The Experts below are selected from a list of 303 Experts worldwide ranked by ideXlab platform
Jochen Schröder - One of the best experts on this subject based on the ideXlab platform.
-
Reconfigurable SDM optical vector Network Analyzer
OFC 2014, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
OFC - Reconfigurable SDM Optical Vector Network Analyzer
Optical Fiber Communication Conference, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
reconfigurable spatially diverse optical vector Network Analyzer
Optics Express, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring the partial or complete mode transfer matrix of a system as a function of wavelength in an arbitrary mode basis using single or multiple sweeps.
Z. Skvor - One of the best experts on this subject based on the ideXlab platform.
-
Seven State PTP for Vector Network Analyzer
2005Co-Authors: Vadim Zavodny, K. Hoffmann, Z. SkvorAbstract:A new, seven-state switched perturbation two- port (PTP) for vector reflection measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octaves. Good agreement with data ob- tained using a precise vector Network Analyzer was achieved. The new calibration method for the PTP was designed and tested on real measured data.
-
7 state PTP for vector Network Analyzer
65th ARFTG Conference Digest 2005. Spring 2005, 2005Co-Authors: Vadim Zavodny, K. Hoffmann, Z. SkvorAbstract:A new, 7 state switched perturbation two-port (PTP) for vector measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octave. Good agreement with data obtained using a precise vector Network Analyzer was achieved.
-
A novel vector Network Analyzer
1998 IEEE MTT-S International Microwave Symposium Digest (Cat. No.98CH36192), 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for perturbation two-port vector Network Analyzer is presented. It consists of a variable perturbation two-port placed between a device under test and a scalar Network Analyzer. A measured vector reflection coefficient is determined on the basis of amplitude only readings. A full correction of systematic errors is possible. The new principle was experimentally confirmed in the frequency band up to 14 GHz.
-
Calibration of the PTP vector Network Analyzer
12th International Conference on Microwaves and Radar. MIKON-98. Conference Proceedings (IEEE Cat. No.98EX195), 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for perturbation two-port vector Network Analyzer (PTP VNA) is presented. PTP VNA consists of a variable perturbation two-port (PTP) placed between a device under test (DUT) and a scalar Network Analyzer (SNA). A vector reflection coefficient of the DUT is determined on the basis of amplitude only measurements. A full correction of SNA systematic errors is possible. In principle it may be used up to millimetre and submillimetre frequency bands.
-
A novel vector Network Analyzer
IEEE Transactions on Microwave Theory and Techniques, 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for a perturbation two-port vector Network Analyzer is presented. It consists of a variable perturbation two-port placed between a device-under-test and a scalar Network Analyzer. A measured vector reflection coefficient is determined on the basis of amplitude-only measurements. A full correction of systematic errors is possible. The new principle was experimentally confirmed in the frequency band up to 14 GHz. The results enable prediction of an add-on for scalar Analyzers, enabling vector measurements.
Joel Carpenter - One of the best experts on this subject based on the ideXlab platform.
-
Reconfigurable SDM optical vector Network Analyzer
OFC 2014, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
OFC - Reconfigurable SDM Optical Vector Network Analyzer
Optical Fiber Communication Conference, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
reconfigurable spatially diverse optical vector Network Analyzer
Optics Express, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring the partial or complete mode transfer matrix of a system as a function of wavelength in an arbitrary mode basis using single or multiple sweeps.
K. Hoffmann - One of the best experts on this subject based on the ideXlab platform.
-
Seven State PTP for Vector Network Analyzer
2005Co-Authors: Vadim Zavodny, K. Hoffmann, Z. SkvorAbstract:A new, seven-state switched perturbation two- port (PTP) for vector reflection measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octaves. Good agreement with data ob- tained using a precise vector Network Analyzer was achieved. The new calibration method for the PTP was designed and tested on real measured data.
-
7 state PTP for vector Network Analyzer
65th ARFTG Conference Digest 2005. Spring 2005, 2005Co-Authors: Vadim Zavodny, K. Hoffmann, Z. SkvorAbstract:A new, 7 state switched perturbation two-port (PTP) for vector measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octave. Good agreement with data obtained using a precise vector Network Analyzer was achieved.
-
A novel vector Network Analyzer
1998 IEEE MTT-S International Microwave Symposium Digest (Cat. No.98CH36192), 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for perturbation two-port vector Network Analyzer is presented. It consists of a variable perturbation two-port placed between a device under test and a scalar Network Analyzer. A measured vector reflection coefficient is determined on the basis of amplitude only readings. A full correction of systematic errors is possible. The new principle was experimentally confirmed in the frequency band up to 14 GHz.
-
Calibration of the PTP vector Network Analyzer
12th International Conference on Microwaves and Radar. MIKON-98. Conference Proceedings (IEEE Cat. No.98EX195), 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for perturbation two-port vector Network Analyzer (PTP VNA) is presented. PTP VNA consists of a variable perturbation two-port (PTP) placed between a device under test (DUT) and a scalar Network Analyzer (SNA). A vector reflection coefficient of the DUT is determined on the basis of amplitude only measurements. A full correction of SNA systematic errors is possible. In principle it may be used up to millimetre and submillimetre frequency bands.
-
A novel vector Network Analyzer
IEEE Transactions on Microwave Theory and Techniques, 1998Co-Authors: K. Hoffmann, Z. SkvorAbstract:A calibration procedure for a perturbation two-port vector Network Analyzer is presented. It consists of a variable perturbation two-port placed between a device-under-test and a scalar Network Analyzer. A measured vector reflection coefficient is determined on the basis of amplitude-only measurements. A full correction of systematic errors is possible. The new principle was experimentally confirmed in the frequency band up to 14 GHz. The results enable prediction of an add-on for scalar Analyzers, enabling vector measurements.
Benjamin J. Eggleton - One of the best experts on this subject based on the ideXlab platform.
-
Reconfigurable SDM optical vector Network Analyzer
OFC 2014, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
OFC - Reconfigurable SDM Optical Vector Network Analyzer
Optical Fiber Communication Conference, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring some or all of the mode transfer matrix of a system in an arbitrary mode basis using single or multiple sweeps.
-
reconfigurable spatially diverse optical vector Network Analyzer
Optics Express, 2014Co-Authors: Joel Carpenter, Benjamin J. Eggleton, Jochen SchröderAbstract:We present a spatially-diverse optical vector Network Analyzer which is capable of measuring the partial or complete mode transfer matrix of a system as a function of wavelength in an arbitrary mode basis using single or multiple sweeps.