The Experts below are selected from a list of 228 Experts worldwide ranked by ideXlab platform

Zhong Lin Wang - One of the best experts on this subject based on the ideXlab platform.

  • a packaged self powered system with universal connectors based on hybridized nanogenerators
    Advanced Materials, 2016
    Co-Authors: Bojing Shi, Qiang Zheng, Wen Jiang, Ling Yan, Xinxin Wang, Hong Liu, Yan Yao, Zhou Li, Zhong Lin Wang
    Abstract:

    A packaged self-powered system by hybridizing nanogenerators (PSNGS) is demonstrated. The performance of the PSNGS is tested in a biofluid and used for powering an Electronic Thermometer. Select waterproof universal connectors are designed and fabricated for energy and signal transmission. This PSNGS and the connectors can significantly advance the development of self-powered implanted medical devices and wearable/portable Electronics.

  • triboelectric nanogenerator based on fully enclosed rolling spherical structure for harvesting low frequency water wave energy
    Advanced Energy Materials, 2015
    Co-Authors: Zhong Lin Wang, Xiaofeng Wang, Fang Yi
    Abstract:

    Water waves are increasingly regarded as a promising source for large-scale energy applications. Triboelectric nanogenerators (TENGs) have been recognized as one of the most promising approaches for harvesting wave energy. This work examines a freestanding, fully enclosed TENG that encloses a rolling ball inside a rocking spherical shell. Through the optimization of materials and structural parameters, a spherical TENG of 6 cm in diameter actuated by water waves can provide a peak current of 1 μA over a wide load range from a short-circuit condition to 10 GΩ, with an instantaneous output power of up to 10 mW. A multielectrode arrangement is also studied to improve the output of the TENG under random wave motions from all directions. Moreover, at a frequency of 1.43 Hz, the wave-driven TENG can directly drive tens of LEDs and charge a series of supercapacitors to rated voltage within several hours. The stored energy can power an Electronic Thermometer for 20 min. This rolling-structured TENG is extremely lightweight, has a simple structure, and is capable of rocking on or in water to harvest wave energy; it provides an innovative and effective approach toward large-scale blue energy harvesting of oceans and lakes.

Yina Liu - One of the best experts on this subject based on the ideXlab platform.

  • triboelectric electromagnetic hybrid generator for harvesting blue energy
    Nano-micro Letters, 2018
    Co-Authors: Huiyun Shao, Ping Cheng, Ruixuan Chen, Lingjie Xie, Na Sun, Qingqing Shen, Xiaoping Chen, Qianqian Zhu, Yi Zhang, Yina Liu
    Abstract:

    Progress has been developed in harvesting low-frequency and irregular blue energy using a triboelectric–electromagnetic hybrid generator in recent years. However, the design of the high-efficiency, mechanically durable hybrid structure is still challenging. In this study, we report a fully packaged triboelectric–electromagnetic hybrid generator (TEHG), in which magnets were utilized as the trigger to drive contact–separation-mode triboelectric nanogenerators (CS-TENGs) and coupled with copper coils to operate rotary freestanding-mode electromagnetic generators (RF-EMGs). The magnet pairs that produce attraction were used to transfer the external mechanical energy to the CS-TENGs, and packaging of the CS-TENG part was achieved to protect it from the ambient environment. Under a rotatory speed of 100 rpm, the CS-TENGs enabled the TEHG to deliver an output voltage, current, and average power of 315.8 V, 44.6 μA, and ~ 90.7 μW, and the output of the RF-EMGs was 0.59 V, 1.78 mA, and 79.6 μW, respectively. The cylinder-like structure made the TEHG more easily driven by water flow and demonstrated to work as a practical power source to charge commercial capacitors. It can charge a 33 μF capacitor from 0 to 2.1 V in 84 s, and the stored energy in the capacitor can drive an Electronic Thermometer and form a self-powered water-temperature sensing system. Open image in new window

  • Triboelectric–Electromagnetic Hybrid Generator for Harvesting Blue Energy
    SpringerOpen, 2018
    Co-Authors: Huiyun Shao, Ping Cheng, Ruixuan Chen, Lingjie Xie, Na Sun, Qingqing Shen, Xiaoping Chen, Qianqian Zhu, Yi Zhang, Yina Liu
    Abstract:

    Abstract Progress has been developed in harvesting low-frequency and irregular blue energy using a triboelectric–electromagnetic hybrid generator in recent years. However, the design of the high-efficiency, mechanically durable hybrid structure is still challenging. In this study, we report a fully packaged triboelectric–electromagnetic hybrid generator (TEHG), in which magnets were utilized as the trigger to drive contact–separation-mode triboelectric nanogenerators (CS-TENGs) and coupled with copper coils to operate rotary freestanding-mode electromagnetic generators (RF-EMGs). The magnet pairs that produce attraction were used to transfer the external mechanical energy to the CS-TENGs, and packaging of the CS-TENG part was achieved to protect it from the ambient environment. Under a rotatory speed of 100 rpm, the CS-TENGs enabled the TEHG to deliver an output voltage, current, and average power of 315.8 V, 44.6 μA, and ~ 90.7 μW, and the output of the RF-EMGs was 0.59 V, 1.78 mA, and 79.6 μW, respectively. The cylinder-like structure made the TEHG more easily driven by water flow and demonstrated to work as a practical power source to charge commercial capacitors. It can charge a 33 μF capacitor from 0 to 2.1 V in 84 s, and the stored energy in the capacitor can drive an Electronic Thermometer and form a self-powered water-temperature sensing system

Guy Bogaert - One of the best experts on this subject based on the ideXlab platform.

  • tympanic infrared skin and temporal artery scan Thermometers compared with rectal measurement in children a real life assessment
    Current Therapeutic Research-clinical and Experimental, 2014
    Co-Authors: Karel Allegaert, Kristina Casteels, Ilse Van Gorp, Guy Bogaert
    Abstract:

    Abstract Introduction Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan Thermometers compared with rectal measurement to reflect core temperature. Methods Rectal (Filac 3000; Covidien, Mechelen, Belgium), tympanic (AccuSystem Genius2 Typmanic Infrared Ear Thermometer, Covidien, Mechelen, Belgium), temporal artery scan (Exergen, Exergen Corp, Watertown, Massachusetts), and infrared (ThermoFlash Contactless Medical Electronic Thermometer, Visiomedlab, Paris, France) body temperature measurements were randomly performed and readings were collected once. Temperature readings were described as median and range, and observations were compared with rectal temperature readings (using Wilcoxon, Bland-Altman, sensitivity, and specificity tests). The child's comfort was assessed by the child, parent, and nurse (using Likert scales) and ease of use was assessed by nurses (using visual analog scale). Results Based on observations in 294 (median age=3.2 years, range=0.02–17 years) children, the mean difference was 0.49°C (tympanic scan; P P P = 0.9288), respectively, when compared with rectal temperature readings. Based on visual inspection of Bland-Altman plots, all tools overestimated the temperature at lower body temperature and underestimated the temperature at higher body temperature, resulting in a sensitivity of 22% to 41% and a specificity of 98% to 100% for rectal temperatures above 38°C. The Likert scale scores and the visual analog scale scores for rectal measurement were only slightly higher when compared with the other methods. Conclusions All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive techniques overestimate lower temperatures and underestimate higher temperatures compared with rectal measurement. In our hands, temporal artery scan measurement seems to be second best, but not yet ideal.

Huiyun Shao - One of the best experts on this subject based on the ideXlab platform.

  • triboelectric electromagnetic hybrid generator for harvesting blue energy
    Nano-micro Letters, 2018
    Co-Authors: Huiyun Shao, Ping Cheng, Ruixuan Chen, Lingjie Xie, Na Sun, Qingqing Shen, Xiaoping Chen, Qianqian Zhu, Yi Zhang, Yina Liu
    Abstract:

    Progress has been developed in harvesting low-frequency and irregular blue energy using a triboelectric–electromagnetic hybrid generator in recent years. However, the design of the high-efficiency, mechanically durable hybrid structure is still challenging. In this study, we report a fully packaged triboelectric–electromagnetic hybrid generator (TEHG), in which magnets were utilized as the trigger to drive contact–separation-mode triboelectric nanogenerators (CS-TENGs) and coupled with copper coils to operate rotary freestanding-mode electromagnetic generators (RF-EMGs). The magnet pairs that produce attraction were used to transfer the external mechanical energy to the CS-TENGs, and packaging of the CS-TENG part was achieved to protect it from the ambient environment. Under a rotatory speed of 100 rpm, the CS-TENGs enabled the TEHG to deliver an output voltage, current, and average power of 315.8 V, 44.6 μA, and ~ 90.7 μW, and the output of the RF-EMGs was 0.59 V, 1.78 mA, and 79.6 μW, respectively. The cylinder-like structure made the TEHG more easily driven by water flow and demonstrated to work as a practical power source to charge commercial capacitors. It can charge a 33 μF capacitor from 0 to 2.1 V in 84 s, and the stored energy in the capacitor can drive an Electronic Thermometer and form a self-powered water-temperature sensing system. Open image in new window

  • Triboelectric–Electromagnetic Hybrid Generator for Harvesting Blue Energy
    SpringerOpen, 2018
    Co-Authors: Huiyun Shao, Ping Cheng, Ruixuan Chen, Lingjie Xie, Na Sun, Qingqing Shen, Xiaoping Chen, Qianqian Zhu, Yi Zhang, Yina Liu
    Abstract:

    Abstract Progress has been developed in harvesting low-frequency and irregular blue energy using a triboelectric–electromagnetic hybrid generator in recent years. However, the design of the high-efficiency, mechanically durable hybrid structure is still challenging. In this study, we report a fully packaged triboelectric–electromagnetic hybrid generator (TEHG), in which magnets were utilized as the trigger to drive contact–separation-mode triboelectric nanogenerators (CS-TENGs) and coupled with copper coils to operate rotary freestanding-mode electromagnetic generators (RF-EMGs). The magnet pairs that produce attraction were used to transfer the external mechanical energy to the CS-TENGs, and packaging of the CS-TENG part was achieved to protect it from the ambient environment. Under a rotatory speed of 100 rpm, the CS-TENGs enabled the TEHG to deliver an output voltage, current, and average power of 315.8 V, 44.6 μA, and ~ 90.7 μW, and the output of the RF-EMGs was 0.59 V, 1.78 mA, and 79.6 μW, respectively. The cylinder-like structure made the TEHG more easily driven by water flow and demonstrated to work as a practical power source to charge commercial capacitors. It can charge a 33 μF capacitor from 0 to 2.1 V in 84 s, and the stored energy in the capacitor can drive an Electronic Thermometer and form a self-powered water-temperature sensing system

Karel Allegaert - One of the best experts on this subject based on the ideXlab platform.

  • tympanic infrared skin and temporal artery scan Thermometers compared with rectal measurement in children a real life assessment
    Current Therapeutic Research-clinical and Experimental, 2014
    Co-Authors: Karel Allegaert, Kristina Casteels, Ilse Van Gorp, Guy Bogaert
    Abstract:

    Abstract Introduction Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan Thermometers compared with rectal measurement to reflect core temperature. Methods Rectal (Filac 3000; Covidien, Mechelen, Belgium), tympanic (AccuSystem Genius2 Typmanic Infrared Ear Thermometer, Covidien, Mechelen, Belgium), temporal artery scan (Exergen, Exergen Corp, Watertown, Massachusetts), and infrared (ThermoFlash Contactless Medical Electronic Thermometer, Visiomedlab, Paris, France) body temperature measurements were randomly performed and readings were collected once. Temperature readings were described as median and range, and observations were compared with rectal temperature readings (using Wilcoxon, Bland-Altman, sensitivity, and specificity tests). The child's comfort was assessed by the child, parent, and nurse (using Likert scales) and ease of use was assessed by nurses (using visual analog scale). Results Based on observations in 294 (median age=3.2 years, range=0.02–17 years) children, the mean difference was 0.49°C (tympanic scan; P P P = 0.9288), respectively, when compared with rectal temperature readings. Based on visual inspection of Bland-Altman plots, all tools overestimated the temperature at lower body temperature and underestimated the temperature at higher body temperature, resulting in a sensitivity of 22% to 41% and a specificity of 98% to 100% for rectal temperatures above 38°C. The Likert scale scores and the visual analog scale scores for rectal measurement were only slightly higher when compared with the other methods. Conclusions All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive techniques overestimate lower temperatures and underestimate higher temperatures compared with rectal measurement. In our hands, temporal artery scan measurement seems to be second best, but not yet ideal.