The Experts below are selected from a list of 23340 Experts worldwide ranked by ideXlab platform
William R Wagner - One of the best experts on this subject based on the ideXlab platform.
-
an elastomeric patch electrospun from a blended solution of dermal extracellular matrix and biodegradable polyurethane for rat abdominal wall repair
Tissue Engineering Part C-methods, 2012Co-Authors: Yi Hong, Ryotaro Hashizume, Nicholas J Amoroso, William R Wagner, Stephen F Badylak, Keisuke Takanari, Ellen P Brennanpierce, John M FreundAbstract:A biodegradable elastomeric scaffold was created by electrospinning a mixed solution of poly(ester urethane)urea (PEUU) and porcine dermal extracellular matrix (dECM) digest, with PEUU included to provide elasticity, flexibility, and mechanical support and dECM used to enhance bioactivity and biocompatibility. Micrographs and differential scanning calorimetry demonstrated partial miscibility between PEUU and dECM. With greater dECM content, scaffolds were found to possess lower breaking strains and suture Retention Strength, although initial modulus was greater with higher dECM concentrations. The hybrid scaffolds containing 0% to 50% dECM had tensile Strengths of 5 to 7 MPa, breaking strains of 138% to 611%, initial moduli of 3 to 11 Mpa, and suture Retention Strengths of 35 to 59 MPa. When hydrated, scaffolds were found to contract markedly with 50% dECM content. When used in a rat full-thickness abdominal wall replacement model, no herniation, infection, or tissue adhesion was observed after 4 and 8 we...
-
an elastomeric patch electrospun from a blended solution of dermal extracellular matrix and biodegradable polyurethane for rat abdominal wall repair
Tissue Engineering Part C-methods, 2012Co-Authors: Yi Hong, Ryotaro Hashizume, Nicholas J Amoroso, William R Wagner, Stephen F Badylak, Keisuke Takanari, Ellen P Brennanpierce, John M FreundAbstract:A biodegradable elastomeric scaffold was created by electrospinning a mixed solution of poly(ester urethane)urea (PEUU) and porcine dermal extracellular matrix (dECM) digest, with PEUU included to provide elasticity, flexibility, and mechanical support and dECM used to enhance bioactivity and biocompatibility. Micrographs and differential scanning calorimetry demonstrated partial miscibility between PEUU and dECM. With greater dECM content, scaffolds were found to possess lower breaking strains and suture Retention Strength, although initial modulus was greater with higher dECM concentrations. The hybrid scaffolds containing 0% to 50% dECM had tensile Strengths of 5 to 7 MPa, breaking strains of 138% to 611%, initial moduli of 3 to 11 Mpa, and suture Retention Strengths of 35 to 59 MPa. When hydrated, scaffolds were found to contract markedly with 50% dECM content. When used in a rat full-thickness abdominal wall replacement model, no herniation, infection, or tissue adhesion was observed after 4 and 8 weeks with a scaffold containing 25% dECM or a control 100% PEUU scaffold. Scaffolds incorporating dECM were significantly thicker at the time of explant, with greater numbers of associated smooth muscle actin-positive staining cells than in the control, but minimal cellular infiltration and remodeling of the scaffold were detected regardless of dECM addition. The processing of dECM and PEUU from a mixed solution thus provided a scaffold with evidence of better bioactivity and with mechanical properties not achievable with digested dECM alone.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:Abstract There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77±20% vs. 66±6% at day 0) while CD34 expression was reduced (19±12% vs. 61±10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127±900 mmHg and suture Retention Strength was 1.3±0.3 N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77+/-20% vs. 66+/-6% at day 0) while CD34 expression was reduced (19+/-12% vs. 61+/-10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127+/-900 mm Hg and suture Retention Strength was 1.3+/-0.3N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.
David A Vorp - One of the best experts on this subject based on the ideXlab platform.
-
bioresorbable silk grafts for small diameter vascular tissue engineering applications in vitro and in vivo functional analysis
Acta Biomaterialia, 2020Co-Authors: Prerak Gupta, David A Vorp, Katherine L Lorentz, Darren G Haskett, Eoghan M Cunnane, Aneesh K Ramaswamy, Justin S Weinbaum, Biman B MandalAbstract:Abstract The success of tissue-engineered vascular graft (TEVG) predominantly relies on the selection of a suitable biomaterial and graft design. Natural biopolymer silk has shown great promise for various tissue-engineering applications. This study is the first to investigate Indian endemic non-mulberry silk (Antheraea assama-AA) – which inherits naturally superior mechanical and biological traits (e.g., RGD motifs) compared to Bombyx mori-BM silk, for TEVG applications. We designed bi-layered biomimetic small diameter AA-BM silk TEVGs adopting a new fabrication methodology. The inner layer showed ideally sized (~40 µm) pores with interconnectivity to allow cellular infiltration, and an outer dense electrospun layer that confers mechanical resilience. Biodegradation of silk TEVGs into amino acids as resorbable byproducts corroborates their in vivo remodeling ability. Following our previous reports, we surgically implanted human adipose tissue-derived stromal vascular fraction (SVF) seeded silk TEVGs in Lewis rats as abdominal aortic interposition grafts for 8 weeks. Adequate suture Retention Strength (0.45 ± 0.1 N) without any blood seepage post-implantation substantiate the grafts’ viability. AA silk-based TEVGs showed superior animal survival and graft patency compared to BM silk TEVGs. Histological analysis revealed neo-tissue formation, host cell infiltration and graft remodeling in terms of extracellular matrix turnover. Altogether, this study demonstrates promising aspects of AA silk TEVGs for vascular tissue engineering applications. Statement of significance Clinical ‘off the shelf’ implementation of tissue-engineered vascular grafts (TEVGs) remains a challenge. Achieving optimal blood vessel regeneration requires the use of bioresorbable materials having suitable degradation rates while producing minimal or no toxic byproducts. Host cell recruitment and preventing acute thrombosis are other pre-requisites for successful graft remodeling. In this study, for the first time we explored the use of naturally derived Indian endemic non-mulberry Antheraea assama silk in combination with Bombyx mori silk for TEVG applications by adopting a new biomimetic approach. Our bi-layered silk TEVGs were optimally porous, mechanically resilient and biodegradable. In vivo implantation in rat aorta showed long-term patency and graft remodeling by host cell infiltration and extracellular matrix deposition corroborating their clinical feasibility.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:Abstract There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77±20% vs. 66±6% at day 0) while CD34 expression was reduced (19±12% vs. 61±10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127±900 mmHg and suture Retention Strength was 1.3±0.3 N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77+/-20% vs. 66+/-6% at day 0) while CD34 expression was reduced (19+/-12% vs. 61+/-10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127+/-900 mm Hg and suture Retention Strength was 1.3+/-0.3N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.
-
Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique
'Elsevier BV', 2008Co-Authors: Nieponice A, Soletti L, Guan J, Bm Deasy, Huard J, Wr Wagner, David A VorpAbstract:There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77±20% vs. 66±6% at day 0) while CD34 expression was reduced (19±12% vs. 61±10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127±900 mmHg and suture Retention Strength was 1.3±0.3 N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation. © 2007 Elsevier Ltd. All rights reserved
Xin Jing - One of the best experts on this subject based on the ideXlab platform.
-
manipulating the structure and mechanical properties of thermoplastic polyurethane polycaprolactone hybrid small diameter vascular scaffolds fabricated via electrospinning using an assembled rotating collector
Journal of The Mechanical Behavior of Biomedical Materials, 2018Co-Authors: Haoyang Mi, Emily Yu, Qian Li, Xiaofeng Wang, Xin Jing, Lih-sheng TurngAbstract:Abstract The success of blood vessel transplants with vascular scaffolds (VSs) highly depends on their structure and mechanical properties. The fabrication of small diameter vascular scaffolds (SDVSs) mimicking the properties of native blood vessels has been a challenge. Herein, we propose a facile method to fabricate thermoplastic polyurethane (TPU)/polycaprolactone (PCL) hybrid SDVSs via electrospinning using a modified rotating collector. By varying the ratio between the TPU and the PCL, and changing the electrospinning volume, SDVSs with a wavy configuration and different properties could be obtained. Detailed investigation revealed that certain TPU/PCL hybrid SDVSs closely resembled the mechanical behaviors of blood vessels due to the presence of a wavy region and the combination of flexible TPU and rigid PCL, which mimicked the properties of elastin and collagen in blood vessels. The fabricated TPU/PCL SDVSs achieved lumen diameters of 1–3 mm, wall thicknesses of 100–570 µm, circumferential moduli of 1–6 MPa, ultimate Strengths of 2–8 MPa, over 250% elongation-at-break values, toe regions of 5.3–9.4%, high recoverability, and compliances close to those of human veins. Moreover, these TPU/PCL SDVSs possessed sufficient suture Retention Strength and burst pressure to fulfill transplantation requirements and maintain normal blood flow. Human endothelial cell culture revealed good biocompatibility of the scaffolds, and cells were able to grow on the inner surface of the tubular scaffolds, indicating promising prospects for use as tissue-engineered vascular grafts.
-
electrospinning thermoplastic polyurethane graphene oxide scaffolds for small diameter vascular graft applications
Materials Science and Engineering: C, 2015Co-Authors: Travis Cordie, Max R. Salick, Xiangfang Peng, Haoyang Mi, Xin Jing, Lih-sheng TurngAbstract:Abstract Fabrication of small diameter vascular grafts plays an important role in vascular tissue engineering. In this study, thermoplastic polyurethane (TPU)/graphene oxide (GO) scaffolds were fabricated via electrospinning at different GO contents as potential candidates for small diameter vascular grafts. In terms of mechanical and surface properties, the tensile Strength, Young's modulus, and hydrophilicity of the scaffolds increased with an increase of GO content while plasma treatment dramatically improved the scaffold hydrophilicity. Mouse fibroblast (3T3) and human umbilical vein endothelial cells (HUVECs) were cultured on the scaffolds separately to study their biocompatibility and potential to be used as vascular grafts. It was found that cell viability for both types of cells, fibroblast proliferation, and HUVEC attachment were the highest at a 0.5 wt.% GO loading whereas oxygen plasma treatment also enhanced HUVEC viability and attachment significantly. In addition, the suture Retention Strength and burst pressure of tubular TPU/GO scaffolds containing 0.5 wt.% GO were found to meet the requirements of human blood vessels, and endothelial cells were able to attach to the inner surface of the tubular scaffolds. Platelet adhesion tests using mice blood indicated that vascular scaffolds containing 0.5% GO had low platelet adhesion and activation. Therefore, the electrospun TPU/GO tubular scaffolds have the potential to be used in vascular tissue engineering.
Lih-sheng Turng - One of the best experts on this subject based on the ideXlab platform.
-
manipulating the structure and mechanical properties of thermoplastic polyurethane polycaprolactone hybrid small diameter vascular scaffolds fabricated via electrospinning using an assembled rotating collector
Journal of The Mechanical Behavior of Biomedical Materials, 2018Co-Authors: Haoyang Mi, Emily Yu, Qian Li, Xiaofeng Wang, Xin Jing, Lih-sheng TurngAbstract:Abstract The success of blood vessel transplants with vascular scaffolds (VSs) highly depends on their structure and mechanical properties. The fabrication of small diameter vascular scaffolds (SDVSs) mimicking the properties of native blood vessels has been a challenge. Herein, we propose a facile method to fabricate thermoplastic polyurethane (TPU)/polycaprolactone (PCL) hybrid SDVSs via electrospinning using a modified rotating collector. By varying the ratio between the TPU and the PCL, and changing the electrospinning volume, SDVSs with a wavy configuration and different properties could be obtained. Detailed investigation revealed that certain TPU/PCL hybrid SDVSs closely resembled the mechanical behaviors of blood vessels due to the presence of a wavy region and the combination of flexible TPU and rigid PCL, which mimicked the properties of elastin and collagen in blood vessels. The fabricated TPU/PCL SDVSs achieved lumen diameters of 1–3 mm, wall thicknesses of 100–570 µm, circumferential moduli of 1–6 MPa, ultimate Strengths of 2–8 MPa, over 250% elongation-at-break values, toe regions of 5.3–9.4%, high recoverability, and compliances close to those of human veins. Moreover, these TPU/PCL SDVSs possessed sufficient suture Retention Strength and burst pressure to fulfill transplantation requirements and maintain normal blood flow. Human endothelial cell culture revealed good biocompatibility of the scaffolds, and cells were able to grow on the inner surface of the tubular scaffolds, indicating promising prospects for use as tissue-engineered vascular grafts.
-
electrospinning thermoplastic polyurethane graphene oxide scaffolds for small diameter vascular graft applications
Materials Science and Engineering: C, 2015Co-Authors: Travis Cordie, Max R. Salick, Xiangfang Peng, Haoyang Mi, Xin Jing, Lih-sheng TurngAbstract:Abstract Fabrication of small diameter vascular grafts plays an important role in vascular tissue engineering. In this study, thermoplastic polyurethane (TPU)/graphene oxide (GO) scaffolds were fabricated via electrospinning at different GO contents as potential candidates for small diameter vascular grafts. In terms of mechanical and surface properties, the tensile Strength, Young's modulus, and hydrophilicity of the scaffolds increased with an increase of GO content while plasma treatment dramatically improved the scaffold hydrophilicity. Mouse fibroblast (3T3) and human umbilical vein endothelial cells (HUVECs) were cultured on the scaffolds separately to study their biocompatibility and potential to be used as vascular grafts. It was found that cell viability for both types of cells, fibroblast proliferation, and HUVEC attachment were the highest at a 0.5 wt.% GO loading whereas oxygen plasma treatment also enhanced HUVEC viability and attachment significantly. In addition, the suture Retention Strength and burst pressure of tubular TPU/GO scaffolds containing 0.5 wt.% GO were found to meet the requirements of human blood vessels, and endothelial cells were able to attach to the inner surface of the tubular scaffolds. Platelet adhesion tests using mice blood indicated that vascular scaffolds containing 0.5% GO had low platelet adhesion and activation. Therefore, the electrospun TPU/GO tubular scaffolds have the potential to be used in vascular tissue engineering.
Alejandro Nieponice - One of the best experts on this subject based on the ideXlab platform.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:Abstract There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77±20% vs. 66±6% at day 0) while CD34 expression was reduced (19±12% vs. 61±10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127±900 mmHg and suture Retention Strength was 1.3±0.3 N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.
-
development of a tissue engineered vascular graft combining a biodegradable scaffold muscle derived stem cells and a rotational vacuum seeding technique
Biomaterials, 2008Co-Authors: Alejandro Nieponice, William R Wagner, Lorenzo Soletti, Jianjun Guan, Bridget M Deasy, Johnny Huard, David A VorpAbstract:There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture Retention Strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35 h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77+/-20% vs. 66+/-6% at day 0) while CD34 expression was reduced (19+/-12% vs. 61+/-10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst Strength of the TEVG constructs was 2127+/-900 mm Hg and suture Retention Strength was 1.3+/-0.3N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for up to 7 days of in-vitro culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation.