Julia Woithe - One of the best experts on this subject based on the ideXlab platform.

  • energy dependence of ebt 1 radiochromic film response for photon 10 kvp 15 mvp and electron beams 6 18 mev readout by a flatbed scanner
    Medical Physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

  • Energy dependence of EBT‐1 radiochromic film response for photon and electron beams readout by a flatbed scanner
    Medical physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

Christian Richter - One of the best experts on this subject based on the ideXlab platform.

  • energy dependence of ebt 1 radiochromic film response for photon 10 kvp 15 mvp and electron beams 6 18 mev readout by a flatbed scanner
    Medical Physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

  • Energy dependence of EBT‐1 radiochromic film response for photon and electron beams readout by a flatbed scanner
    Medical physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

J Pawelke - One of the best experts on this subject based on the ideXlab platform.

  • energy dependence of ebt 1 radiochromic film response for photon 10 kvp 15 mvp and electron beams 6 18 mev readout by a flatbed scanner
    Medical Physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

  • Energy dependence of EBT‐1 radiochromic film response for photon and electron beams readout by a flatbed scanner
    Medical physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

L Karsch - One of the best experts on this subject based on the ideXlab platform.

  • energy dependence of ebt 1 radiochromic film response for photon 10 kvp 15 mvp and electron beams 6 18 mev readout by a flatbed scanner
    Medical Physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

  • Energy dependence of EBT‐1 radiochromic film response for photon and electron beams readout by a flatbed scanner
    Medical physics, 2009
    Co-Authors: Christian Richter, L Karsch, J Pawelke, Julia Woithe
    Abstract:

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependencemore » for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

V. Y. Shaposhnyk - One of the best experts on this subject based on the ideXlab platform.

  • theoretical dependence of wear value of friction pair cenetr plate center pad on a freight car mileage
    Science and Transport Progress. Bulletin of Dnipropetrovsk National University of Railway Transport, 2017
    Co-Authors: L. A. Muradian, D. O. Podosenov, V. Y. Shaposhnyk
    Abstract:

    Purpose. The paper considers the interaction of the cylindrical surfaces of the friction pair «center plate – center pad» of the freight car and theoretically investigates the wear process. It is also necessary to obtain the wear value dependence of center pad on the mileage, taking into account the power load, the physical-mechanical and tribo-technical properties of the interacting materials for the subsequent modeling and control of the value of overhaul mileage by the wear criterion of the corresponding resource-determining elements of freight cars. Methodology. For theoretical studies of the wear value of friction pair «center plate – center pad» on the freight car mileage, the theory of friction and wear of solids was used. Findings. In this paper interaction of cylindrical surfaces of the friction pair «center plate – center pad» of a freight car in the form of a «shaft-sleeve» model is considered. Dependences of the permanent and variable wear of a given friction pair are proposed for cases in which forces act in the transverse and longitudinal directions. Obtained dependence of the wear value of center pad on the freight car mileage takes into account the power load, physical and mechanical and tribo-technical properties of the conjugated materials. On its basis, using new materials for repair with various properties, one may simulate the wear state of cylindrical surfaces of the friction pair «center plate – center pad», which will make it possible to control the value of overhaul mileage of freight car. Also (on the example of gondola 12-7023) on the basis of obtained expression there were constructed dependences of the average wear value of center pad for the cases of different values of the mileage use coefficient and the train movement speed. It was shown that with an increase in the train speed to 100 km/h, the average wear value of the gondola 12-7023 center pad is lower by 25% than at the speed of 80 km/h. Originality. In the work on the wear criterion, the interaction of cylindrical surfaces of the friction pair «center plate – center pad» of a freight car is considered. For the first time it was obtained the dependence of wear value of center pad on the mileage taking into account the power load, physical and mechanical and tribo-technical properties of the conjugated materials. Applying new materials for repair with different properties, based on the obtained dependence one can carry out a simulation of the wear state of cylindrical surfaces of friction pair «center plate – center pad», that is to control the value of between-repair mileage of freight car. Practical value. The results of the work make it possible to establish the wear value of canter pad for the corresponding operating mileage of the freight car.

  • THEORETICAL DEPENDENCE OF WEAR VALUE OF FRICTION PAIR «CENETR PLATE – CENTER PAD» ON A FREIGHT CAR MILEAGE
    Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan, 2017
    Co-Authors: L. A. Muradian, D. O. Podosenov, V. Y. Shaposhnyk
    Abstract:

    Purpose. The paper considers the interaction of the cylindrical surfaces of the friction pair «center plate – center pad» of the freight car and theoretically investigates the wear process. It is also necessary to obtain the wear value dependence of center pad on the mileage, taking into account the power load, the physical-mechanical and tribo-technical properties of the interacting materials for the subsequent modeling and control of the value of overhaul mileage by the wear criterion of the corresponding resource-determining elements of freight cars. Методика. For theoretical studies of the wear value of friction pair «center plate – center pad» on the freight car mileage, the theory of friction and wear of solids was used. Findings. In this paper interaction of cylindrical surfaces of the friction pair «center plate – center pad» of a freight car in the form of a «shaft-sleeve» model is considered. Dependences of the permanent and variable wear of a given friction pair are proposed for cases in which forces act in the transverse and longitudinal directions. Obtained dependence of the wear value of center pad on the freight car mileage takes into account the power load, physical and mechanical and tribo-technical properties of the conjugated materials. On its basis, using new materials for repair with various properties, one may simulate the wear state of cylindrical surfaces of the friction pair «center plate – center pad», which will make it possible to control the value of overhaul mileage of freight car. Also (on the example of gondola 12-7023) on the basis of obtained expression there were constructed dependences of the average wear value of center pad for the cases of different values of the mileage use coefficient and the train movement speed. It was shown that with an increase in the train speed to 100 km/h, the average wear value of the gondola 12-7023 center pad is lower by 25% than at the speed of 80 km/h. Originality. In the work on the wear criterion, the interaction of cylindrical surfaces of the friction pair «center plate – center pad» of a freight car is considered. For the first time it was obtained the dependence of wear value of center pad on the mileage taking into account the power load, physical and mechanical and tribo-technical properties of the conjugated materials. Applying new materials for repair with different properties, based on the obtained dependence one can carry out a simulation of the wear state of cylindrical surfaces of friction pair «center plate – center pad», that is to control the value of between-repair mileage of freight car. Practical value. The results of the work make it possible to establish the wear value of canter pad for the corresponding operating mileage of the freight car