The Experts below are selected from a list of 81 Experts worldwide ranked by ideXlab platform

Qiqin Wang - One of the best experts on this subject based on the ideXlab platform.

  • determination of l norvaline and l tryptophan in dietary supplements by nano lc using an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column
    Journal of Pharmaceutical Analysis, 2020
    Co-Authors: Elena Sanchezlopez, Qiqin Wang, Zhengjin Jiang, Maria Luisa Marina
    Abstract:

    Abstract An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl (FMOC) derivatized amino acids by nano-liquid chromatography. The mobile phase was optimized including the apparent pH, content of ACN, and concentration of the buffer to obtain a satisfactory enantioresolution performance. 27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested, and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them. Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity, precision, accuracy, limits of detection (LOD) and quantitation (LOQ) showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements. LOD and LOQ values were 9.3 and 31 μM for norvaline enantiomers and 7.5 and 25 μM for tryptophan enantiomers, respectively. The contents of d -norvaline and d -tryptophan were below their respective LODs in all the analyzed samples. Quantitation of l -tryptophan and l -norvaline showed good agreement with the labeled contents except for one sample which did not show presence of l -norvaline, contrary to the label indication.

  • preparation of an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column for the enantioseparation of amino acids by nano liquid chromatography
    Journal of Chromatography A, 2019
    Co-Authors: Qiqin Wang, Zhengjin Jiang, Elena Sanchezlopez, Maria Luisa Marina
    Abstract:

    An O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was prepared by a facile "one-step" strategy within a 100 μm I.D. capillary. The influence of the methanol, ethylene glycol and water volume ratio, reaction temperature and time, cetyltrimethylammonium bromide and MQD monomers content and volume ratio of tetramethoxysilane and vinyltrimethoxysilane was investigated to obtain a satisfactory morphology of monolithic columns. The optimized MQD-silica hybrid monolithic column was evaluated in terms of permeability, stability, efficiency, reproducibility, and was characterized by scanning electron microscopy and nano-liquid chromatography. Among the 52 N-derivatized protein and non-protein amino acids, a total of 44 analytes could be baseline enantioseparated using the optimized conditions in either reversed phase mode (RPM) or polar organic phase mode (POM). The results showed that POM (ACN/MeOH/HAc/TEA (60/40/0.055/0.005, v/v/v/v)) offered better performance than RPM (10 mM ammonium acetate/ACN (30/70, v/v) (apparent pH=5.3)) in terms of enantioresolution and efficiency with shorter analysis times.

  • enantioseparation of n derivatized amino acids by micro liquid chromatography using carbamoylated quinidine functionalized monolithic stationary phase
    Journal of Chromatography A, 2014
    Co-Authors: Qiqin Wang, Jun Feng, Hai Han, Peijie Zhu, Maria Luisa Marina, Jacques Crommen, Zhengjin Jiang
    Abstract:

    In order to obtain satisfactory column permeability, efficiency and selectivity for micro-HPLC, a capillary monolithic column containing O-9-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD) as chiral selector was re-optimized. The monolithic column was used to successfully enantioresolve a wide range of N-derivatized amino acids including alanine, leucine, methionine, threonine, phenylalanine, valine, serine, isoleucine, tryptophan, and cysteine. The influence of mobile phase parameters, such as the organic solvent type and concentration, the apparent pH, and buffer concentration, on retention and enantioseparation of N-derivatized amino acids has been investigated. 3,5-dinitrobenzoyl-amino acids and 3,5-dichlorobenzoyl-amino acids were resolved into enantiomers with exceptionally high selectivity and resolution. The chemoselectivity of the monolithic column for a multicomponent mixture of N-derivatized amino acids was also investigated. A mixture of three pairs of 3,5-dichlorobenzoyl-amino acids could be fully resolved in 22.5 min.

Maria Luisa Marina - One of the best experts on this subject based on the ideXlab platform.

  • determination of l norvaline and l tryptophan in dietary supplements by nano lc using an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column
    Journal of Pharmaceutical Analysis, 2020
    Co-Authors: Elena Sanchezlopez, Qiqin Wang, Zhengjin Jiang, Maria Luisa Marina
    Abstract:

    Abstract An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl (FMOC) derivatized amino acids by nano-liquid chromatography. The mobile phase was optimized including the apparent pH, content of ACN, and concentration of the buffer to obtain a satisfactory enantioresolution performance. 27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested, and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them. Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity, precision, accuracy, limits of detection (LOD) and quantitation (LOQ) showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements. LOD and LOQ values were 9.3 and 31 μM for norvaline enantiomers and 7.5 and 25 μM for tryptophan enantiomers, respectively. The contents of d -norvaline and d -tryptophan were below their respective LODs in all the analyzed samples. Quantitation of l -tryptophan and l -norvaline showed good agreement with the labeled contents except for one sample which did not show presence of l -norvaline, contrary to the label indication.

  • preparation of an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column for the enantioseparation of amino acids by nano liquid chromatography
    Journal of Chromatography A, 2019
    Co-Authors: Qiqin Wang, Zhengjin Jiang, Elena Sanchezlopez, Maria Luisa Marina
    Abstract:

    An O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was prepared by a facile "one-step" strategy within a 100 μm I.D. capillary. The influence of the methanol, ethylene glycol and water volume ratio, reaction temperature and time, cetyltrimethylammonium bromide and MQD monomers content and volume ratio of tetramethoxysilane and vinyltrimethoxysilane was investigated to obtain a satisfactory morphology of monolithic columns. The optimized MQD-silica hybrid monolithic column was evaluated in terms of permeability, stability, efficiency, reproducibility, and was characterized by scanning electron microscopy and nano-liquid chromatography. Among the 52 N-derivatized protein and non-protein amino acids, a total of 44 analytes could be baseline enantioseparated using the optimized conditions in either reversed phase mode (RPM) or polar organic phase mode (POM). The results showed that POM (ACN/MeOH/HAc/TEA (60/40/0.055/0.005, v/v/v/v)) offered better performance than RPM (10 mM ammonium acetate/ACN (30/70, v/v) (apparent pH=5.3)) in terms of enantioresolution and efficiency with shorter analysis times.

  • enantioseparation of n derivatized amino acids by micro liquid chromatography using carbamoylated quinidine functionalized monolithic stationary phase
    Journal of Chromatography A, 2014
    Co-Authors: Qiqin Wang, Jun Feng, Hai Han, Peijie Zhu, Maria Luisa Marina, Jacques Crommen, Zhengjin Jiang
    Abstract:

    In order to obtain satisfactory column permeability, efficiency and selectivity for micro-HPLC, a capillary monolithic column containing O-9-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD) as chiral selector was re-optimized. The monolithic column was used to successfully enantioresolve a wide range of N-derivatized amino acids including alanine, leucine, methionine, threonine, phenylalanine, valine, serine, isoleucine, tryptophan, and cysteine. The influence of mobile phase parameters, such as the organic solvent type and concentration, the apparent pH, and buffer concentration, on retention and enantioseparation of N-derivatized amino acids has been investigated. 3,5-dinitrobenzoyl-amino acids and 3,5-dichlorobenzoyl-amino acids were resolved into enantiomers with exceptionally high selectivity and resolution. The chemoselectivity of the monolithic column for a multicomponent mixture of N-derivatized amino acids was also investigated. A mixture of three pairs of 3,5-dichlorobenzoyl-amino acids could be fully resolved in 22.5 min.

Zhengjin Jiang - One of the best experts on this subject based on the ideXlab platform.

  • determination of l norvaline and l tryptophan in dietary supplements by nano lc using an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column
    Journal of Pharmaceutical Analysis, 2020
    Co-Authors: Elena Sanchezlopez, Qiqin Wang, Zhengjin Jiang, Maria Luisa Marina
    Abstract:

    Abstract An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl (FMOC) derivatized amino acids by nano-liquid chromatography. The mobile phase was optimized including the apparent pH, content of ACN, and concentration of the buffer to obtain a satisfactory enantioresolution performance. 27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested, and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them. Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity, precision, accuracy, limits of detection (LOD) and quantitation (LOQ) showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements. LOD and LOQ values were 9.3 and 31 μM for norvaline enantiomers and 7.5 and 25 μM for tryptophan enantiomers, respectively. The contents of d -norvaline and d -tryptophan were below their respective LODs in all the analyzed samples. Quantitation of l -tryptophan and l -norvaline showed good agreement with the labeled contents except for one sample which did not show presence of l -norvaline, contrary to the label indication.

  • preparation of an o 2 methacryloyloxy ethylcarbamoyl 10 11 Dihydroquinidine silica hybrid monolithic column for the enantioseparation of amino acids by nano liquid chromatography
    Journal of Chromatography A, 2019
    Co-Authors: Qiqin Wang, Zhengjin Jiang, Elena Sanchezlopez, Maria Luisa Marina
    Abstract:

    An O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD)-silica hybrid monolithic column was prepared by a facile "one-step" strategy within a 100 μm I.D. capillary. The influence of the methanol, ethylene glycol and water volume ratio, reaction temperature and time, cetyltrimethylammonium bromide and MQD monomers content and volume ratio of tetramethoxysilane and vinyltrimethoxysilane was investigated to obtain a satisfactory morphology of monolithic columns. The optimized MQD-silica hybrid monolithic column was evaluated in terms of permeability, stability, efficiency, reproducibility, and was characterized by scanning electron microscopy and nano-liquid chromatography. Among the 52 N-derivatized protein and non-protein amino acids, a total of 44 analytes could be baseline enantioseparated using the optimized conditions in either reversed phase mode (RPM) or polar organic phase mode (POM). The results showed that POM (ACN/MeOH/HAc/TEA (60/40/0.055/0.005, v/v/v/v)) offered better performance than RPM (10 mM ammonium acetate/ACN (30/70, v/v) (apparent pH=5.3)) in terms of enantioresolution and efficiency with shorter analysis times.

  • enantioseparation of n derivatized amino acids by micro liquid chromatography using carbamoylated quinidine functionalized monolithic stationary phase
    Journal of Chromatography A, 2014
    Co-Authors: Qiqin Wang, Jun Feng, Hai Han, Peijie Zhu, Maria Luisa Marina, Jacques Crommen, Zhengjin Jiang
    Abstract:

    In order to obtain satisfactory column permeability, efficiency and selectivity for micro-HPLC, a capillary monolithic column containing O-9-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-Dihydroquinidine (MQD) as chiral selector was re-optimized. The monolithic column was used to successfully enantioresolve a wide range of N-derivatized amino acids including alanine, leucine, methionine, threonine, phenylalanine, valine, serine, isoleucine, tryptophan, and cysteine. The influence of mobile phase parameters, such as the organic solvent type and concentration, the apparent pH, and buffer concentration, on retention and enantioseparation of N-derivatized amino acids has been investigated. 3,5-dinitrobenzoyl-amino acids and 3,5-dichlorobenzoyl-amino acids were resolved into enantiomers with exceptionally high selectivity and resolution. The chemoselectivity of the monolithic column for a multicomponent mixture of N-derivatized amino acids was also investigated. A mixture of three pairs of 3,5-dichlorobenzoyl-amino acids could be fully resolved in 22.5 min.

Wolfgang Lindner - One of the best experts on this subject based on the ideXlab platform.

Vahideh Zadsirjan - One of the best experts on this subject based on the ideXlab platform.