Generator-Transformer UNIT REMOTE FAULT RECORD SYSTEM BASED ON WEB
Power system technology, 2004Co-Authors: Yin XianggenAbstract:To meet the need of network based monitoring and fault recording system, combined with Web technology a remote monitoring and fault recording system for Generator-Transformer unit which possesses the structure of Windows DNA and is implemented by COM/COM+ and ASP techniques is constituted. The system is easy to maintain and expand, the publication, sharing, remote on-line control of the recorded data and the adjustment and maintenance of its equipments can be realized easily and quickly. In this system the historical information based on steady state data can offer important foundation for condition-based maintenance of the equipments in the power plants to be constructed in the future.
Liu Jian - One of the best experts on this subject based on the ideXlab platform.
-
Analysis and Improvement of Secondary Wiring and Logic Design for GE Generator-Transformer Unit Protection
Zhejiang Electric Power, 2011Co-Authors: Liu JianAbstract:This paper performs the analysis and improvement of the problems in GE Generator-Transformer unit protection enabling auxiliary power fast cutting,line section of zero-power cutting machine,Generator overexcitation protection secondary circuit wiring and logic design in Huaneng Yuhuan Power Plant.It aims to improve the protection function of Generator-Transformer units and ensures its safe operation.
-
Analysis of and Improvement on Secondary Wiring and Logic Design of GE Generator-Transformer Unit Protection
Electric Power Construction, 2011Co-Authors: Liu JianAbstract:There are many problems in the secondary wiring and logic design of GE Generator-Transformer unit protection since the four units successively putting into operation in Huaneng Yuhuan Power Plant.It is analyzed and improved about the Generator-Transformer unit protection,such as starting fast cut back of auxiliary power,zero-power triping of the line section,overexcitation protection of Generator,secondary circuit wiring and logic design.It is shown that the protection functions are more perfect,effectively ensuring the safety of power system.
Wang Wen - One of the best experts on this subject based on the ideXlab platform.
-
Configuration and Analysis of Yangcheng International Power Generation Company Limited Generator Transformer Protection
2002Co-Authors: Wang WenAbstract:Besed on actuality,it introduces configuration rules and features of Yipco's Generator Transformer protection,analysis the special characteristic of the protection,and presents some practical testing methods.
-
Some Problems with the Test of WFBZ—01 Digital Protection Device for Generator-Transformer Unit
2000Co-Authors: Wang Wen, Zhai YanAbstract:Some problems occured during the site commissioning test of WFBZ—01 digital protection device for Generator Transformer unit are analysed and the practical measures are suggested.
Ding Jun - One of the best experts on this subject based on the ideXlab platform.
-
Research on COM+ based fault recording analysis system software for Generator-Transformer set
2002Co-Authors: Ding JunAbstract:Existing fault recording analysis system software for Generator-Transformer set has some shortages, such as stand-alone mode, lack of commonality and analysis function, etc. Aiming at this, a developed system software based on COM+ is presented. In this paper, the objects and interfaces of each service component are designed, several problems in the process of component deploying are discussed, and the frame of three-layer distributed system is formed. The application of this software will improve the running personnel's ability of fault analysis and estimation, and also make good condition for the realization of distributed application and fault information networking.
-
Research on the Application of COMTRADE99 Standard in Fault Recording and Analysis Software for Generator-Transformer Set
Electric power automation equipment, 2001Co-Authors: Ding JunAbstract:The selection of data format is the first matter to consider in designing the fault recording and analysis software for Generator Transformer set. The shortage of COMTRDE91 standard in dealing with fault recording data of Generator Transformer set is indicated. With the experience in the development of fault recording and analysis software for Generator Transformer set, the full and profound research on the superiority of COMTRADE99 standard is carried out.
J. Jayachandran - One of the best experts on this subject based on the ideXlab platform.
-
Recursive Constrained Algorithms for Short Circuit and Earth Fault Protection of Generator-Transformer Unit
The International Journal of Electrical Engineering & Education, 1995Co-Authors: A. M. Basha, J. JayachandranAbstract:Recursive constrained algorithms for short circuit and earth fault protection of Generator/Transformer unit Recursive constrained protective relaying algorithms are developed for extracting 50 Hz and 150 Hz components of voltage and current signals of the Generator-Transformer unit. These frequency components are used for detecting internal short circuit and earth fault conditions of the combined unit. The proposed algorithms were satisfactorily tested for various simulated conditions of the system.
-
PC based comprehensive relaying scheme for Generator-Transformer unit
Computers & Electrical Engineering, 1995Co-Authors: A. M. Basha, J. Jayachandran, M. MuraleedharanAbstract:Abstract This paper reports the development of a comprehensive protective relaying scheme for Generator-Transformer unit using digital filters. An efficient algorithm based on the recursive constraint transfer function model of the IIR band pass filter has been developed which extracts the various frequency components such as 50, 100, and 150 Hz for realizing the protective functions such as variable bias differential logic, and earth fault protection logic for the combined unit, differential protection logic, rotor over heating relaying logic, reverse power flow relaying logic, rotor earth fault protection logic and field failure relaying logic for the Generator, differential protection logic for unit Transformer and over fluxing protection logic for the main Transformer. In addition to the above relaying functions, the proposed scheme also incorporates a voltage controlled over current relay with IDMT characteristics to give back up for the short-circuit protection for the combined unit. The proposed scheme was tested for different simulated conditions representing normal and abnormal conditions of the system using a PC-80386 computer system. The set limit for discriminating between internal fault and normal condition is considered in terms of the average value rather than RMS value of the three frequency components resulting in reduction of the arithmetical complexity and computational efforts. The proposed scheme as a whole operated satisfactorily by issuing trip signals during internal fault conditions and restraining from tripping during the external fault and normal conditions.