus, these non-cementitious waste forms should also be acceptable for land disposal. Information is needed on all four waste forms with respect to their capability to minimize the release of technetium. Technetium is a radionuclide predicted to be in the secondary liquid wastes in small quantities, but the Integrated Disposal Facility (IDF) risk assessment analyses show that technetium, even at low mass, produces the largest contribution to the estimated IDF disposal impacts to groundwater
David Henry Pashley - One of the best experts on this subject based on the ideXlab platform.
-
Tubular Occlusion Optimizes Bonding of Hydrophobic Resins to Dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. FerrariAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol-dehydrated dentin. Mid-coronal and deep acid-etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre-treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and ...
-
Tubular occlusion optimizes bonding of hydrophobic resins to dentin
Journal of Dental Research, 2007Co-Authors: F. T. Sadek, David Henry Pashley, M. Ferrari, F R TayAbstract:Although hydrophobic resins may be bonded to acid-etched dentin with an ethanol wet-bonding technique, the protocol is sensitive to moisture contamination when bonding is performed in deep dentin. This study tested the hypothesis that the use of oxalate or poly(glutamic) acid-modified, diluted Ceramicrete (PADC) for dentinal tubule occlusion prevents fluid contamination and improves the bonding of an experimental hydrophobic adhesive to acid-etched, ethanol- dehydrated dentin. Mid-coronal and deep acid- etched moist dentin pre-treated with oxalate or PADC was dehydrated by ethanol wet-bonding and infiltrated with the experimental three-step etch-and-rinse hydrophobic adhesive under simulated pulpal pressure. Tensile bond strengths to deep dentin without pre-treatment were severely compromised. Conversely, oxalate and PADC pre- treatments reduced dentin permeability, prevented water contamination, and improved bond strengths. Minimal nanoleakage was identified within hybrid layers created in the oxalate- and PADC-pre-treated deep dentin. The use of tubular occluding agents optimized bonding of hydrophobic resins to dentin