Gang Hou - One of the best experts on this subject based on the ideXlab platform.

  • Flex-rigid pleuroscopic biopsy with the SB knife Jr is a novel technique for diagnosis of malignant or benign Fibrothorax.
    Journal of Thoracic Disease, 2016
    Co-Authors: Xiao-bo Wang, Yan Yin, Yuan Miao, Ralf Eberhardt, Gang Hou, Felix J.f. Herth, Jian Kang
    Abstract:

    Diagnosing pleural effusion is challenging, especially in patients with malignant or benign Fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant Fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign Fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with Fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign Fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.

  • semi rigid thoracoscopic punch biopsy using a hybrid knife with a high pressure water jet for the diagnosis of pleural effusions
    Respiration, 2016
    Co-Authors: Yan Yin, Xiao-bo Wang, Ralf Eberhardt, Felix J.f. Herth, Jian Kang, Qiuyue Wang, Gang Hou
    Abstract:

    Semi-rigid thoracoscopy is an important technique in the definitive diagnosis of pleural diseases with high diagnostic sensitivity and specificity. Obtaining adequate samples from thickened pleura is the most important limitation of semi-rigid thoracoscopy with a standard flexible forceps (SFF) compared with rigid thoracoscopy, especially in patients with mesothelioma or benign Fibrothorax. Developing a convenient, efficient and safe biopsy technique to obtain sufficient samples from such patients is a key topic in semi-rigid thoracoscopy. The hybrid knife (HK) is an innovative design fusing high-pressure water injection and a conventional diathermic knife that can allow for the safe resection of a larger lesion during gastrointestinal endoscopic dissection. Here, we describe 3 patients with unexplained pleural effusion who underwent pleural biopsy using an HK to investigate the potential use of the HK as a new pleural biopsy device in semi-rigid thoracoscopy when pleural lesions are difficult to biopsy using an SFF. The biopsies were obtained successfully by HK, and the diagnosis followed. The sizes of the biopsies collected by HK are larger than those collected by SFF. No complications were observed. Electrocautery biopsy using an HK during semi-rigid thoracoscopy has great potential for diagnosing consistent abnormal pleuras, which are difficult to biopsy with an SFF.

Yan Yin - One of the best experts on this subject based on the ideXlab platform.

  • Flex-rigid pleuroscopic biopsy with the SB knife Jr is a novel technique for diagnosis of malignant or benign Fibrothorax.
    Journal of Thoracic Disease, 2016
    Co-Authors: Xiao-bo Wang, Yan Yin, Yuan Miao, Ralf Eberhardt, Gang Hou, Felix J.f. Herth, Jian Kang
    Abstract:

    Diagnosing pleural effusion is challenging, especially in patients with malignant or benign Fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant Fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign Fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with Fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign Fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.

  • semi rigid thoracoscopic punch biopsy using a hybrid knife with a high pressure water jet for the diagnosis of pleural effusions
    Respiration, 2016
    Co-Authors: Yan Yin, Xiao-bo Wang, Ralf Eberhardt, Felix J.f. Herth, Jian Kang, Qiuyue Wang, Gang Hou
    Abstract:

    Semi-rigid thoracoscopy is an important technique in the definitive diagnosis of pleural diseases with high diagnostic sensitivity and specificity. Obtaining adequate samples from thickened pleura is the most important limitation of semi-rigid thoracoscopy with a standard flexible forceps (SFF) compared with rigid thoracoscopy, especially in patients with mesothelioma or benign Fibrothorax. Developing a convenient, efficient and safe biopsy technique to obtain sufficient samples from such patients is a key topic in semi-rigid thoracoscopy. The hybrid knife (HK) is an innovative design fusing high-pressure water injection and a conventional diathermic knife that can allow for the safe resection of a larger lesion during gastrointestinal endoscopic dissection. Here, we describe 3 patients with unexplained pleural effusion who underwent pleural biopsy using an HK to investigate the potential use of the HK as a new pleural biopsy device in semi-rigid thoracoscopy when pleural lesions are difficult to biopsy using an SFF. The biopsies were obtained successfully by HK, and the diagnosis followed. The sizes of the biopsies collected by HK are larger than those collected by SFF. No complications were observed. Electrocautery biopsy using an HK during semi-rigid thoracoscopy has great potential for diagnosing consistent abnormal pleuras, which are difficult to biopsy with an SFF.

Felix J.f. Herth - One of the best experts on this subject based on the ideXlab platform.

  • Flex-rigid pleuroscopic biopsy with the SB knife Jr is a novel technique for diagnosis of malignant or benign Fibrothorax.
    Journal of Thoracic Disease, 2016
    Co-Authors: Xiao-bo Wang, Yan Yin, Yuan Miao, Ralf Eberhardt, Gang Hou, Felix J.f. Herth, Jian Kang
    Abstract:

    Diagnosing pleural effusion is challenging, especially in patients with malignant or benign Fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant Fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign Fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with Fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign Fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.

  • semi rigid thoracoscopic punch biopsy using a hybrid knife with a high pressure water jet for the diagnosis of pleural effusions
    Respiration, 2016
    Co-Authors: Yan Yin, Xiao-bo Wang, Ralf Eberhardt, Felix J.f. Herth, Jian Kang, Qiuyue Wang, Gang Hou
    Abstract:

    Semi-rigid thoracoscopy is an important technique in the definitive diagnosis of pleural diseases with high diagnostic sensitivity and specificity. Obtaining adequate samples from thickened pleura is the most important limitation of semi-rigid thoracoscopy with a standard flexible forceps (SFF) compared with rigid thoracoscopy, especially in patients with mesothelioma or benign Fibrothorax. Developing a convenient, efficient and safe biopsy technique to obtain sufficient samples from such patients is a key topic in semi-rigid thoracoscopy. The hybrid knife (HK) is an innovative design fusing high-pressure water injection and a conventional diathermic knife that can allow for the safe resection of a larger lesion during gastrointestinal endoscopic dissection. Here, we describe 3 patients with unexplained pleural effusion who underwent pleural biopsy using an HK to investigate the potential use of the HK as a new pleural biopsy device in semi-rigid thoracoscopy when pleural lesions are difficult to biopsy using an SFF. The biopsies were obtained successfully by HK, and the diagnosis followed. The sizes of the biopsies collected by HK are larger than those collected by SFF. No complications were observed. Electrocautery biopsy using an HK during semi-rigid thoracoscopy has great potential for diagnosing consistent abnormal pleuras, which are difficult to biopsy with an SFF.

Ralf Eberhardt - One of the best experts on this subject based on the ideXlab platform.

  • Flex-rigid pleuroscopic biopsy with the SB knife Jr is a novel technique for diagnosis of malignant or benign Fibrothorax.
    Journal of Thoracic Disease, 2016
    Co-Authors: Xiao-bo Wang, Yan Yin, Yuan Miao, Ralf Eberhardt, Gang Hou, Felix J.f. Herth, Jian Kang
    Abstract:

    Diagnosing pleural effusion is challenging, especially in patients with malignant or benign Fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant Fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign Fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with Fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign Fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.

  • semi rigid thoracoscopic punch biopsy using a hybrid knife with a high pressure water jet for the diagnosis of pleural effusions
    Respiration, 2016
    Co-Authors: Yan Yin, Xiao-bo Wang, Ralf Eberhardt, Felix J.f. Herth, Jian Kang, Qiuyue Wang, Gang Hou
    Abstract:

    Semi-rigid thoracoscopy is an important technique in the definitive diagnosis of pleural diseases with high diagnostic sensitivity and specificity. Obtaining adequate samples from thickened pleura is the most important limitation of semi-rigid thoracoscopy with a standard flexible forceps (SFF) compared with rigid thoracoscopy, especially in patients with mesothelioma or benign Fibrothorax. Developing a convenient, efficient and safe biopsy technique to obtain sufficient samples from such patients is a key topic in semi-rigid thoracoscopy. The hybrid knife (HK) is an innovative design fusing high-pressure water injection and a conventional diathermic knife that can allow for the safe resection of a larger lesion during gastrointestinal endoscopic dissection. Here, we describe 3 patients with unexplained pleural effusion who underwent pleural biopsy using an HK to investigate the potential use of the HK as a new pleural biopsy device in semi-rigid thoracoscopy when pleural lesions are difficult to biopsy using an SFF. The biopsies were obtained successfully by HK, and the diagnosis followed. The sizes of the biopsies collected by HK are larger than those collected by SFF. No complications were observed. Electrocautery biopsy using an HK during semi-rigid thoracoscopy has great potential for diagnosing consistent abnormal pleuras, which are difficult to biopsy with an SFF.

Qiuyue Wang - One of the best experts on this subject based on the ideXlab platform.

  • semi rigid thoracoscopic punch biopsy using a hybrid knife with a high pressure water jet for the diagnosis of pleural effusions
    Respiration, 2016
    Co-Authors: Yan Yin, Xiao-bo Wang, Ralf Eberhardt, Felix J.f. Herth, Jian Kang, Qiuyue Wang, Gang Hou
    Abstract:

    Semi-rigid thoracoscopy is an important technique in the definitive diagnosis of pleural diseases with high diagnostic sensitivity and specificity. Obtaining adequate samples from thickened pleura is the most important limitation of semi-rigid thoracoscopy with a standard flexible forceps (SFF) compared with rigid thoracoscopy, especially in patients with mesothelioma or benign Fibrothorax. Developing a convenient, efficient and safe biopsy technique to obtain sufficient samples from such patients is a key topic in semi-rigid thoracoscopy. The hybrid knife (HK) is an innovative design fusing high-pressure water injection and a conventional diathermic knife that can allow for the safe resection of a larger lesion during gastrointestinal endoscopic dissection. Here, we describe 3 patients with unexplained pleural effusion who underwent pleural biopsy using an HK to investigate the potential use of the HK as a new pleural biopsy device in semi-rigid thoracoscopy when pleural lesions are difficult to biopsy using an SFF. The biopsies were obtained successfully by HK, and the diagnosis followed. The sizes of the biopsies collected by HK are larger than those collected by SFF. No complications were observed. Electrocautery biopsy using an HK during semi-rigid thoracoscopy has great potential for diagnosing consistent abnormal pleuras, which are difficult to biopsy with an SFF.