The Experts below are selected from a list of 2181 Experts worldwide ranked by ideXlab platform

Gina Young - One of the best experts on this subject based on the ideXlab platform.

  • development of the international space station iss fine water mist fwm portable Fire Extinguisher
    43rd International Conference on Environmental Systems, 2013
    Co-Authors: Branelle Rodriquez, Gina Young
    Abstract:

    The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of Fire Extinguishers: a water foam Extinguisher in the Russian Segments, and a carbon dioxide Extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide Extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a Fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic Fire Extinguisher to mitigate this operational risk. The FWM PFE can extinguish a Fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific Fire standards that were developed to establish an acceptable portable Fire Extinguisher s performance.

Branelle Rodriquez - One of the best experts on this subject based on the ideXlab platform.

  • development of the international space station iss fine water mist fwm portable Fire Extinguisher
    43rd International Conference on Environmental Systems, 2013
    Co-Authors: Branelle Rodriquez, Gina Young
    Abstract:

    The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of Fire Extinguishers: a water foam Extinguisher in the Russian Segments, and a carbon dioxide Extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide Extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a Fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic Fire Extinguisher to mitigate this operational risk. The FWM PFE can extinguish a Fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific Fire standards that were developed to establish an acceptable portable Fire Extinguisher s performance.

Mohammad Handoko - One of the best experts on this subject based on the ideXlab platform.

  • Analisa Penyebab Rendahnya Kemampuan Crew dalam Penggunaan Portable Fire Extinguisher saat Pelaksanaan Fire Drill Pada MV. Vinca
    2018
    Co-Authors: Mohammad Handoko
    Abstract:

    -Tujuan pemadaman kebakaran adalah untuk menghilang api yang tak terkendali, sehingga tidak menimbulkan bahaya terhadap keselamatan jiwa maupun properti. Crew dapat dilatih dengan dilaksanakannya Fire drill (sekali dalam satu bulan). Dalam kenyataannya diatas MV. Vinca, crew yang tidak mengetahui prosedur pemadaman kebakaran yang benar, terutama dalam penggunaan portable Fire Extinguisher. Hal tersebut menjadi alasan peneliti melakukan penelitian terhadap analisa penyebab rendahnya kemampuan crew dalam penggunaan portable Fire Extinguisher saat pelaksanaan Fire drill. Melalui metode pengumpulan data yaitu dengan observasi, wawancara terstruktur, studi dokumenter, riset kepustakaan kemudian dianalisa melalui Fault Tree Analysis dan Urgency, Seriousness, Growth. Berdasarkan hasil penelitian, crew memiliki kemampuan yang rendah dalam penggunaan portable Fire Extinguisher. Hal tersebut disebabkan karena pengetahuan dan pemahaman yang kurang tentang portable Fire Extinguisher, crew tidak serius dalam pelaksanaan Fire drill dan portable Fire Extinguisher tidak layak pakai karena kurangnya perawatan yang berkala dan teratur. Dan cara mengatasinya adalah memberikan pengarahan terhadap crew tentang penggunaan beserta jenis portable Fire Extinguisher, crew harus serius dalam pelaksanaan Fire drill dan perwira yang bertanggungjawab atas peralatan FFE harus melaksanakan maintenance secara berkala dan teratur. Kata kunci: Kemampuan, Portable Fire Extinguisher, crew, Fire drill, FTA, US

  • PENILAIAN KEMAMPUAN CREW DALAM PENGGUNAAN PORTABLE Fire ECTINGUISGER SAAT PELAKSANAAN Fire DRILL PADA MV.VINCA
    2018
    Co-Authors: Mohammad Handoko
    Abstract:

    ABSTRAK Mohammad Handoko, 2018, NIT : 51145188.N, “Penilaian Kemampuan Crew dalam Penggunaan Portable Fire Extinguisher Saat Pelaksanaan Fire Drill pada MV. Vinca”, Program Diploma IV, Program Studi Nautika, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Capt. Dodik Widarbowo, M.T., M.Mar dan Pembimbing II: Adi Oktavianto, ST., MM Pencegahan bahaya kebakaran merupakan usaha yang dilakukan agar tidak terjadi penyalaan api yang tidak terkendali. Bahaya kebakaran dapat menimbulkan bahaya terhadap keselamatan jiwa ataupun harta benda. Apabila terjadi bahaya kebakaran di kapal saat kapal sedang melaksanakan suatu pelayaran di tengah laut / samudera dimana kapal sedang berlayar sendiri hanya crew kapal yang dapat memadamkan api tersebut karena tidak ada kapal disekitar kapal. Oleh karena itu, Setiap kapal harus melaksanakan Fire drill minimal sekali dalam waktu satu bulan Fire drill, crew dapat lebih familiar dengan peralatan serta fungsi dari alat - alat pemadaman kebakaran yang berada diatas kapal MV. Vinca. Dengan diadakannya Fire drill, crew mampu meningkatakan kemampuan crew dalam penggunaan Fire Extinguisher guna menunjang keselamatan dalam bekerja dilaut. Dalam kenyataannya masih banyak crew kapal yang masih belum tahu jenis alat-alat pemadam kebakaran yang berada diatas kapal, terlebih cara penggunaan dan dalam keadaan bagaimana alat tersebut digunakan. Melalui metode pengumpulan data yaitu dengan observasi, wawancara terstruktur, studi dokumenter, riset kepustakaan didapat data kemudian dianalisa melalui Fault Tree Analysis (FTA) dan Urgency, Seriousness, Growth (USG). Berdasarkan hasil penelitian, bahwa crew memiliki kemampuan yang rendah dalam penggunaan portable Fire Extinguisher. Hal tersebut disebabkan karena pengetahuan dan pemahaman yang kurang tentang portable Fire Extinguisher, crew tidak serius dalam pelaksanaan Fire drill dan portable Fire Extinguisher tidak layak pakai karena kurangnya perawatan yang berkala dan teratur Jadi cara mengatasi rendahnya kemampuan crew dalam penggunaan portable Fire Extinguisher pada MV. Vinca adalah memberikan pengarahan terhadap crew tentang penggunaan beserta jenis portable Fire Extinguisher, crew harus serius dalam pelaksanaan Fire drill dan perwira yang bertanggungjawab atas peralatan Fire fighting equipment harus melaksanakan maintenance secara berkala dan teratur. Kata kunci: Kemampuan, Portable Fire Extinguisher, crew, Fire drill, FTA, US

Clements, Anna L. - One of the best experts on this subject based on the ideXlab platform.

  • Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher
    2011
    Co-Authors: Clements, Anna L.
    Abstract:

    NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of Fire Extinguishers: a water foam Extinguisher in the Russian Segment, and a carbon dioxide Extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide Fire Extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a Fire situation. NASA has developed a filtering respirator cartridge for use in a Fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The Fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 Fire Extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a Fire without creating a large volume of air with reduced oxygen and elevated CO2. From a flight hardware design perspective, the fine water mist Fire Extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface has been under development for several years. It has gone through several design iterations, and has been part of more than 400 Fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration

  • Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher ICES Abstract
    2011
    Co-Authors: Carlile Christie, Young Gina, Graf John, Clements, Anna L.
    Abstract:

    NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of Fire Extinguishers: a water foam Extinguisher in the Russian Segment, and a carbon dioxide Extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide Fire Extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a Fire situation. NASA has developed a filtering respirator cartridge for use in a Fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The Fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 Fire Extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a Fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific Fire standards will be described which were developed to establish acceptable Extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist Fire Extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 Fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe status of the project to date, the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration

Rizki Fitriana Hambyah - One of the best experts on this subject based on the ideXlab platform.

  • EVALUASI PEMASANGAN APAR DALAM SISTEM TANGGAP DARURAT KEBAKARAN DI GEDUNG BEDAH RSUD DR. SOETOMO SURABAYA
    The Indonesian Journal of Occupational Safety and Health, 2017
    Co-Authors: Rizki Fitriana Hambyah
    Abstract:

    Fire Extinguisher is one of the active Fire protection system that is used to extinguish Fires are still small and used in emergencies, so as to prevent that no larger Fires that cause harm and even fatalities. The aim of this study was to evaluate the installation of Fire Extinguisher in a Fire emergency response system in the building surgical at Dr. Soetomo Hospital. This type of this study is evaluative research. Data were collected through observation, and measurement. Variables studied, namely the installation of Fire Extinguisher. Technique of analysis in this study is to use comparative approach to determine the suitability of the installation of a Fire Extinguisher that compared with Permenakertrans No. PER.04/MEN/1980. The approach taken were to semi quantitative to see how large the proportion of the suitability of the installation of a Fire Extinguisher in the surgical building at Dr. Soetomo Hospital. The results showed that at the Dr. Soetomo Hospital have Fire emergency response system and has been applied. Installation Fire Extinguishers in the surgical building at Dr. Soetomo Hospital generally not meet the requirements of Permenakertrans No. PER.04/MEN/1980. There still is a Fire Extinguisher in the surgical building kind of halon in Bogenvil, Cempaka, Gladiol, Herbra and Nusa Indah. There is a Fire Extinguisher expired, in the surgical building at Cempaka, Dahlia, Flamboyan and Hebra. Keywords: portable Fire Extinguisher, surgical building, Dr. Soetomo hospital