The Experts below are selected from a list of 11478 Experts worldwide ranked by ideXlab platform
Lawrence L Wald - One of the best experts on this subject based on the ideXlab platform.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b 1 and t 1 corrections and integrated δb 0 rx shim array
Magnetic Resonance in Medicine, 2020Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, Susie Y Huang, William A Grissom, Lawrence L WaldAbstract:PURPOSE: B1+ and T1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high-isotropic-resolution generalized slice-dithered enhanced resolution (gSlider) diffusion imaging. METHODS: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-repetition time (TR) gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multicoil integrated ΔB0 /Rx shim array and high in-plane acceleration (Rinplane = 4) achieved with virtual-coil GRAPPA were also incorporated into a 1-mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in Geometric Distortion compared to single-shot echo planar imaging (EPI). RESULTS: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global second-order shimming. One-millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. CONCLUSIONS: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high-isotropic-resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1-mm isotropic diffusion imaging with 64 diffusion directions in 20 min using a 3T clinical scanner.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b1 t1 corrections and integrated delta b0 rx shim array
arXiv: Medical Physics, 2018Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, William A Grissom, Lawrence L Wald, Kawin SetsompopAbstract:Purpose: B1+ and T1 corrections and dynamic multi-coil shimming approaches were proposed to improve the fidelity of high isotropic resolution Generalized slice dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-TR gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multi-coil integrated {\Delta}B0/Rx shim-array, and high in-plane acceleration (Rinplane=4) achieved with virtual-coil GRAPPA were also incorporated into a 1 mm isotropic resolution gSlider acquisition/reconstruction framework to achieve an 8-11 fold reduction in Geometric Distortion compared to single-shot EPI. Results: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global 2nd order shimming. 1 mm isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. Conclusions: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high isotropic resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1 mm isotropic diffusion imaging with 64 diffusion-directions in 20 minutes using a 3T clinical scanner.
Nicolas Arango - One of the best experts on this subject based on the ideXlab platform.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b 1 and t 1 corrections and integrated δb 0 rx shim array
Magnetic Resonance in Medicine, 2020Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, Susie Y Huang, William A Grissom, Lawrence L WaldAbstract:PURPOSE: B1+ and T1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high-isotropic-resolution generalized slice-dithered enhanced resolution (gSlider) diffusion imaging. METHODS: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-repetition time (TR) gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multicoil integrated ΔB0 /Rx shim array and high in-plane acceleration (Rinplane = 4) achieved with virtual-coil GRAPPA were also incorporated into a 1-mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in Geometric Distortion compared to single-shot echo planar imaging (EPI). RESULTS: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global second-order shimming. One-millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. CONCLUSIONS: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high-isotropic-resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1-mm isotropic diffusion imaging with 64 diffusion directions in 20 min using a 3T clinical scanner.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b1 t1 corrections and integrated delta b0 rx shim array
arXiv: Medical Physics, 2018Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, William A Grissom, Lawrence L Wald, Kawin SetsompopAbstract:Purpose: B1+ and T1 corrections and dynamic multi-coil shimming approaches were proposed to improve the fidelity of high isotropic resolution Generalized slice dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-TR gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multi-coil integrated {\Delta}B0/Rx shim-array, and high in-plane acceleration (Rinplane=4) achieved with virtual-coil GRAPPA were also incorporated into a 1 mm isotropic resolution gSlider acquisition/reconstruction framework to achieve an 8-11 fold reduction in Geometric Distortion compared to single-shot EPI. Results: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global 2nd order shimming. 1 mm isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. Conclusions: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high isotropic resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1 mm isotropic diffusion imaging with 64 diffusion-directions in 20 minutes using a 3T clinical scanner.
Congyu Liao - One of the best experts on this subject based on the ideXlab platform.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b 1 and t 1 corrections and integrated δb 0 rx shim array
Magnetic Resonance in Medicine, 2020Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, Susie Y Huang, William A Grissom, Lawrence L WaldAbstract:PURPOSE: B1+ and T1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high-isotropic-resolution generalized slice-dithered enhanced resolution (gSlider) diffusion imaging. METHODS: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-repetition time (TR) gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multicoil integrated ΔB0 /Rx shim array and high in-plane acceleration (Rinplane = 4) achieved with virtual-coil GRAPPA were also incorporated into a 1-mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in Geometric Distortion compared to single-shot echo planar imaging (EPI). RESULTS: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global second-order shimming. One-millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. CONCLUSIONS: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high-isotropic-resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1-mm isotropic diffusion imaging with 64 diffusion directions in 20 min using a 3T clinical scanner.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b1 t1 corrections and integrated delta b0 rx shim array
arXiv: Medical Physics, 2018Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, William A Grissom, Lawrence L Wald, Kawin SetsompopAbstract:Purpose: B1+ and T1 corrections and dynamic multi-coil shimming approaches were proposed to improve the fidelity of high isotropic resolution Generalized slice dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-TR gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multi-coil integrated {\Delta}B0/Rx shim-array, and high in-plane acceleration (Rinplane=4) achieved with virtual-coil GRAPPA were also incorporated into a 1 mm isotropic resolution gSlider acquisition/reconstruction framework to achieve an 8-11 fold reduction in Geometric Distortion compared to single-shot EPI. Results: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global 2nd order shimming. 1 mm isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. Conclusions: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high isotropic resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1 mm isotropic diffusion imaging with 64 diffusion-directions in 20 minutes using a 3T clinical scanner.
Kawin Setsompop - One of the best experts on this subject based on the ideXlab platform.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b1 t1 corrections and integrated delta b0 rx shim array
arXiv: Medical Physics, 2018Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, William A Grissom, Lawrence L Wald, Kawin SetsompopAbstract:Purpose: B1+ and T1 corrections and dynamic multi-coil shimming approaches were proposed to improve the fidelity of high isotropic resolution Generalized slice dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-TR gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multi-coil integrated {\Delta}B0/Rx shim-array, and high in-plane acceleration (Rinplane=4) achieved with virtual-coil GRAPPA were also incorporated into a 1 mm isotropic resolution gSlider acquisition/reconstruction framework to achieve an 8-11 fold reduction in Geometric Distortion compared to single-shot EPI. Results: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global 2nd order shimming. 1 mm isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. Conclusions: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high isotropic resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1 mm isotropic diffusion imaging with 64 diffusion-directions in 20 minutes using a 3T clinical scanner.
William A Grissom - One of the best experts on this subject based on the ideXlab platform.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b 1 and t 1 corrections and integrated δb 0 rx shim array
Magnetic Resonance in Medicine, 2020Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, Susie Y Huang, William A Grissom, Lawrence L WaldAbstract:PURPOSE: B1+ and T1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high-isotropic-resolution generalized slice-dithered enhanced resolution (gSlider) diffusion imaging. METHODS: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-repetition time (TR) gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multicoil integrated ΔB0 /Rx shim array and high in-plane acceleration (Rinplane = 4) achieved with virtual-coil GRAPPA were also incorporated into a 1-mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in Geometric Distortion compared to single-shot echo planar imaging (EPI). RESULTS: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global second-order shimming. One-millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. CONCLUSIONS: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high-isotropic-resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1-mm isotropic diffusion imaging with 64 diffusion directions in 20 min using a 3T clinical scanner.
-
high fidelity high isotropic resolution diffusion imaging through gslider acquisition with b1 t1 corrections and integrated delta b0 rx shim array
arXiv: Medical Physics, 2018Co-Authors: Congyu Liao, Jason P Stockmann, Qiyuan Tian, Berkin Bilgic, Nicolas Arango, Mary Kate Manhard, William A Grissom, Lawrence L Wald, Kawin SetsompopAbstract:Purpose: B1+ and T1 corrections and dynamic multi-coil shimming approaches were proposed to improve the fidelity of high isotropic resolution Generalized slice dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B1+ inhomogeneity and T1 recovery information was developed to mitigate slab-boundary artifacts in short-TR gSlider acquisitions. Slab-by-slab dynamic B0 shimming using a multi-coil integrated {\Delta}B0/Rx shim-array, and high in-plane acceleration (Rinplane=4) achieved with virtual-coil GRAPPA were also incorporated into a 1 mm isotropic resolution gSlider acquisition/reconstruction framework to achieve an 8-11 fold reduction in Geometric Distortion compared to single-shot EPI. Results: The slab-boundary artifacts were alleviated by the proposed B1+ and T1 corrections compared to the standard gSlider reconstruction pipeline for short-TR acquisitions. Dynamic shimming provided >50% reduction in Geometric Distortion compared to conventional global 2nd order shimming. 1 mm isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high Geometric fidelity using dynamic shimming. Conclusions: The proposed B1+ and T1 corrections and local-field control substantially improved the fidelity of high isotropic resolution diffusion imaging, with reduced slab-boundary artifacts and Geometric Distortion compared to conventional gSlider acquisition and reconstruction. This enabled high-fidelity whole-brain 1 mm isotropic diffusion imaging with 64 diffusion-directions in 20 minutes using a 3T clinical scanner.