The Experts below are selected from a list of 18 Experts worldwide ranked by ideXlab platform
P G H Uges - One of the best experts on this subject based on the ideXlab platform.
-
the Mollier Diagram in theory and practice part 3 examples on calculation of dew point cooling het MollierDiagram in theorie en praktijk deel 3 rekenvoorbeelden dauwpuntkoeling
Koude en Luchtbehandeling, 2007Co-Authors: H J L Kouwenhoven, H T Huizinga, N R Bootsveld, M Janssen, P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.
-
the Mollier Diagram in theory and practice part 2 evaporative indirect static dew point cooling and the Mollier Diagram het MollierDiagram in theorie en praktijk deel 2 verdampingskoeling verklaard vanuit het MollierDiagram
Koude en Luchtbehandeling, 2007Co-Authors: P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.
-
the Mollier Diagram in theory and practice part 1 the Mollier Diagram het MollierDiagram in theorie en praktijk deel 1 het MollierDiagram
Koude en Luchtbehandeling, 2007Co-Authors: P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.
H J L Kouwenhoven - One of the best experts on this subject based on the ideXlab platform.
-
the Mollier Diagram in theory and practice part 3 examples on calculation of dew point cooling het MollierDiagram in theorie en praktijk deel 3 rekenvoorbeelden dauwpuntkoeling
Koude en Luchtbehandeling, 2007Co-Authors: H J L Kouwenhoven, H T Huizinga, N R Bootsveld, M Janssen, P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.
Kangchol Mun - One of the best experts on this subject based on the ideXlab platform.
-
use of the international association for the properties of water and steam iapws formulations iapws 95 iapws if97 making of Mollier Diagram and t s Diagram of water and steam
Thermal science and engineering, 2020Co-Authors: Cholmin Kim, Hun Kim, Kangchol MunAbstract:Abstract It is very important to correctly calculate the thermodynamic properties of water and steam needed for design and operation of the main equipment of the power industry such as boilers and steam turbines. On the other hand, the Mollier Diagram and T-s Diagram of water and steam are widely used to study or review thermodynamic cycles as well as expansion processes of steam turbines and steam power equipment in the power industry. Presented in this paper are the method and procedures to exactly construct the Diagrams. The Diagrams involve several lines, including the saturation line, and constant pressure, temperature and vapor fraction lines. In the paper, a method is proposed for correctly calculating other thermodynamic properties of saturated liquid water and water vapor in saturation line of near-critical region by using the basic equation of region 3 of IAPWS-IF97 and iteration. Then, the procedures to plot the lines are presented by combining the method with IAPWS-95 and IAPWS-IF97, and the Mollier Diagram and T-s Diagram made in MS-Excel are shown. The method and procedures in the paper can be used not only in making the Mollier Diagram, T-s Diagram and steam tables, but also in accurately calculating the thermodynamic properties of saturated liquid water and water vapor.
H T Huizinga - One of the best experts on this subject based on the ideXlab platform.
-
the Mollier Diagram in theory and practice part 3 examples on calculation of dew point cooling het MollierDiagram in theorie en praktijk deel 3 rekenvoorbeelden dauwpuntkoeling
Koude en Luchtbehandeling, 2007Co-Authors: H J L Kouwenhoven, H T Huizinga, N R Bootsveld, M Janssen, P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.
N R Bootsveld - One of the best experts on this subject based on the ideXlab platform.
-
the Mollier Diagram in theory and practice part 3 examples on calculation of dew point cooling het MollierDiagram in theorie en praktijk deel 3 rekenvoorbeelden dauwpuntkoeling
Koude en Luchtbehandeling, 2007Co-Authors: H J L Kouwenhoven, H T Huizinga, N R Bootsveld, M Janssen, P G H UgesAbstract:The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier Diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het MollierDiagram.