The Experts below are selected from a list of 87 Experts worldwide ranked by ideXlab platform
Dan G. Halpern - One of the best experts on this subject based on the ideXlab platform.
-
USE OF A BIDIRECTIONAL GLENN SHUNT TO ENABLE CLOSURE OF AN ATRIAL SEPTAL DEFECT IN THE SETTING OF RIGHT VENTRICULAR HYPOPLASIA
Journal of the American College of Cardiology, 2018Co-Authors: Jason Costa, Rachel Smaldone, Michael Argilla, Ralph S. Mosca, Dan G. HalpernAbstract:Management of atrial septal defects (ASD) in patients with abnormal RV anatomy or function is challenging, as simple ASD closure may not be hemodynamically tolerated. A 34-year-old woman presented with progressive dyspnea. Physical exam revealed hypoxia (SpO2 72%), fixed Split S2, and digital
Smonporn Boonyaratavej - One of the best experts on this subject based on the ideXlab platform.
-
Scimitar sign in a patient with an atrial septal defect: a comprehensive noninvasive assessment with transthoracic echocardiography and computed tomography.
Journal of the American College of Cardiology, 2009Co-Authors: Sarinya Puwanant, Monravee Tumkosit, Surapun Sitthisook, Wacin Buddhari, Voravut Rungpradubvong, Smonporn BoonyaratavejAbstract:![Figure][1] [![Graphic][3] ][3][![Graphic][4] ][4] A 30-year-old woman was referred for a percutaneous atrial septal defect (ASD) closure. She was acyanotic. She had a systolic ejection murmur and a wide-fixed Split S2. The chest radiograph showed cardiomegaly; pulmonary
Jason Costa - One of the best experts on this subject based on the ideXlab platform.
-
USE OF A BIDIRECTIONAL GLENN SHUNT TO ENABLE CLOSURE OF AN ATRIAL SEPTAL DEFECT IN THE SETTING OF RIGHT VENTRICULAR HYPOPLASIA
Journal of the American College of Cardiology, 2018Co-Authors: Jason Costa, Rachel Smaldone, Michael Argilla, Ralph S. Mosca, Dan G. HalpernAbstract:Management of atrial septal defects (ASD) in patients with abnormal RV anatomy or function is challenging, as simple ASD closure may not be hemodynamically tolerated. A 34-year-old woman presented with progressive dyspnea. Physical exam revealed hypoxia (SpO2 72%), fixed Split S2, and digital
Sarinya Puwanant - One of the best experts on this subject based on the ideXlab platform.
-
Scimitar sign in a patient with an atrial septal defect: a comprehensive noninvasive assessment with transthoracic echocardiography and computed tomography.
Journal of the American College of Cardiology, 2009Co-Authors: Sarinya Puwanant, Monravee Tumkosit, Surapun Sitthisook, Wacin Buddhari, Voravut Rungpradubvong, Smonporn BoonyaratavejAbstract:![Figure][1] [![Graphic][3] ][3][![Graphic][4] ][4] A 30-year-old woman was referred for a percutaneous atrial septal defect (ASD) closure. She was acyanotic. She had a systolic ejection murmur and a wide-fixed Split S2. The chest radiograph showed cardiomegaly; pulmonary
Mohan R - One of the best experts on this subject based on the ideXlab platform.
-
Effect of sources, Split and foliar application of KCl and KClO3 on uptake of potassium in aerobic rice
Journal of Pharmacognosy and Phytochemistry, 2018Co-Authors: Anji Babu P, Omar Hattab K, Aruna L, Mohan RAbstract:A field experiment was conducted in the sandy loam soil (Fluventic haplustept) of Pandit Jawaharlal Nehru College of Agri- culture and Research Institute, Karaikal, during Kharif 2015 to investigate the effect of KCl and KClO3 as sources of potassium in aerobic rice with four types of Split doses and two levels of foliar applications of potassium. The experiment was laid out in Randomised Block Design with three replications. As such, the treatments consisted of three factors viz., sources, Split and foliar applications. The rice variety PMK 4 was tested with two sources of potassium viz., Potassium chloride (KCl) and Potassium chlorate (KClO3), four types of Split application viz., K control (S1), basal with no Split (S2), two Splits (S3) and three Splits (S4) along with foliar application treatments viz., no foliar (F1) and foliar spray (F2). The results of field experiment revealed that the growth para meters like plant height, leaf area index, number of tillers, productive tillers, dry matter production and root biomass were significantly influenced by sources, Split and foliar application of potassium. Similarly, the yield components viz., panicle length, panicle weight, test weight, number of grains per panicle, number of spikelets per panicle, spikelet fertility, high density grains per panicle were also found to be significantly influenced by the sources, Splits and foliar application of potassium. On the whole, this investigation had revealed that KClO3 could also be used as one of the sources of potassium for the growth and yield of aerobic rice. The application of potassium either through KCl or KClO3 in three equal Splits at basal, panicle initiation and flowering stages along with foliar application could be suggested as a strategy of potassium management for yield maximization in aerobic rice.