The Experts below are selected from a list of 606 Experts worldwide ranked by ideXlab platform
F Matonti - One of the best experts on this subject based on the ideXlab platform.
-
lamellar Corneal lenticule graft to treat keratolysis after alphacor keratoprosthesis implantation
European Journal of Ophthalmology, 2015Co-Authors: Louis Hoffart, Gerard Carles, F MatontiAbstract:PURPOSE Clinical assessment of AlphaCor keratoprosthesis and evaluation of surgical method to treat keratolysis in case of stromal Necrosis occurrence. METHODS This is a noncomparative, retrospective, interventional case series. The medical records of 12 eyes of 12 patients who underwent consecutive AlphaCor keratoprosthesis implantations were reviewed. Patients with severe bilateral Corneal pathology unsuitable for a conventional Corneal graft, a best-corrected visual acuity (BCVA) from light perception (LP) to 20/200, with no active ocular surface inflammation, controlled intraocular pressure prior to the surgery, and an unstimulated Schirmer test of >2.5 mm at 5 minutes were included. Postoperative medications included topical dexamethasone, ciprofloxacin, and 2% cyclosporine A. Main outcome measures included BCVA and complications occurrence. RESULTS After a mean follow-up of 25 ± 12.3 months (range 2-38 months), 8 (66.7%) AlphaCor devices were retained. Postoperative BCVA ranged from LP to 20/63 (mean gain of 2.5 ± 3.1 lines). Seven cases of stromal melt (58.3%) occurred. Three were reversed to penetrating keratoplasty and 3 had a donor Corneal layer fixated over the AlphaCor with satisfactory results (mean follow-up 23 ± 1.6 months). There were no instances of endophthalmitis, retinal detachment, or glaucoma exacerbation. CONCLUSIONS AlphaCor showed a low incidence of the classic keratoprosthesis complications but a high occurrence of recipient Cornea Necrosis. Corneal melts were successfully managed in 3 cases by lamellar Corneal lenticule graft, thereby increasing the retention of AlphaCor and maintaining BCVA.
Louis Hoffart - One of the best experts on this subject based on the ideXlab platform.
-
lamellar Corneal lenticule graft to treat keratolysis after alphacor keratoprosthesis implantation
European Journal of Ophthalmology, 2015Co-Authors: Louis Hoffart, Gerard Carles, F MatontiAbstract:PURPOSE Clinical assessment of AlphaCor keratoprosthesis and evaluation of surgical method to treat keratolysis in case of stromal Necrosis occurrence. METHODS This is a noncomparative, retrospective, interventional case series. The medical records of 12 eyes of 12 patients who underwent consecutive AlphaCor keratoprosthesis implantations were reviewed. Patients with severe bilateral Corneal pathology unsuitable for a conventional Corneal graft, a best-corrected visual acuity (BCVA) from light perception (LP) to 20/200, with no active ocular surface inflammation, controlled intraocular pressure prior to the surgery, and an unstimulated Schirmer test of >2.5 mm at 5 minutes were included. Postoperative medications included topical dexamethasone, ciprofloxacin, and 2% cyclosporine A. Main outcome measures included BCVA and complications occurrence. RESULTS After a mean follow-up of 25 ± 12.3 months (range 2-38 months), 8 (66.7%) AlphaCor devices were retained. Postoperative BCVA ranged from LP to 20/63 (mean gain of 2.5 ± 3.1 lines). Seven cases of stromal melt (58.3%) occurred. Three were reversed to penetrating keratoplasty and 3 had a donor Corneal layer fixated over the AlphaCor with satisfactory results (mean follow-up 23 ± 1.6 months). There were no instances of endophthalmitis, retinal detachment, or glaucoma exacerbation. CONCLUSIONS AlphaCor showed a low incidence of the classic keratoprosthesis complications but a high occurrence of recipient Cornea Necrosis. Corneal melts were successfully managed in 3 cases by lamellar Corneal lenticule graft, thereby increasing the retention of AlphaCor and maintaining BCVA.
Gerard Carles - One of the best experts on this subject based on the ideXlab platform.
-
lamellar Corneal lenticule graft to treat keratolysis after alphacor keratoprosthesis implantation
European Journal of Ophthalmology, 2015Co-Authors: Louis Hoffart, Gerard Carles, F MatontiAbstract:PURPOSE Clinical assessment of AlphaCor keratoprosthesis and evaluation of surgical method to treat keratolysis in case of stromal Necrosis occurrence. METHODS This is a noncomparative, retrospective, interventional case series. The medical records of 12 eyes of 12 patients who underwent consecutive AlphaCor keratoprosthesis implantations were reviewed. Patients with severe bilateral Corneal pathology unsuitable for a conventional Corneal graft, a best-corrected visual acuity (BCVA) from light perception (LP) to 20/200, with no active ocular surface inflammation, controlled intraocular pressure prior to the surgery, and an unstimulated Schirmer test of >2.5 mm at 5 minutes were included. Postoperative medications included topical dexamethasone, ciprofloxacin, and 2% cyclosporine A. Main outcome measures included BCVA and complications occurrence. RESULTS After a mean follow-up of 25 ± 12.3 months (range 2-38 months), 8 (66.7%) AlphaCor devices were retained. Postoperative BCVA ranged from LP to 20/63 (mean gain of 2.5 ± 3.1 lines). Seven cases of stromal melt (58.3%) occurred. Three were reversed to penetrating keratoplasty and 3 had a donor Corneal layer fixated over the AlphaCor with satisfactory results (mean follow-up 23 ± 1.6 months). There were no instances of endophthalmitis, retinal detachment, or glaucoma exacerbation. CONCLUSIONS AlphaCor showed a low incidence of the classic keratoprosthesis complications but a high occurrence of recipient Cornea Necrosis. Corneal melts were successfully managed in 3 cases by lamellar Corneal lenticule graft, thereby increasing the retention of AlphaCor and maintaining BCVA.