The Experts below are selected from a list of 8322 Experts worldwide ranked by ideXlab platform
Mark Rehkamper - One of the best experts on this subject based on the ideXlab platform.
-
evaluation of optimized procedures for high precision lead isotope analyses of seawater by multiple collector inductively coupled plasma mass spectrometry
Analytical Chemistry, 2020Co-Authors: Alex M Griffiths, Hollie Packman, Yeelap Leung, Barry J Coles, Katharina Kreissig, Susan H Little, Tina Van De Flierdt, Mark RehkamperAbstract:The application of Pb isotopes to Marine Geochemistry is currently hindered by challenges associated with the analysis of Pb isotopes in seawater. The current study evaluates the performance of multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements of seawater Pb isotope compositions following Pb separation by either solid-phase extraction with Nobias Chelate PA-1 resin or coprecipitation with Mg(OH)2 and using either a Pb double spike or external normalization to Tl for mass bias correction. The four analytical combinations achieve results of similar quality when measuring 1-7 ng of seawater Pb, with reproducibilities (two standard deviations, 2SD) of 100-1200 ppm for 206Pb/207Pb and 208Pb/207Pb and 300-1700 ppm for ratios involving the minor 204Pb isotope. All four procedures enable significantly improved sample throughput compared to an established thermal ionization mass spectrometry (TIMS) double-spike method and produce unbiased seawater Pb isotope compositions with similar or improved precision. Nobias extraction is preferable to coprecipitation due to its greater analytical throughput and suitability for analyses of large seawater samples with high Si(OH)4 contents. The most accurate Pb isotope data are produced following Nobias extraction and double-spike correction as such analyses are least susceptible to matrix effects. However, Nobias extraction with Tl normalization constitutes an attractive alternative as, unlike the double-spike procedure, only a single mass spectrometric measurement is required, which improves analytical throughput and optimizes Pb consumption for analysis. Despite the advantages of solid-phase extraction, coprecipitation represents a useful Pb separation technique for samples with low to moderate Si contents as it is inexpensive, simple to implement, and the data are only marginally less accurate, especially when combined with a Pb double spike for mass bias correction.
-
applications of multiple collector icpms to cosmochemistry Geochemistry and paleoceanography
Geochimica et Cosmochimica Acta, 1998Co-Authors: Alex N Halliday, Derchuen Lee, John N Christensen, Mark Rehkamper, Xiaozhong Luo, Chris M Hall, C J Ballentine, Thomas Pettke, Claudine H StirlingAbstract:Multiple collector-inductively coupled plasma mass spectrometry (MC-ICPMS) is a new technique for the measurement of isotopic compositions at high precision, and is of great relevance to planetary, earth, ocean, and environmental sciences. The method combines the outstanding ionization efficiency of the ICP source with the superior peak shapes achievable from the ion optical focal plane of a large dispersion magnetic sector mass spectrometer, utilizing simultaneous multiple collection to achieve the most precise isotopic measurements yet made for many elements—particularly those with high first ionization potential. The addition of a laser facilitates studies for which spatial resolution is required. This method is still in its infancy, yet diverse applications have already led to a number of important scientific developments. Here we review some of these accomplishments and the potential for further work. The Lu-Hf isotopic system, for many years considered analytically challenging, is now relatively straightforward and offers great promise in fields as diverse as garnet geochronology, hydrothermal fluxes to the oceans, and crustal evolution. The age of the Earth’s core, the Moon, and Mars have been measured using a new short-lived chronometer 182Hf-182W. Other such new chronometers will follow. High precision isotope dilution measurements of the Earth’s inventory of many poorly understood elements such as In, Cd, Te, and the platinum group elements are providing tests for models for the accretion of the inner solar system. The small natural isotopic variations in elements such as Cu and Zn, produced by mass dependent fractionation, are now measurable at high precision with this method, and entirely new fields of stable isotope Geochemistry can be developed. Similarly, measurements of small nucleosynthetic isotopic anomalies should be made easier for some elements. Measurements of U and Th isotopic compositions at very high sensitivity and reproducibility are now possible, allowing the development of higher resolution Quaternary geochronology. Finally, using laser ablation, the first precise in situ Sr, Hf, W, and Pb isotopic measurements have been made in natural materials, opening up a range of microanalytical isotopic studies in petrology and Marine Geochemistry. MC-ICPMS offers exciting times ahead in areas well beyond the bounds of Geochemistry. Indeed, MC-ICPMS is likely to become the method of choice for many isotopic measurements because it is a more user friendly and efficient method for the acquisition of high precision data. It is also much more versatile, permitting elements to be measured that were previously considered intractable, and allowing the acquisition of data in situ, all with a single mass spectrometer. The limiting factor on the sensitivity is the transmission which is ≤2% for all instruments thus far designed. If it is found possible to improve the transmission still further, thermal ionization mass spectrometry, the technique that has, thus far, provided the high precision measurements necessary for most of the vast field of radiogenic isotope Geochemistry, may be relegated to specialized applications.
Claudine H Stirling - One of the best experts on this subject based on the ideXlab platform.
-
applications of multiple collector icpms to cosmochemistry Geochemistry and paleoceanography
Geochimica et Cosmochimica Acta, 1998Co-Authors: Alex N Halliday, Derchuen Lee, John N Christensen, Mark Rehkamper, Xiaozhong Luo, Chris M Hall, C J Ballentine, Thomas Pettke, Claudine H StirlingAbstract:Multiple collector-inductively coupled plasma mass spectrometry (MC-ICPMS) is a new technique for the measurement of isotopic compositions at high precision, and is of great relevance to planetary, earth, ocean, and environmental sciences. The method combines the outstanding ionization efficiency of the ICP source with the superior peak shapes achievable from the ion optical focal plane of a large dispersion magnetic sector mass spectrometer, utilizing simultaneous multiple collection to achieve the most precise isotopic measurements yet made for many elements—particularly those with high first ionization potential. The addition of a laser facilitates studies for which spatial resolution is required. This method is still in its infancy, yet diverse applications have already led to a number of important scientific developments. Here we review some of these accomplishments and the potential for further work. The Lu-Hf isotopic system, for many years considered analytically challenging, is now relatively straightforward and offers great promise in fields as diverse as garnet geochronology, hydrothermal fluxes to the oceans, and crustal evolution. The age of the Earth’s core, the Moon, and Mars have been measured using a new short-lived chronometer 182Hf-182W. Other such new chronometers will follow. High precision isotope dilution measurements of the Earth’s inventory of many poorly understood elements such as In, Cd, Te, and the platinum group elements are providing tests for models for the accretion of the inner solar system. The small natural isotopic variations in elements such as Cu and Zn, produced by mass dependent fractionation, are now measurable at high precision with this method, and entirely new fields of stable isotope Geochemistry can be developed. Similarly, measurements of small nucleosynthetic isotopic anomalies should be made easier for some elements. Measurements of U and Th isotopic compositions at very high sensitivity and reproducibility are now possible, allowing the development of higher resolution Quaternary geochronology. Finally, using laser ablation, the first precise in situ Sr, Hf, W, and Pb isotopic measurements have been made in natural materials, opening up a range of microanalytical isotopic studies in petrology and Marine Geochemistry. MC-ICPMS offers exciting times ahead in areas well beyond the bounds of Geochemistry. Indeed, MC-ICPMS is likely to become the method of choice for many isotopic measurements because it is a more user friendly and efficient method for the acquisition of high precision data. It is also much more versatile, permitting elements to be measured that were previously considered intractable, and allowing the acquisition of data in situ, all with a single mass spectrometer. The limiting factor on the sensitivity is the transmission which is ≤2% for all instruments thus far designed. If it is found possible to improve the transmission still further, thermal ionization mass spectrometry, the technique that has, thus far, provided the high precision measurements necessary for most of the vast field of radiogenic isotope Geochemistry, may be relegated to specialized applications.
Alex N Halliday - One of the best experts on this subject based on the ideXlab platform.
-
applications of multiple collector icpms to cosmochemistry Geochemistry and paleoceanography
Geochimica et Cosmochimica Acta, 1998Co-Authors: Alex N Halliday, Derchuen Lee, John N Christensen, Mark Rehkamper, Xiaozhong Luo, Chris M Hall, C J Ballentine, Thomas Pettke, Claudine H StirlingAbstract:Multiple collector-inductively coupled plasma mass spectrometry (MC-ICPMS) is a new technique for the measurement of isotopic compositions at high precision, and is of great relevance to planetary, earth, ocean, and environmental sciences. The method combines the outstanding ionization efficiency of the ICP source with the superior peak shapes achievable from the ion optical focal plane of a large dispersion magnetic sector mass spectrometer, utilizing simultaneous multiple collection to achieve the most precise isotopic measurements yet made for many elements—particularly those with high first ionization potential. The addition of a laser facilitates studies for which spatial resolution is required. This method is still in its infancy, yet diverse applications have already led to a number of important scientific developments. Here we review some of these accomplishments and the potential for further work. The Lu-Hf isotopic system, for many years considered analytically challenging, is now relatively straightforward and offers great promise in fields as diverse as garnet geochronology, hydrothermal fluxes to the oceans, and crustal evolution. The age of the Earth’s core, the Moon, and Mars have been measured using a new short-lived chronometer 182Hf-182W. Other such new chronometers will follow. High precision isotope dilution measurements of the Earth’s inventory of many poorly understood elements such as In, Cd, Te, and the platinum group elements are providing tests for models for the accretion of the inner solar system. The small natural isotopic variations in elements such as Cu and Zn, produced by mass dependent fractionation, are now measurable at high precision with this method, and entirely new fields of stable isotope Geochemistry can be developed. Similarly, measurements of small nucleosynthetic isotopic anomalies should be made easier for some elements. Measurements of U and Th isotopic compositions at very high sensitivity and reproducibility are now possible, allowing the development of higher resolution Quaternary geochronology. Finally, using laser ablation, the first precise in situ Sr, Hf, W, and Pb isotopic measurements have been made in natural materials, opening up a range of microanalytical isotopic studies in petrology and Marine Geochemistry. MC-ICPMS offers exciting times ahead in areas well beyond the bounds of Geochemistry. Indeed, MC-ICPMS is likely to become the method of choice for many isotopic measurements because it is a more user friendly and efficient method for the acquisition of high precision data. It is also much more versatile, permitting elements to be measured that were previously considered intractable, and allowing the acquisition of data in situ, all with a single mass spectrometer. The limiting factor on the sensitivity is the transmission which is ≤2% for all instruments thus far designed. If it is found possible to improve the transmission still further, thermal ionization mass spectrometry, the technique that has, thus far, provided the high precision measurements necessary for most of the vast field of radiogenic isotope Geochemistry, may be relegated to specialized applications.
Chenfeng You - One of the best experts on this subject based on the ideXlab platform.
-
a review on the determination of isotope ratios of boron with mass spectrometry
Mass Spectrometry Reviews, 2017Co-Authors: Suresh K Aggarwal, Chenfeng YouAbstract:The present review discusses different mass spectrometric techniques-viz, thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICPMS), and secondary ion mass spectrometry (SIMS)-used to determine 11 B/10 B isotope ratio, and concentration of boron required for various applications in earth sciences, Marine Geochemistry, nuclear technology, environmental, and agriculture sciences, etc. The details of the techniques-P-TIMS, which uses Cs2 BO2+ , N-TIMS, which uses BO2- , and MC-ICPMS, which uses B+ ions for bulk analysis or B- and B+ ions for in situ micro-analysis with SIMS-are highlighted. The capabilities, advantages, limitations, and problems in each mass spectrometric technique are summarized. The results of international interlaboratory comparison experiments conducted at different times are summarized. The certified isotopic reference materials available for boron are also listed. Recent developments in laser ablation (LA) ICPMS and QQQ-ICPMS for solids analysis and MS/MS analysis, respectively, are included. The different aspects of sample preparation and analytical chemistry of boron are summarized. Finally, the future requirements of boron isotope ratios for future applications are also given. Presently, MC-ICPMS provides the best precision and accuracy (0.2-0.4‰) on isotope ratio measurements, whereas N-TIMS holds the potential to analyze smallest amount of boron, but has the issue of bias (+2‰ to 4‰) which needs further investigations. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:499-519, 2017.
Alex M Griffiths - One of the best experts on this subject based on the ideXlab platform.
-
evaluation of optimized procedures for high precision lead isotope analyses of seawater by multiple collector inductively coupled plasma mass spectrometry
Analytical Chemistry, 2020Co-Authors: Alex M Griffiths, Hollie Packman, Yeelap Leung, Barry J Coles, Katharina Kreissig, Susan H Little, Tina Van De Flierdt, Mark RehkamperAbstract:The application of Pb isotopes to Marine Geochemistry is currently hindered by challenges associated with the analysis of Pb isotopes in seawater. The current study evaluates the performance of multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements of seawater Pb isotope compositions following Pb separation by either solid-phase extraction with Nobias Chelate PA-1 resin or coprecipitation with Mg(OH)2 and using either a Pb double spike or external normalization to Tl for mass bias correction. The four analytical combinations achieve results of similar quality when measuring 1-7 ng of seawater Pb, with reproducibilities (two standard deviations, 2SD) of 100-1200 ppm for 206Pb/207Pb and 208Pb/207Pb and 300-1700 ppm for ratios involving the minor 204Pb isotope. All four procedures enable significantly improved sample throughput compared to an established thermal ionization mass spectrometry (TIMS) double-spike method and produce unbiased seawater Pb isotope compositions with similar or improved precision. Nobias extraction is preferable to coprecipitation due to its greater analytical throughput and suitability for analyses of large seawater samples with high Si(OH)4 contents. The most accurate Pb isotope data are produced following Nobias extraction and double-spike correction as such analyses are least susceptible to matrix effects. However, Nobias extraction with Tl normalization constitutes an attractive alternative as, unlike the double-spike procedure, only a single mass spectrometric measurement is required, which improves analytical throughput and optimizes Pb consumption for analysis. Despite the advantages of solid-phase extraction, coprecipitation represents a useful Pb separation technique for samples with low to moderate Si contents as it is inexpensive, simple to implement, and the data are only marginally less accurate, especially when combined with a Pb double spike for mass bias correction.