Dev Paul - One of the best experts on this subject based on the ideXlab platform.

  • Light rail transit dc traction power system surge overvoltage protection
    IEEE Transactions on Industry Applications, 2002
    Co-Authors: Dev Paul
    Abstract:

    At present, there are no industry standards or recommended\nguidelines for the Application of DC surge arresters. It appears that\nsuch devices are applied based upon a rule of thumb without the benefit\nof analyzing characteristics, wave shape, and energy content of the\nexpected overvoltage surges against the capabilities of the surge\narrester. AC surge arresters are rerated for DC Application. A\ndifficulty arises due to a lack of clear Published Application\nliterature on DC surge arresters, as well as lack of measured data on DC\npower system transient surges. This leads to the Application of surge\nprotective devices, which may be inappropriate. This paper describes the\nApplication of DC surge arresters to a typical light rail transit\ntraction power system, and it makes a recommendation for the need of a\nstandard on DC surge arresters test requirements and Application\nguidelines

  • light rail transit dc traction power system surge overvoltage protection
    International Conference on Pervasive Services, 2001
    Co-Authors: Dev Paul
    Abstract:

    At present there is no industry standard or recommended guidelines for the Application of DC surge arresters. It appears that such devices are applied based upon the rule of thumb without the benefit of analyzing characteristics, wave shape, and energy content of the expected overvoltage surges against the capabilities of the surge arrester. AC surge arresters are re-rated for de Application. A difficulty arises due to lack of clear Published Application literature on the DC surge arresters, as well as lack of measured data on the DC power system transient surges. This leads to the Application of surge protective devices, which may be inappropriate. This paper describes the Application of DC surge arresters to a typical light rail transit (LRT) traction power system, and makes a recommendation of a need of a standard on DC surge arresters test requirements and Application guidelines.

Pavel Pintr - One of the best experts on this subject based on the ideXlab platform.

Antonín Lukš - One of the best experts on this subject based on the ideXlab platform.

Vlasta Peřinová - One of the best experts on this subject based on the ideXlab platform.