The Experts below are selected from a list of 303 Experts worldwide ranked by ideXlab platform

Hsien-chang Chang - One of the best experts on this subject based on the ideXlab platform.

  • Monitoring perspiration from palms of Hypohidrosis patients with a stopped-flow conductometric mini-system
    Clinica Chimica Acta, 2004
    Co-Authors: Bin-wha Chang, Shoou-jeng Yeh, Ping-ping Tsai, Hsien-chang Chang
    Abstract:

    Background: Sensitive and real-time methods are required to characterize the symptoms and resolve the complicated pathology of Hypohidrosis. Method: We constructed a conductometric humidity sensor and a stopped-flow manifold with suitable dynamic range for monitoring impaired perspiration. The mini-sensor was coated with a water-absorbing polymer of poly-(2-acrylamido-2-methylpropane sulfonate). Results: Perspiration from palms of normal individuals and Hypohidrosis patients were monitored and compared. Tangent slopes of the sensorograms were capable of discriminating Hypohidrosis patients from normal individuals. Conclusion: The conductometric min-sensor and the stopped-flow manifold were proven to be useful as a diagnostic tool for Hypohidrosis.

  • Monitoring perspiration from palms of Hypohidrosis patients with a stopped-flow conductometric mini-system.
    Clinica chimica acta; international journal of clinical chemistry, 2004
    Co-Authors: Bin-wha Chang, Shoou-jeng Yeh, Ping-ping Tsai, Hsien-chang Chang
    Abstract:

    Sensitive and real-time methods are required to characterize the symptoms and resolve the complicated pathology of Hypohidrosis. We constructed a conductometric humidity sensor and a stopped-flow manifold with suitable dynamic range for monitoring impaired perspiration. The mini-sensor was coated with a water-absorbing polymer of poly-(2-acrylamido-2-methylpropane sulfonate). Perspiration from palms of normal individuals and Hypohidrosis patients were monitored and compared. Tangent slopes of the sensorograms were capable of discriminating Hypohidrosis patients from normal individuals. The conductometric min-sensor and the stopped-flow manifold were proven to be useful as a diagnostic tool for Hypohidrosis.

Brian M. Grosberg - One of the best experts on this subject based on the ideXlab platform.

Bin-wha Chang - One of the best experts on this subject based on the ideXlab platform.

  • Monitoring perspiration from palms of Hypohidrosis patients with a stopped-flow conductometric mini-system
    Clinica Chimica Acta, 2004
    Co-Authors: Bin-wha Chang, Shoou-jeng Yeh, Ping-ping Tsai, Hsien-chang Chang
    Abstract:

    Background: Sensitive and real-time methods are required to characterize the symptoms and resolve the complicated pathology of Hypohidrosis. Method: We constructed a conductometric humidity sensor and a stopped-flow manifold with suitable dynamic range for monitoring impaired perspiration. The mini-sensor was coated with a water-absorbing polymer of poly-(2-acrylamido-2-methylpropane sulfonate). Results: Perspiration from palms of normal individuals and Hypohidrosis patients were monitored and compared. Tangent slopes of the sensorograms were capable of discriminating Hypohidrosis patients from normal individuals. Conclusion: The conductometric min-sensor and the stopped-flow manifold were proven to be useful as a diagnostic tool for Hypohidrosis.

  • Monitoring perspiration from palms of Hypohidrosis patients with a stopped-flow conductometric mini-system.
    Clinica chimica acta; international journal of clinical chemistry, 2004
    Co-Authors: Bin-wha Chang, Shoou-jeng Yeh, Ping-ping Tsai, Hsien-chang Chang
    Abstract:

    Sensitive and real-time methods are required to characterize the symptoms and resolve the complicated pathology of Hypohidrosis. We constructed a conductometric humidity sensor and a stopped-flow manifold with suitable dynamic range for monitoring impaired perspiration. The mini-sensor was coated with a water-absorbing polymer of poly-(2-acrylamido-2-methylpropane sulfonate). Perspiration from palms of normal individuals and Hypohidrosis patients were monitored and compared. Tangent slopes of the sensorograms were capable of discriminating Hypohidrosis patients from normal individuals. The conductometric min-sensor and the stopped-flow manifold were proven to be useful as a diagnostic tool for Hypohidrosis.

Marina De Tommaso - One of the best experts on this subject based on the ideXlab platform.

  • Electrophysiological study in 2 children with transient Hypohidrosis induced by topiramate.
    Clinical neuropharmacology, 2008
    Co-Authors: Lucia Margari, Patrizia Ventura, Maura Buttiglione, Anna Presicci, Elisabetta Lucarelli, Michele Sardaro, Olimpia Di Fruscolo, Marina De Tommaso
    Abstract:

    Objective: Hypohidrosis, often associated with hyperthermia, has been reported, mostly in children, as a rare and reversible adverse effect of topiramate, an anticonvulsant drug with a broad spectrum of antiepileptic activity. The aim of our study is to detect a possible skin innervation involvement asthe mechanism underlying Hypohidrosis in children treated with topiramate. Methods: A neurophysiological study has been performed on 2 children who have developed Hypohidrosis under topiramate treatment. Electrophysiologicaldata have been recorded during topiramate treatment and compared with a control group. Sympathetic skin responses have been recorded during topiramate assumption and after its discontinuation. Results: In our 2 cases with Hypohidrosis related to topiramate, electrophysiological study showed normal function of both beta and delta sensory fibers and absent sympathetic skin responses that recovered to normal after topiramate discontinuation. Conclusions: Our findings confirm that topiramate might induce a transitory specific carbonic anhydrase block at the level of sweat glands, without involvement of peripheral nervous system.

Ikuo Ohmori - One of the best experts on this subject based on the ideXlab platform.