The Experts below are selected from a list of 273 Experts worldwide ranked by ideXlab platform
Kenkichi Ohba - One of the best experts on this subject based on the ideXlab platform.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.
International Journal of Urology, 2020Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:Background : The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. Methods : We carried out a basal experiment measuring flow velocity in model urethras of 4.5–8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Results : Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 ± 4.3 mL/s (mean ± SD; range, 18.4–1.3 mL/s), urethral diameter was 7.3 ± 3.0 mm (mean ± SD; range, 18.7–4.3 mm) and urinary velocity was 69.4 ± 43.6 (mean ± SD; range, 181.3–0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. Conclusion : The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system
International Journal of Urology, 2003Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:BACKGROUND: The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. METHODS: We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. RESULTS: Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. CONCLUSION: The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
Yukio Tsujimoto - One of the best experts on this subject based on the ideXlab platform.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.
International Journal of Urology, 2020Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:Background : The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. Methods : We carried out a basal experiment measuring flow velocity in model urethras of 4.5–8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Results : Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 ± 4.3 mL/s (mean ± SD; range, 18.4–1.3 mL/s), urethral diameter was 7.3 ± 3.0 mm (mean ± SD; range, 18.7–4.3 mm) and urinary velocity was 69.4 ± 43.6 (mean ± SD; range, 181.3–0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. Conclusion : The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system
International Journal of Urology, 2003Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:BACKGROUND: The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. METHODS: We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. RESULTS: Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. CONCLUSION: The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
Yoshiaki Nose - One of the best experts on this subject based on the ideXlab platform.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.
International Journal of Urology, 2020Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:Background : The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. Methods : We carried out a basal experiment measuring flow velocity in model urethras of 4.5–8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Results : Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 ± 4.3 mL/s (mean ± SD; range, 18.4–1.3 mL/s), urethral diameter was 7.3 ± 3.0 mm (mean ± SD; range, 18.7–4.3 mm) and urinary velocity was 69.4 ± 43.6 (mean ± SD; range, 181.3–0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. Conclusion : The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
-
Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system
International Journal of Urology, 2003Co-Authors: Yukio Tsujimoto, Yoshiaki Nose, Kenkichi OhbaAbstract:BACKGROUND: The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. METHODS: We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. RESULTS: Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. CONCLUSION: The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
K.j. Bosschaart - One of the best experts on this subject based on the ideXlab platform.
-
experimental study on a simple ranque hilsch vortex tube
Cryogenics, 2005Co-Authors: K.j. Bosschaart, J. C. H. Zeegers, De Atam Fons WaeleAbstract:Abstract The Ranque–Hilsch vortex tube is a device by which cold gas can be generated using compressed gas. To understand the cooling mechanism of this device, it is necessary to know the pressure, temperature, and velocity distributions inside the tube. In order to investigate this, a simple vortex tube is built and nitrogen is used as its working fluid. A special Pitot tube is used for the measurement of the pressure and velocity. This Pitot tube consists of a capillary which has only one hole in the cylinder wall. With this Pitot tube, the pressure and velocity fields inside the tube were measured. In the same way, the temperature field was measured with a thermocouple. The results of three different entrance conditions are compared here. With the measurements results, the analysis based on the two thermodynamic laws has been made. It is found that rounding off the entrance has influence on the performance of the vortex tube. The secondary circulation gas flow inside the vortex tube can be enhanced and enlarged, the performance of the Ranque–Hilsch vortex tube improved.
-
Experimental study on a simple Ranque–Hilsch vortex tube
Cryogenics, 2005Co-Authors: C M Gao, K.j. Bosschaart, J. C. H. Zeegers, A.th.a.m. De WaeleAbstract:The Ranque–Hilsch vortex tube is a device by which cold gas can be generated using compressed gas. To understand the cooling mechanism of this device, it is necessary to know the pressure, temperature, and velocity distributions inside the tube. In order to investigate this, a simple vortex tube is built and nitrogen is used as its working fluid. A special Pitot tube is used for the measurement of the pressure and velocity. This Pitot tube consists of a capillary which has only one hole in the cylinder wall. With this Pitot tube, the pressure and velocity fields inside the tube were measured. In the same way, the temperature field was measured with a thermocouple. The results of three different entrance conditions are compared here. With the measurements results, the analysis based on the two thermodynamic laws has been made. It is found that rounding off the entrance has influence on the performance of the vortex tube. The secondary circulation gas flow inside the vortex tube can be enhanced and enlarged, the performance of the Ranque–Hilsch vortex tube improved.
A.th.a.m. De Waele - One of the best experts on this subject based on the ideXlab platform.
-
Experimental study on a simple Ranque–Hilsch vortex tube
Cryogenics, 2005Co-Authors: C M Gao, K.j. Bosschaart, J. C. H. Zeegers, A.th.a.m. De WaeleAbstract:The Ranque–Hilsch vortex tube is a device by which cold gas can be generated using compressed gas. To understand the cooling mechanism of this device, it is necessary to know the pressure, temperature, and velocity distributions inside the tube. In order to investigate this, a simple vortex tube is built and nitrogen is used as its working fluid. A special Pitot tube is used for the measurement of the pressure and velocity. This Pitot tube consists of a capillary which has only one hole in the cylinder wall. With this Pitot tube, the pressure and velocity fields inside the tube were measured. In the same way, the temperature field was measured with a thermocouple. The results of three different entrance conditions are compared here. With the measurements results, the analysis based on the two thermodynamic laws has been made. It is found that rounding off the entrance has influence on the performance of the vortex tube. The secondary circulation gas flow inside the vortex tube can be enhanced and enlarged, the performance of the Ranque–Hilsch vortex tube improved.