The Experts below are selected from a list of 3753 Experts worldwide ranked by ideXlab platform
Myung Jae Jeon - One of the best experts on this subject based on the ideXlab platform.
-
Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension polyester vs polypropylene
Journal of Minimally Invasive Gynecology, 2020Co-Authors: Jeesun Lee, Myung Jae JeonAbstract:Abstract Study Objective To evaluate Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (PET) and monofilament polypropylene (PP) Sutures were compared. Design A retrospective cohort study. Setting A single teaching hospital. Patients Two hundred and twenty-nine patients who underwent transvaginal USLS and completed a 1-year follow-up. Interventions The use of PET and PP Sutures for transvaginal USLS procedures. Measurements and Main Results PP Sutures were used in 149 patients, and PET Sutures were used in 80 patients. The Suture-related complication rates, including granulation tissue and Suture erosion at the vaginal apex, were significantly higher in the PET Suture group than in the PP Suture group (46.3% vs 20.1%, p Conclusions Compared to the use of multifilament PET Sutures, the use of monofilament PP Sutures in transvaginal USLS may reduce Suture-related complications without increasing surgical failure rates.
-
Suture Complication Rates and Surgical Outcomes According to the Nonabsorbable Suture Materials Used in Vaginal Uterosacral Ligament Suspension: Polyester vs Polypropylene.
Journal of minimally invasive gynecology, 2020Co-Authors: Jeesun Lee, Myung Jae JeonAbstract:To evaluate Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (PET) and monofilament polypropylene (PP) Sutures were compared. A retrospective cohort study. A single teaching hospital. Two hundred and twenty-nine patients who underwent transvaginal USLS and completed a 1-year follow-up. The use of PET and PP Sutures for transvaginal USLS procedures. PP Sutures were used in 149 patients, and PET Sutures were used in 80 patients. The Suture-related complication rates, including granulation tissue and Suture erosion at the vaginal apex, were significantly higher in the PET Suture group than in the PP Suture group (46.3% vs 20.1%, p < .01). However, there was no significant difference in the rates of surgical failure (defined as the presence of vaginal bulging symptoms, apical descent ≥ 1/2 of the total vaginal length, anterior or posterior vaginal wall descent beyond the hymen, or retreatment for prolapse) between the two groups (p = .84). Compared to the use of multifilament PET Sutures, the use of monofilament PP Sutures in transvaginal USLS may reduce Suture-related complications without increasing surgical failure rates. Copyright © 2020. Published by Elsevier Inc.
Yu-ting Kuo - One of the best experts on this subject based on the ideXlab platform.
-
Choledocholithiasis induced by Nonabsorbable Suture material mimicking a pedunculated round tumor in the common hepatic duct: MRCP findings
European Journal of Radiology Extra, 2007Co-Authors: Ming-lun Chiu, Tsyh-jyi Hsieh, Chiao-yun Chen, Twei-shun Jaw, Gin-chung Liu, King-teh Lee, Yu-ting KuoAbstract:Abstract There have been limited reports about the choledocholithiasis formed around Nonabsorbable Suture material in patients who underwent biliary surgery. We report an unusual case of choledocholithiasis in the common hepatic duct formed around the nidus of Suture material, which mimics a pedunculated round tumor on MR cholangiopancreatography (MRCP) images. The diagnosis has been confirmed by surgery.
Jeesun Lee - One of the best experts on this subject based on the ideXlab platform.
-
Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension polyester vs polypropylene
Journal of Minimally Invasive Gynecology, 2020Co-Authors: Jeesun Lee, Myung Jae JeonAbstract:Abstract Study Objective To evaluate Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (PET) and monofilament polypropylene (PP) Sutures were compared. Design A retrospective cohort study. Setting A single teaching hospital. Patients Two hundred and twenty-nine patients who underwent transvaginal USLS and completed a 1-year follow-up. Interventions The use of PET and PP Sutures for transvaginal USLS procedures. Measurements and Main Results PP Sutures were used in 149 patients, and PET Sutures were used in 80 patients. The Suture-related complication rates, including granulation tissue and Suture erosion at the vaginal apex, were significantly higher in the PET Suture group than in the PP Suture group (46.3% vs 20.1%, p Conclusions Compared to the use of multifilament PET Sutures, the use of monofilament PP Sutures in transvaginal USLS may reduce Suture-related complications without increasing surgical failure rates.
-
Suture Complication Rates and Surgical Outcomes According to the Nonabsorbable Suture Materials Used in Vaginal Uterosacral Ligament Suspension: Polyester vs Polypropylene.
Journal of minimally invasive gynecology, 2020Co-Authors: Jeesun Lee, Myung Jae JeonAbstract:To evaluate Suture complication rates and surgical outcomes according to the Nonabsorbable Suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (PET) and monofilament polypropylene (PP) Sutures were compared. A retrospective cohort study. A single teaching hospital. Two hundred and twenty-nine patients who underwent transvaginal USLS and completed a 1-year follow-up. The use of PET and PP Sutures for transvaginal USLS procedures. PP Sutures were used in 149 patients, and PET Sutures were used in 80 patients. The Suture-related complication rates, including granulation tissue and Suture erosion at the vaginal apex, were significantly higher in the PET Suture group than in the PP Suture group (46.3% vs 20.1%, p < .01). However, there was no significant difference in the rates of surgical failure (defined as the presence of vaginal bulging symptoms, apical descent ≥ 1/2 of the total vaginal length, anterior or posterior vaginal wall descent beyond the hymen, or retreatment for prolapse) between the two groups (p = .84). Compared to the use of multifilament PET Sutures, the use of monofilament PP Sutures in transvaginal USLS may reduce Suture-related complications without increasing surgical failure rates. Copyright © 2020. Published by Elsevier Inc.
Edwin C. Mcgough - One of the best experts on this subject based on the ideXlab platform.
-
absorbable polydioxanone Suture and results in total anomalous pulmonary venous connection
The Annals of Thoracic Surgery, 1995Co-Authors: John A. Hawkins, Herbert D Ruttenberg, Judith E. Sturtevant, Luann L Minich, Lloyd Y Tani, Edwin C. McgoughAbstract:Background. Despite theoretical advantages of absorbable Suture in the growing vascular anastomosis, there has not been a documented advantage over Nonabsorbable Suture in preventing late anastomotic stenosis in total anomalous pulmonary venous connection (TAPVC). Methods. We reviewed our experience from 1982 to 1994 with 65 hospital survivors of total TAPVC repair to examine the influence of Suture type on survival and incidence of late pulmonary venous obstruction. From 1982 until 1988, we used continuous Nonabsorbable polypropylene Suture for the pulmonary venous-left atrial anastomosis in supracardiac, infracardiac, and mixed types of TAPVC. In 1989, we adopted a running absorbable polydioxanone Suture technique. Cardiac catheterization and echocardiography were used to evaluate late pulmonary venous obstruction. Results. Late pulmonary venous obstruction occurred in 17% (4/23) of survivors after repair with polypropylene Suture compared with 3.2% (1/32) after repair with polydioxanone Suture ( p Conclusions. Continuous absorbable polydioxanone Suture for the repair of TAPVC results in a low incidence of late pulmonary venous obstruction and death and appears to offer advantages over a continuous Nonabsorbable Suture. A continuous Nonabsorbable Suture may limit growth of a vascular anastomosis, particularly one involving a "low-pressure" anastomosis such as in the repair of TAPVC.
Carol Vaughan - One of the best experts on this subject based on the ideXlab platform.
-
a comparison of absorbable and Nonabsorbable Suture materials for skin repair
Plastic and Reconstructive Surgery, 1992Co-Authors: Bahman Guyuron, Carol VaughanAbstract:This prospective clinical study was conducted to compare the outcome of elective surgical wound repair in the occipital region during rhytidectomy using absorbable and Nonabsorbable Suture materials. On an alternative basis, 6–0 polypropylene and 6–0 plain catgut were used to repair the incisions on