Luc Simard - One of the best experts on this subject based on the ideXlab platform.

  • the infrared imaging spectrograph iris for tmt volume phase holographic grating performance testing and discussion
    arXiv: Instrumentation and Methods for Astrophysics, 2014
    Co-Authors: Shaojie Chen, Elliot Meyer, James E Larkin, Etsuko Mieda, Shelley A. Wright, Anna M Moore, Jerome Maire, Luc Simard
    Abstract:

    Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential Dispersing Element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82{\mu}m (H-band) to produce a spectral resolution of 4000 and 1.19- 1.37 {\mu}m (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629{\mu}m and 1.27{\mu}m, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5 degree deviation from the Bragg angle, and 25%-28% decrease at J-band when 5{\deg} deviation from the Bragg angle.

  • The infrared imaging spectrograph (IRIS) for TMT: volume phase holographic grating performance testing and discussion
    Ground-based and Airborne Instrumentation for Astronomy V. Proc. SPIE, 2014
    Co-Authors: Shaojie Chen, Elliot Meyer, James E Larkin, Etsuko Mieda, Judith Maire, Shelley A. Wright, Anna M Moore, Luc Simard
    Abstract:

    Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential Dispersing Element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82μm (H-band) to produce a spectral resolution of 4000 and 1.19-1.37μm (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629μm and 1.27μm, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5° deviation from the Bragg angle, and 25%-28% decrease at J-band when 5° deviation from the Bragg angle.

Lee Hanshin - One of the best experts on this subject based on the ideXlab platform.

  • Mass production of volume phase holographic gratings for the VIRUS spectrograph array
    'SPIE-Intl Soc Optical Eng', 2014
    Co-Authors: Chonis, Taylor S., Hill, Gary J., Clemens J. Christopher, Lee Hanshin, Frantz Amy, Tuttle, Sarah E., Adams, Joshua J., Marshall J. L., Depoy D. L., Prochaska Travis
    Abstract:

    The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its Dispersing Element. The instrument utilizes the grating in first-order for 350-550 nm. Including witness samples, a suite of 170 VPH gratings has been mass produced for VIRUS. Here, we present the design of the VIRUS VPH gratings and a discussion of their mass production. We additionally present the design and functionality of a custom apparatus that has been used to rapidly test the first-order diffraction efficiency of the gratings for various discrete wavelengths within the VIRUS spectral range. This device has been used to perform both in-situ tests to monitor the effects of adjustments to the production prescription as well as to carry out the final acceptance tests of the gratings' diffraction efficiency. Finally, we present the as-built performance results for the entire suite of VPH gratings.Comment: 16 pages, 11 figures, 2 tables. To be published in Proc. SPIE, 2014, "Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation", 9151-53. The work presented in this article follows from arXiv:1207:448

  • Methods for evaluating the performance of volume phase holographic gratings for the VIRUS spectrograph array
    'SPIE-Intl Soc Optical Eng', 2012
    Co-Authors: Chonis, Taylor S., Hill, Gary J., Clemens J. Christopher, Dunlap Bart, Lee Hanshin
    Abstract:

    The Visible Integral Field Replicable Unit Spectrograph (VIRUS) is an array of at least 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET) to carry out the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic grating as its Dispersing Element that is used in first order for 350 nm to 550 nm. We discuss the test methods used to evaluate the performance of the prototype gratings, which have aided in modifying the fabrication prescription for achieving the specified batch diffraction efficiency required for HETDEX. In particular, we discuss tests in which we measure the diffraction efficiency at the nominal grating angle of incidence in VIRUS for all orders accessible to our test bench that are allowed by the grating equation. For select gratings, these tests have allowed us to account for > 90% of the incident light for wavelengths within the spectral coverage of VIRUS. The remaining light that is unaccounted for is likely being diffracted into reflective orders or being absorbed or scattered within the grating layer (for bluer wavelengths especially, the latter term may dominate the others). Finally, we discuss an apparatus that will be used to quickly verify the first order diffraction efficiency specification for the batch of at least 150 VIRUS production gratings.Comment: 18 pages, 11 figures. To be published in Proc. SPIE, 2012, "Ground-Based and Airborne Instrumentation for Astronomy IV", 8446-20

Shaojie Chen - One of the best experts on this subject based on the ideXlab platform.

  • the infrared imaging spectrograph iris for tmt volume phase holographic grating performance testing and discussion
    arXiv: Instrumentation and Methods for Astrophysics, 2014
    Co-Authors: Shaojie Chen, Elliot Meyer, James E Larkin, Etsuko Mieda, Shelley A. Wright, Anna M Moore, Jerome Maire, Luc Simard
    Abstract:

    Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential Dispersing Element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82{\mu}m (H-band) to produce a spectral resolution of 4000 and 1.19- 1.37 {\mu}m (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629{\mu}m and 1.27{\mu}m, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5 degree deviation from the Bragg angle, and 25%-28% decrease at J-band when 5{\deg} deviation from the Bragg angle.

  • The infrared imaging spectrograph (IRIS) for TMT: volume phase holographic grating performance testing and discussion
    Ground-based and Airborne Instrumentation for Astronomy V. Proc. SPIE, 2014
    Co-Authors: Shaojie Chen, Elliot Meyer, James E Larkin, Etsuko Mieda, Judith Maire, Shelley A. Wright, Anna M Moore, Luc Simard
    Abstract:

    Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential Dispersing Element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82μm (H-band) to produce a spectral resolution of 4000 and 1.19-1.37μm (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629μm and 1.27μm, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5° deviation from the Bragg angle, and 25%-28% decrease at J-band when 5° deviation from the Bragg angle.

Chonis, Taylor S. - One of the best experts on this subject based on the ideXlab platform.

  • Mass production of volume phase holographic gratings for the VIRUS spectrograph array
    'SPIE-Intl Soc Optical Eng', 2014
    Co-Authors: Chonis, Taylor S., Hill, Gary J., Clemens J. Christopher, Lee Hanshin, Frantz Amy, Tuttle, Sarah E., Adams, Joshua J., Marshall J. L., Depoy D. L., Prochaska Travis
    Abstract:

    The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its Dispersing Element. The instrument utilizes the grating in first-order for 350-550 nm. Including witness samples, a suite of 170 VPH gratings has been mass produced for VIRUS. Here, we present the design of the VIRUS VPH gratings and a discussion of their mass production. We additionally present the design and functionality of a custom apparatus that has been used to rapidly test the first-order diffraction efficiency of the gratings for various discrete wavelengths within the VIRUS spectral range. This device has been used to perform both in-situ tests to monitor the effects of adjustments to the production prescription as well as to carry out the final acceptance tests of the gratings' diffraction efficiency. Finally, we present the as-built performance results for the entire suite of VPH gratings.Comment: 16 pages, 11 figures, 2 tables. To be published in Proc. SPIE, 2014, "Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation", 9151-53. The work presented in this article follows from arXiv:1207:448

  • Methods for evaluating the performance of volume phase holographic gratings for the VIRUS spectrograph array
    'SPIE-Intl Soc Optical Eng', 2012
    Co-Authors: Chonis, Taylor S., Hill, Gary J., Clemens J. Christopher, Dunlap Bart, Lee Hanshin
    Abstract:

    The Visible Integral Field Replicable Unit Spectrograph (VIRUS) is an array of at least 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET) to carry out the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic grating as its Dispersing Element that is used in first order for 350 nm to 550 nm. We discuss the test methods used to evaluate the performance of the prototype gratings, which have aided in modifying the fabrication prescription for achieving the specified batch diffraction efficiency required for HETDEX. In particular, we discuss tests in which we measure the diffraction efficiency at the nominal grating angle of incidence in VIRUS for all orders accessible to our test bench that are allowed by the grating equation. For select gratings, these tests have allowed us to account for > 90% of the incident light for wavelengths within the spectral coverage of VIRUS. The remaining light that is unaccounted for is likely being diffracted into reflective orders or being absorbed or scattered within the grating layer (for bluer wavelengths especially, the latter term may dominate the others). Finally, we discuss an apparatus that will be used to quickly verify the first order diffraction efficiency specification for the batch of at least 150 VIRUS production gratings.Comment: 18 pages, 11 figures. To be published in Proc. SPIE, 2012, "Ground-Based and Airborne Instrumentation for Astronomy IV", 8446-20

Mertin M. - One of the best experts on this subject based on the ideXlab platform.

  • Highly efficient blazed grating with multilayer coating for tender X-ray energies
    2016
    Co-Authors: Senf F., Bijkerk Frederik, Eggenstein F., Gwalt G., Huang Qiushi, Van De Kruijs, Robbert Wilhelmus Elisabeth, Kutz O., Lemke S., Louis Eric, Mertin M.
    Abstract:

    For photon energies of 1 – 5 keV, blazed gratings with multilayer coating are ideally suited for the suppression of stray and higher orders light in grating monochromators. We developed and characterized a blazed 2000 lines/mm grating coated with a 20 period Cr/C- multilayer. The multilayer d-spacing of 7.3 nm has been adapted to the line distance of 500 nm and the blaze angle of 0.84° in order to provide highest efficiency in the photon energy range between 1.5 keV and 3 keV. Efficiency of the multilayer grating as well as the reflectance of a witness multilayer which were coated simultaneously have been measured. An efficiency of 35% was measured at 2 keV while a maximum efficiency of 55% was achieved at 4 keV. In addition, a strong suppression of higher orders was observed which makes blazed multilayer gratings a favorable Dispersing Element also for the low X-ray energy range

  • Highly efficient blazed grating with multilayer coating for tender X ray energies
    2016
    Co-Authors: Senf F., Eggenstein F., Gwalt G., Kutz O., Lemke S., Bijkerk F., Huang Q., Kruijs R., Louis E., Mertin M.
    Abstract:

    For photon energies of 1 5 keV, blazed gratings with multilayer coating are ideally suited for the suppression of stray and higher orders light in grating monochromators. We developed and characterized a blazed 2000 lines mm grating coated with a 20 period Cr C multilayer. The multilayer d spacing of 7.3 nm has been adapted to the line distance of 500 nm and the blaze angle of 0.84 in order to provide highest efficiency in the photon energy range between 1.5 keV and 3 keV. Efficiency of the multilayer grating as well as the reflectance of a witness multilayer which were coated simultaneously have been measured. An efficiency of 35 was measured at 2 keV while a maximum efficiency of 55 was achieved at 4 keV. In addition, a strong suppression of higher orders was observed which makes blazed multilayer gratings a favorable Dispersing Element also for the low X ray energy rang