  • An unusual cause of acute mitral regurgitation in TTK Chitra Heart Valve Prosthesis
    Indian Journal of Thoracic and Cardiovascular Surgery, 2021
    Co-Authors: Muthukumar Sundaram, Aayush Poddar, Ancy Robinson, Soundaravalli Balakrishnan, Muralidharan Srinivasan, Chandrasekar Padmanabhan
    Abstract:

    Structural failure of mechanical Heart Valve was a known feature when it was evolving in the 1960s and 1970s. With the advent of pyrolytic carbon and a better design, it is a rare entity with present Valves. We report a case of disc fracture leading to acute mitral regurgitation in TTK Chitra Heart Valve Prosthesis (CHVP) (TTK Healthcare Limited, India) Heart Valve, 6 years after its implantation in mitral position.

S. Harikrishnan - One of the best experts on this subject based on the ideXlab platform.

  • Hemodynamic performance evaluation of TTK Chitra Heart Valve Prosthesis in the aortic position using Doppler echocardiography.
    International journal of cardiology, 2008
    Co-Authors: Narayanan Namboodiri, Othayoth Shajeem, Jaganmohan Tharakan, R. Sankarkumar, Thomas Titus, Valaparambil K. Ajitkumar, Sivasubramonian Sivasankaran, Kavassery Mahadevan Krishnamoorthy, S. Harikrishnan
    Abstract:

    More than 15,000 patients have been implanted with TTK Chitra Heart Valve Prosthesis (CHVP), a tilting disc prosthetic Valve in various institutions in India. Though it has been in use for more than 15 years with a few follow up studies reporting excellent long term clinical results [1–3], there is scarcity of data on the normal echocardiographic parameters of this Valve. This study was planned to establish a reference for the normal Doppler echocardiographic parameters for the CHVP in aortic position with the use of transthoracic echocardiography (TTE), in a large series of patients with normally functioning Valves.

Muthukumar Sundaram - One of the best experts on this subject based on the ideXlab platform.

  • An unusual cause of acute mitral regurgitation in TTK Chitra Heart Valve Prosthesis
    Indian Journal of Thoracic and Cardiovascular Surgery, 2021
    Co-Authors: Muthukumar Sundaram, Aayush Poddar, Ancy Robinson, Soundaravalli Balakrishnan, Muralidharan Srinivasan, Chandrasekar Padmanabhan
    Abstract:

    Structural failure of mechanical Heart Valve was a known feature when it was evolving in the 1960s and 1970s. With the advent of pyrolytic carbon and a better design, it is a rare entity with present Valves. We report a case of disc fracture leading to acute mitral regurgitation in TTK Chitra Heart Valve Prosthesis (CHVP) (TTK Healthcare Limited, India) Heart Valve, 6 years after its implantation in mitral position.

Odd Geiran - One of the best experts on this subject based on the ideXlab platform.

  • Karl Viktor Hall: From In Situ Vein Bypass to the Tilting Disc Heart Valve Prosthesis
    The Annals of thoracic surgery, 2016
    Co-Authors: John-peder Escobar Kvitting, Odd Geiran
    Abstract:

    In 1977, Karl Viktor Hall implanted a novel tilting disc Heart Valve Prosthesis at Rikshospitalet in Oslo, Norway. The Medtronic-Hall Valve was known for its excellent durability and low thrombogenicity. Hall popularized the use of the great saphenous vein in situ as an arterial shunt in the 1960s, made a metal stripper to lyse vein Valves, and introduced electromagnetic flowmeters in vascular surgery. He performed the first coronary artery bypass graft in Scandinavia in 1969. Under his leadership the first Heart transplantation and the first Heart-lung transplantation were performed in Scandinavia by his successor Tor Froysaker in 1983 and 1986, respectively.

Narayanan Namboodiri - One of the best experts on this subject based on the ideXlab platform.

  • Hemodynamic performance evaluation of TTK Chitra Heart Valve Prosthesis in the aortic position using Doppler echocardiography.
    International journal of cardiology, 2008
    Co-Authors: Narayanan Namboodiri, Othayoth Shajeem, Jaganmohan Tharakan, R. Sankarkumar, Thomas Titus, Valaparambil K. Ajitkumar, Sivasubramonian Sivasankaran, Kavassery Mahadevan Krishnamoorthy, S. Harikrishnan
    Abstract:

    More than 15,000 patients have been implanted with TTK Chitra Heart Valve Prosthesis (CHVP), a tilting disc prosthetic Valve in various institutions in India. Though it has been in use for more than 15 years with a few follow up studies reporting excellent long term clinical results [1–3], there is scarcity of data on the normal echocardiographic parameters of this Valve. This study was planned to establish a reference for the normal Doppler echocardiographic parameters for the CHVP in aortic position with the use of transthoracic echocardiography (TTE), in a large series of patients with normally functioning Valves.