Water Monitoring

14,000,000 Leading Edge Experts on the ideXlab platform

Scan Science and Technology

Contact Leading Edge Experts & Companies

Scan Science and Technology

Contact Leading Edge Experts & Companies

The Experts below are selected from a list of 319767 Experts worldwide ranked by ideXlab platform

Nico Boon - One of the best experts on this subject based on the ideXlab platform.

  • flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: S Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon
    Abstract:

    Abstract Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically

  • Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: Sam Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon, Frederik Hammes
    Abstract:

    Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 Water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and Monitoring drinking Water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine Water quality Monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking Water.

C. R. Proctor - One of the best experts on this subject based on the ideXlab platform.

  • flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: S Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon
    Abstract:

    Abstract Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically

  • Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: Sam Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon, Frederik Hammes
    Abstract:

    Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 Water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and Monitoring drinking Water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine Water quality Monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking Water.

Johannes S. Vrouwenvelder - One of the best experts on this subject based on the ideXlab platform.

  • flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: S Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon
    Abstract:

    Abstract Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically

  • Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: Sam Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon, Frederik Hammes
    Abstract:

    Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 Water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and Monitoring drinking Water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine Water quality Monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking Water.

Frederik Hammes - One of the best experts on this subject based on the ideXlab platform.

  • Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: Sam Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon, Frederik Hammes
    Abstract:

    Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 Water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and Monitoring drinking Water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine Water quality Monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking Water.

A. Knezev - One of the best experts on this subject based on the ideXlab platform.

  • flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: S Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon
    Abstract:

    Abstract Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically

  • Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking Water Monitoring
    Water Research, 2017
    Co-Authors: Sam Van Nevel, A. Knezev, C. R. Proctor, M. D. Besmer, Stefan Koetzsch, E.i. Prest, Johannes S. Vrouwenvelder, Nico Boon, Frederik Hammes
    Abstract:

    Drinking Water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological Water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved Water quality Monitoring. After more than a decade of application in drinking Water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 Water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and Monitoring drinking Water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine Water quality Monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking Water.