The Experts below are selected from a list of 8580 Experts worldwide ranked by ideXlab platform
Pankaj Mathur - One of the best experts on this subject based on the ideXlab platform.
-
Historical TB treatment—Plombage
QJM: An International Journal of Medicine, 2017Co-Authors: Vinod Namana, Rajeswer Sarasam, Sushilkumar Satish Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
-
historical tb treatment plombage
QJM: An International Journal of Medicine, 2016Co-Authors: Vinod Namana, Rajeswer Sarasam, Sanjay Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
Vinod Namana - One of the best experts on this subject based on the ideXlab platform.
-
Historical TB treatment—Plombage
QJM: An International Journal of Medicine, 2017Co-Authors: Vinod Namana, Rajeswer Sarasam, Sushilkumar Satish Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
-
historical tb treatment plombage
QJM: An International Journal of Medicine, 2016Co-Authors: Vinod Namana, Rajeswer Sarasam, Sanjay Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
Jayesh Dhanani - One of the best experts on this subject based on the ideXlab platform.
-
increasing Ventilator surge capacity in covid 19 pandemic design manufacture and in vitro in vivo testing in anaesthetized healthy pigs of a rapid prototyped Mechanical Ventilator
BMC Research Notes, 2020Co-Authors: Jayesh Dhanani, George Pang, Jason Pincus, Benjamin J Ahern, Wendy Goodwin, Nicholas R Cowling, Grant WhittenAbstract:The advent of new technologies has made it possible to explore alternative Ventilator manufacturing to meet the worldwide shortfall for Mechanical Ventilators especially in pandemics. We describe a method using rapid prototyping technologies to create an electro-Mechanical Ventilator in a cost effective, timely manner and provide results of testing using an in vitro–in vivo testing model. Rapid prototyping technologies (3D printing and 2D cutting) were used to create a modular Ventilator. The artificial manual breathing unit (AMBU) bag connected to wall oxygen source using a flow meter was used as air reservoir. Controlled variables include respiratory rate, tidal volume and inspiratory: expiratory (I:E) ratio. In vitro testing and In vivo testing in the pig model demonstrated comparable Mechanical efficiency of the test Ventilator to that of standard Ventilator but showed the material limits of 3D printed gears. Improved gear design resulted in better Ventilator durability whilst reducing manufacturing time (< 2-h). The entire cost of manufacture of Ventilator was estimated at 300 Australian dollars. A cost-effective novel rapid prototyped Ventilator for use in patients with respiratory failure was developed in < 2-h and was effective in anesthetized, healthy pig model.
Rajeswer Sarasam - One of the best experts on this subject based on the ideXlab platform.
-
Historical TB treatment—Plombage
QJM: An International Journal of Medicine, 2017Co-Authors: Vinod Namana, Rajeswer Sarasam, Sushilkumar Satish Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
-
historical tb treatment plombage
QJM: An International Journal of Medicine, 2016Co-Authors: Vinod Namana, Rajeswer Sarasam, Sanjay Gupta, Pankaj MathurAbstract:An 82-year-old man with a history of pulmonary tuberculosis (TB) treated with Plombage, hypertension and hyperlipidemia was admitted to hospital for severe community-acquired pneumonia. He was admitted to medical intensive care unit, treated with intravenous hydration, antibiotics and Mechanical Ventilator support. The patient’s subsequent course was uneventful and was discharged home. Patient’s anteroposterior x-ray of the chest and computed tomography of the chest …
Jonathan G. Hardman - One of the best experts on this subject based on the ideXlab platform.
-
Optimization of Mechanical Ventilator Settings for Pulmonary Disease States
IEEE Transactions on Biomedical Engineering, 2013Co-Authors: Prathyush P Menon, Jonathan G. Hardman, Declan G. BatesAbstract:The selection of Mechanical Ventilator settings that ensure adequate oxygenation and carbon dioxide clearance while minimizing the risk of Ventilator-associated lung injury (VALI) is a significant challenge for intensive-care clinicians. Current guidelines are largely based on previous experience combined with recommendations from a limited number of in vivo studies whose data are typically more applicable to populations than to individuals suffering from particular diseases of the lung. By combining validated computational models of pulmonary pathophysiology with global optimization algorithms, we generate in silico experiments to examine current practice and uncover optimal combinations of Ventilator settings for individual patient and disease states. Formulating the problem as a multiobjective, multivariable constrained optimization problem, we compute settings of tidal volume, ventilation rate, inspiratory/expiratory ratio, positive end-expiratory pressure and inspired fraction of oxygen that optimally manage the tradeoffs between ensuring adequate oxygenation and carbon dioxide clearance and minimizing the risk of VALI for different pulmonary disease scenarios.
-
Accuracy of predicting arterial blood gases following Mechanical Ventilator adjustment
Critical Care, 2010Co-Authors: Hajed M Al-otaibi, Ravi Mahajan, Nigel M. Bedforth, Jonathan G. HardmanAbstract:Clinicians adjust Mechanical Ventilator (MV) in critical care units to optimise arterial blood gases (ABG). The present study evaluates their accuracy in predicting ABG values following MV adjustment.
-
Characterization of the Mechanical Ventilator adjustment process
Critical Care, 2009Co-Authors: Hajed M Al-otaibi, Jonathan G. Hardman, Ravi MahajanAbstract:The aim of the present study was to gain insight into the Mechanical Ventilator adjustment process, particularly events that prompt clinicians to adjust the Ventilator, the indications, considerations, and methods used to assess the successfulness of the adjustment episode.