The Experts below are selected from a list of 288 Experts worldwide ranked by ideXlab platform
Juan P Cata - One of the best experts on this subject based on the ideXlab platform.
-
image guidance based on mri for spinal interstitial laser thermotherapy technical aspects and accuracy
Journal of Neurosurgery, 2017Co-Authors: Claudio E. Tatsui, Jason R Stafford, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, Jing Li, Juan P CataAbstract:OBJECTIVEImage guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression.METHODSPatients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confir...
-
Image guidance based on MRI for spinal interstitial laser thermotherapy: technical aspects and accuracy
Journal of neurosurgery. Spine, 2017Co-Authors: Claudio E. Tatsui, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, R. Jason Stafford, Juan P CataAbstract:OBJECTIVE Image guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression. METHODS Patients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confirmed with intraoperative fluoroscopy prior to advancement into a target in the epidural space. A screenshot of its final position was saved, and then the Jamshidi Needle was exchanged for an MRI-compatible access cannula. MRI of the exact axial plane of each access cannula was obtained and compared with the corresponding screenshot saved during positioning. The discrepancy in millimeters between the trajectories was measured to evaluate accuracy of the image guidance RESULTS Thirteen individuals underwent implantation of 47 laser probes. The median absolute value of the discrepancy between the location predicted by the navigation system and the actual position of the access cannulas was 0.7 mm (range 0-3.2 mm). No injury or adverse event occurred during the procedures. CONCLUSIONS This study demonstrates the feasibility of image guidance based on MRI to perform laser interstitial thermotherapy of spinal metastasis. The authors' method permits excellent visualization of the spinal cord, improving safety and workflow during laser ablations in the epidural space. The results can be extrapolated to other indications, including biopsies or drainage of fluid collections near the spinal cord.
Claudio E. Tatsui - One of the best experts on this subject based on the ideXlab platform.
-
image guidance based on mri for spinal interstitial laser thermotherapy technical aspects and accuracy
Journal of Neurosurgery, 2017Co-Authors: Claudio E. Tatsui, Jason R Stafford, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, Jing Li, Juan P CataAbstract:OBJECTIVEImage guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression.METHODSPatients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confir...
-
Image guidance based on MRI for spinal interstitial laser thermotherapy: technical aspects and accuracy
Journal of neurosurgery. Spine, 2017Co-Authors: Claudio E. Tatsui, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, R. Jason Stafford, Juan P CataAbstract:OBJECTIVE Image guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression. METHODS Patients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confirmed with intraoperative fluoroscopy prior to advancement into a target in the epidural space. A screenshot of its final position was saved, and then the Jamshidi Needle was exchanged for an MRI-compatible access cannula. MRI of the exact axial plane of each access cannula was obtained and compared with the corresponding screenshot saved during positioning. The discrepancy in millimeters between the trajectories was measured to evaluate accuracy of the image guidance RESULTS Thirteen individuals underwent implantation of 47 laser probes. The median absolute value of the discrepancy between the location predicted by the navigation system and the actual position of the access cannulas was 0.7 mm (range 0-3.2 mm). No injury or adverse event occurred during the procedures. CONCLUSIONS This study demonstrates the feasibility of image guidance based on MRI to perform laser interstitial thermotherapy of spinal metastasis. The authors' method permits excellent visualization of the spinal cord, improving safety and workflow during laser ablations in the epidural space. The results can be extrapolated to other indications, including biopsies or drainage of fluid collections near the spinal cord.
Christoph Brochhausen - One of the best experts on this subject based on the ideXlab platform.
-
Excellent histological results in terms of articular cartilage regeneration after spheroid-based autologous chondrocyte implantation (ACI)
Knee Surgery Sports Traumatology Arthroscopy, 2020Co-Authors: David Grevenstein, Andreas Mamilos, Volker H. Schmitt, Willi Wagner, C. James Kirkpatrick, Tanja Niedermair, Christoph BrochhausenAbstract:Purpose Traumatic lesions of articular cartilage represent a crucial risk factor for osteoarthritis. Even if several strategies exist to treat such damages, the optimal solution has not yet been found. A new strategy represents the scaffold-free spheroid-based autologous chondrocyte transplantation. In this method, spheroids of chondrocytes are synthesized after chondrocyte isolation and expansion, followed by the implantation in a second intervention. Methods Fine Jamshidi-Needle biopsies from five patients (one from each patient, Ø 2 mm) treated with a spheroid-based autologous chondrocyte implantation (ACI) after traumatic lesions of the articular cartilage of the knee were analysed histologically and immunohistologically for collagen II, collagen X and aggrecan expression. The indication for a second look arthroscopy was given by arthrofibrosis or meniscus-lesions, respectively. The time between ACI and second-look arthroscopy ranged between 6 and 16 months. Results In all patients, the histological examinations revealed an avascular cartilage tissue with a homogenic extracellular matrix. The subchondral bone neither showed bleeding, necrosis nor hypertrophy. A homogenous alcian blue staining indicated high amounts of mucopolysaccharides and glycosaminoglycans. Collagen II staining was highly positive, whereas collagen X staining was negative in every patient, ruling out hypertrophic chondrocyte differentiation. In addition, intense aggrecan staining indicated a strong expression of this extracellular matrix component. Conclusion The present case series represents the first histological and immunohistological analyses of spheroid-based ACI in humans. Spheroid-based ACI revealed excellent histological results regarding the regeneration of hyaline articular cartilage. These results indicate that spheroid based ACI is a promising strategy for treating traumatic lesions of the articular cartilage of the knee.
-
Excellent histological results in terms of articular cartilage regeneration after spheroid-based autologous chondrocyte implantation (ACI).
Knee surgery sports traumatology arthroscopy : official journal of the ESSKA, 2020Co-Authors: David Grevenstein, Andreas Mamilos, C. James Kirkpatrick, Tanja Niedermair, Volker Schmitt, Willi L. Wagner, Christoph BrochhausenAbstract:Traumatic lesions of articular cartilage represent a crucial risk factor for osteoarthritis. Even if several strategies exist to treat such damages, the optimal solution has not yet been found. A new strategy represents the scaffold-free spheroid-based autologous chondrocyte transplantation. In this method, spheroids of chondrocytes are synthesized after chondrocyte isolation and expansion, followed by the implantation in a second intervention. Fine Jamshidi-Needle biopsies from five patients (one from each patient, O 2 mm) treated with a spheroid-based autologous chondrocyte implantation (ACI) after traumatic lesions of the articular cartilage of the knee were analysed histologically and immunohistologically for collagen II, collagen X and aggrecan expression. The indication for a second look arthroscopy was given by arthrofibrosis or meniscus-lesions, respectively. The time between ACI and second-look arthroscopy ranged between 6 and 16 months. In all patients, the histological examinations revealed an avascular cartilage tissue with a homogenic extracellular matrix. The subchondral bone neither showed bleeding, necrosis nor hypertrophy. A homogenous alcian blue staining indicated high amounts of mucopolysaccharides and glycosaminoglycans. Collagen II staining was highly positive, whereas collagen X staining was negative in every patient, ruling out hypertrophic chondrocyte differentiation. In addition, intense aggrecan staining indicated a strong expression of this extracellular matrix component. The present case series represents the first histological and immunohistological analyses of spheroid-based ACI in humans. Spheroid-based ACI revealed excellent histological results regarding the regeneration of hyaline articular cartilage. These results indicate that spheroid based ACI is a promising strategy for treating traumatic lesions of the articular cartilage of the knee.
Dima Suki - One of the best experts on this subject based on the ideXlab platform.
-
image guidance based on mri for spinal interstitial laser thermotherapy technical aspects and accuracy
Journal of Neurosurgery, 2017Co-Authors: Claudio E. Tatsui, Jason R Stafford, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, Jing Li, Juan P CataAbstract:OBJECTIVEImage guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression.METHODSPatients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confir...
-
Image guidance based on MRI for spinal interstitial laser thermotherapy: technical aspects and accuracy
Journal of neurosurgery. Spine, 2017Co-Authors: Claudio E. Tatsui, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, R. Jason Stafford, Juan P CataAbstract:OBJECTIVE Image guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression. METHODS Patients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confirmed with intraoperative fluoroscopy prior to advancement into a target in the epidural space. A screenshot of its final position was saved, and then the Jamshidi Needle was exchanged for an MRI-compatible access cannula. MRI of the exact axial plane of each access cannula was obtained and compared with the corresponding screenshot saved during positioning. The discrepancy in millimeters between the trajectories was measured to evaluate accuracy of the image guidance RESULTS Thirteen individuals underwent implantation of 47 laser probes. The median absolute value of the discrepancy between the location predicted by the navigation system and the actual position of the access cannulas was 0.7 mm (range 0-3.2 mm). No injury or adverse event occurred during the procedures. CONCLUSIONS This study demonstrates the feasibility of image guidance based on MRI to perform laser interstitial thermotherapy of spinal metastasis. The authors' method permits excellent visualization of the spinal cord, improving safety and workflow during laser ablations in the epidural space. The results can be extrapolated to other indications, including biopsies or drainage of fluid collections near the spinal cord.
Clarissa Nóbrega Gambarra Nascimento - One of the best experts on this subject based on the ideXlab platform.
-
image guidance based on mri for spinal interstitial laser thermotherapy technical aspects and accuracy
Journal of Neurosurgery, 2017Co-Authors: Claudio E. Tatsui, Jason R Stafford, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, Jing Li, Juan P CataAbstract:OBJECTIVEImage guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression.METHODSPatients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confir...
-
Image guidance based on MRI for spinal interstitial laser thermotherapy: technical aspects and accuracy
Journal of neurosurgery. Spine, 2017Co-Authors: Claudio E. Tatsui, Clarissa Nóbrega Gambarra Nascimento, Dima Suki, Laurence D Rhines, Amol J Ghia, Jonathan G. Thomas, Behrang Amini, R. Jason Stafford, Juan P CataAbstract:OBJECTIVE Image guidance for spinal procedures is based on 3D-fluoroscopy or CT, which provide poor visualization of soft tissues, including the spinal cord. To overcome this limitation, the authors developed a method to register intraoperative MRI (iMRI) of the spine into a neuronavigation system, allowing excellent visualization of the spinal cord. This novel technique improved the accuracy in the deployment of laser interstitial thermal therapy probes for the treatment of metastatic spinal cord compression. METHODS Patients were positioned prone on the MRI table under general anesthesia. Fiducial markers were applied on the skin of the back, and a plastic cradle was used to support the MRI coil. T2-weighted MRI sequences of the region of interest were exported to a standard navigation system. A reference array was sutured to the skin, and surface matching of the fiducial markers was performed. A navigated Jamshidi Needle was advanced until contact was made with the dorsal elements; its position was confirmed with intraoperative fluoroscopy prior to advancement into a target in the epidural space. A screenshot of its final position was saved, and then the Jamshidi Needle was exchanged for an MRI-compatible access cannula. MRI of the exact axial plane of each access cannula was obtained and compared with the corresponding screenshot saved during positioning. The discrepancy in millimeters between the trajectories was measured to evaluate accuracy of the image guidance RESULTS Thirteen individuals underwent implantation of 47 laser probes. The median absolute value of the discrepancy between the location predicted by the navigation system and the actual position of the access cannulas was 0.7 mm (range 0-3.2 mm). No injury or adverse event occurred during the procedures. CONCLUSIONS This study demonstrates the feasibility of image guidance based on MRI to perform laser interstitial thermotherapy of spinal metastasis. The authors' method permits excellent visualization of the spinal cord, improving safety and workflow during laser ablations in the epidural space. The results can be extrapolated to other indications, including biopsies or drainage of fluid collections near the spinal cord.