Pawel Ligeza - One of the best experts on this subject based on the ideXlab platform.

  • constant temperature anemometer bandwidth shape determination for energy spectrum study of turbulent flows
    Energies, 2021
    Co-Authors: Pawel Ligeza
    Abstract:

    Due to their common occurrence and fundamental role in human-realized processes and natural phenomena, turbulent flows are subject to constant research. One of the research tools used in these studies are hot-wire Anemometers. These instruments allow for measurements in turbulent flows in a wide range of both velocities and frequencies of fluctuations. This article describes a new indirect method of determining the bandwidth shape of a constant-temperature anemometer. The knowledge of this bandwidth is an important factor in the study of the energy spectrum of turbulent flows.

  • model and simulation studies of the method for optimization of dynamic properties of tachometric Anemometers
    Sensors, 2018
    Co-Authors: Pawel Ligeza
    Abstract:

    Mechanical tachometric Anemometers, based on the phenomenon of the exchange of momentum between the flow and rotating measuring element, represent an important class of instruments used in flow metrology. In particular, they are used in meteorological and ventilation measurements. Mechanical Anemometers with rotating measuring element are, however, known for their drawback related to their poor dynamic properties resulting from relatively large dimensions and mechanical inertia of the measuring element. In these instruments, the phenomenon of overestimating the measured average velocity caused by the inertia of the rotor takes place. Optimization of the dynamics of the measurement process, as well as the estimation and minimization of the measurement uncertainty, can be performed based on mathematical model of anemometer. In this study, a new, original concept of optimization of dynamic properties of tachometric Anemometers is proposed, and the results of model and simulation studies are presented. The new concept of measuring instrument is based on the use of feedback and active control of the rotor. The new method was tested using model research, where two types of flow velocity excitations were applied: sinusoidal and rectangular. The tests carried out showed that the developed method allows for minimization of the dynamic uncertainty of the measurement and minimizes the phenomenon of average flow velocity overestimation occurring in time-varying flows. It has been shown that the use of optimization system allows for approximately tenfold reduction of the error of average velocity measurement in the case of pulsating flows. In addition, the optimization systems allow for anemometer's transmission bandwidth to be extended about a hundred times. This creates new application possibilities for these instruments and allows for a large reduction of measurement uncertainty.

  • an alternative mathematical model of vane Anemometers based on the balance of power
    Flow Measurement and Instrumentation, 2017
    Co-Authors: Pawel Ligeza
    Abstract:

    Abstract Anemometers based on the exchange of momentum between the flow and rotating measuring element comprise an important class of instruments used in flow metrology, especially in meteorological and ventilation measurements. In these instruments, overvaluation of the measured average velocity, caused by the inertia of their rotors, takes place. To analyse this phenomenon and the dynamics of the measurement process, as well as to estimate and minimize the measurement uncertainty, it is required to be acquainted with the mathematical model of the anemometer. In this study, the model of the vane anemometer based on the equation of motion of its rotor available in the literature is analysed, and a new model based on the power balance is proposed. Model testing and a comparison of both models has also been performed.

  • optimization of single sensor two state hot wire anemometer transmission bandwidth
    Sensors, 2008
    Co-Authors: Pawel Ligeza
    Abstract:

    Hot-wire anemometric measurements of non-isothermal flows require the use of thermal compensation or correction circuitry. One possible solution is a two-state hot-wire anemometer that uses the cyclically changing heating level of a single sensor. The area in which flow velocity and fluid temperature can be measured is limited by the dimensions of the sensor's active element. The system is designed to measure flows characterized by high velocity and temperature gradients, although its transmission bandwidth is very limited. In this study, we propose a method to optimize the two-state hot-wire anemometer transmission bandwidth. The method is based on the use of a specialized constant-temperature system together with variable dynamic parameters. It is also based on a suitable measurement cycle paradigm. Analysis of the method was undertaken using model testing. Our results reveal a possible significant broadening of the two-state hot-wire anemometer's transmission bandwidth.

  • constant bandwidth constant temperature hot wire anemometer
    Review of Scientific Instruments, 2007
    Co-Authors: Pawel Ligeza
    Abstract:

    A constant-temperature anemometer (CTA) enables the measurement of fast-changing velocity fluctuations. In the classical solution of CTA, the transmission band is a function of flow velocity. This is a minor drawback when the mean flow velocity does not significantly change, though it might lead to dynamic errors when flow velocity varies over a considerable range. A modification is outlined, whereby an adaptive controller is incorporated in the CTA system such that the anemometer’s transmission band remains constant in the function of flow velocity. For that purpose, a second feedback loop is provided, and the output signal from the anemometer will regulate the controller’s parameters such that the transmission bandwidth remains constant. The mathematical model of a CTA that has been developed and model testing data allow a through evaluation of the proposed solution. A modified anemometer can be used in measurements of high-frequency variable flows in a wide range of velocities. The proposed modificatio...

Santiago Pindado - One of the best experts on this subject based on the ideXlab platform.

  • on the signature of cup Anemometers opto electronic output signal extraction based on fourier analysis
    Measurement, 2019
    Co-Authors: Alvaro Ramoscenzano, Mikel Oguetagutierrez, Santiago Pindado
    Abstract:

    Abstract The output signal of cup Anemometers equipped with opto-electronic output signal generators (such as Vector Instruments A100 LK or Thies First Class Advanced) is analyzed to extract the signature of the anemometer. This signature is a unique information for each single anemometer whose output signal is a train of square-pulses. This signature reflects errors introduced within the fabrication process of the slotted wheels from the opto-electronic output signal generator. The signature of a cup anemometer can be used to filter the output signal, increasing the accuracy of the wind sensor.

  • the cup anemometer a fundamental meteorological instrument for the wind energy industry research at the idr upm institute
    Sensors, 2014
    Co-Authors: Santiago Pindado, Javier Cubas, Felix Sorribespalmer
    Abstract:

    The results of several research campaigns investigating cup anemometer performance carried out since 2008 at the IDR/UPM Institute are included in the present paper. Several analysis of large series of calibrations were done by studying the effect of the rotor’s geometry, climatic conditions during calibration, and Anemometers’ ageing. More specific testing campaigns were done regarding the cup anemometer rotor aerodynamics, and the anemometer signals. The effect of the rotor’s geometry on the cup anemometer transfer function has been investigated experimentally and analytically. The analysis of the anemometer’s output signal as a way of monitoring the anemometer status is revealed as a promising procedure for detecting anomalies.

  • mathematical analysis of the effect of rotor geometry on cup anemometer response
    The Scientific World Journal, 2014
    Co-Authors: Angel Sanzandres, Santiago Pindado, Felix Sorribespalmer
    Abstract:

    The calibration coefficients of two commercial Anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance.

  • aerodynamic analysis of cup Anemometers performance the stationary harmonic response
    The Scientific World Journal, 2013
    Co-Authors: Santiago Pindado, Javier Cubas, Angel Sanzandres
    Abstract:

    The effect of cup anemometer shape parameters, such as the cups' shape, their size, and their center rotation radius, was experimentally analyzed. This analysis was based on both the calibration constants of the transfer function and the most important harmonic term of the rotor's movement, which due to the cup anemometer design is the third one. This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer's rotor and the mentioned third harmonic term of its movement.

  • cup Anemometers loss of performance due to ageing processes and its effect on annual energy production aep estimates
    Energies, 2012
    Co-Authors: Santiago Pindado, A Barrerogil, Alfredo Sanz
    Abstract:

    The deviation of calibration coefficients from five cup anemometer models over time was analyzed. The analysis was based on a series of laboratory calibrations between January 2001 and August 2010. The analysis was performed on two different groups of Anemometers: (1) Anemometers not used for any industrial purpose (that is, just stored); and (2) Anemometers used in different industrial applications (mainly in the field—or outside—applications like wind farms). Results indicate a loss of performance of the studied Anemometers over time. In the case of the unused Anemometers the degradation shows a clear pattern. In the case of the Anemometers used in the field, the data analyzed also suggest a loss of performance, yet the degradation does not show a clear trend. A recalibration schedule is proposed based on the observed performances variations.

Brent E Ewers - One of the best experts on this subject based on the ideXlab platform.

  • A Bayesian model to correct underestimated 3-D wind speeds from sonic Anemometers increases turbulent components of the surface energy balance
    Atmospheric Measurement Techniques, 2016
    Co-Authors: John M Frank, William J Massman, Brent E Ewers
    Abstract:

    Abstract. Sonic Anemometers are the principal instruments in micrometeorological studies of turbulence and ecosystem fluxes. Common designs underestimate vertical wind measurements because they lack a correction for transducer shadowing, with no consensus on a suitable correction. We reanalyze a subset of data collected during field experiments in 2011 and 2013 featuring two or four CSAT3 sonic Anemometers. We introduce a Bayesian analysis to resolve the three-dimensional correction by optimizing differences between Anemometers mounted both vertically and horizontally. A grid of 512 points (∼ ±5° resolution in wind location) is defined on a sphere around the sonic anemometer, from which the shadow correction for each transducer pair is derived from a set of 138 unique state variables describing the quadrants and borders. Using the Markov chain Monte Carlo (MCMC) method, the Bayesian model proposes new values for each state variable, recalculates the fast-response data set, summarizes the 5 min wind statistics, and accepts the proposed new values based on the probability that they make measurements from vertical and horizontal Anemometers more equivalent. MCMC chains were constructed for three different prior distributions describing the state variables: no shadow correction, the Kaimal correction for transducer shadowing, and double the Kaimal correction, all initialized with 10 % uncertainty. The final posterior correction did not depend on the prior distribution and revealed both self- and cross-shadowing effects from all transducers. After correction, the vertical wind velocity and sensible heat flux increased  ∼ 10 % with  ∼ 2 % uncertainty, which was significantly higher than the Kaimal correction. We applied the posterior correction to eddy-covariance data from various sites across North America and found that the turbulent components of the energy balance (sensible plus latent heat flux) increased on average between 8 and 12 %, with an average 95 % credible interval between 6 and 14 %. Considering this is the most common sonic anemometer in the AmeriFlux network and is found widely within FLUXNET, these results provide a mechanistic explanation for much of the energy imbalance at these sites where all terrestrial/atmospheric fluxes of mass and energy are likely underestimated.

  • all sonic Anemometers need to correct for transducer and structural shadowing in their velocity measurements
    Journal of Atmospheric and Oceanic Technology, 2016
    Co-Authors: J M Frank, William J Massman, Edward Swiatek, Herb A Zimmerman, Brent E Ewers
    Abstract:

    AbstractSonic anemometry is fundamental to all eddy-covariance studies of surface energy and ecosystem carbon and water balance. Recent studies have shown that some nonorthogonal Anemometers underestimate vertical wind. Here it is hypothesized that this is due to a lack of transducer and structural shadowing correction. This is tested with a replicated intercomparison experiment between orthogonal (K-probe, Applied Technologies, Inc.) and nonorthogonal (A-probe, Applied Technologies, Inc.; and CSAT3 and CSAT3V, Campbell Scientific, Inc.) anemometer designs. For each of the 12 weeks, five randomly selected and located Anemometers were mounted both vertically and horizontally. Bayesian analysis was used to test differences between half-hourly anemometer measurements of the standard deviation of wind (σu, συ, and σw) and temperature, turbulent kinetic energy (TKE), the ratio between vertical/horizontal TKE (VHTKE), and sensible heat flux (H). Datasets were analyzed with various applications of transducer sha...

  • underestimates of sensible heat flux due to vertical velocity measurement errors in non orthogonal sonic Anemometers
    Agricultural and Forest Meteorology, 2013
    Co-Authors: William J Massman, J M Frank, Brent E Ewers
    Abstract:

    a b s t r a c t Sonic thermometry and anemometry are fundamental to all eddy-covariance studies of surface energy balance. Recent studies have suggested that sonic Anemometers with non-orthogonal transducers can underestimate vertical wind velocity (w) and sensible heat flux (H) when compared to orthogonal designs. In this study we tested whether a non-orthogonal sonic anemometer (CSAT3, Campbell Scientific, Inc.) measures lower w and H than an orthogonal sonic anemometer (SATI/3Vx, Applied Technologies, Inc.) and through experimental manipulation we tested if this difference can be attributed to errors in the CSAT3. Four CSAT3s and one SATI/3Vx were mounted symmetrically in a horizontal array on top of the Glacier Lakes Ecosystem Experiments Site (GLEES) AmeriFlux scaffold (southeastern Wyoming, USA) and in close enough proximity to allow covariance measurements between neighboring sonic Anemometers. The CSAT3s were paired and measurements of the three orthogonal wind velocities (u, v, and w) were tested by alternatively rotating each sonic anemometer 90◦ around its u-axis, essentially forcing the sonic v-axis transducer system to measure w. Analysis was performed on data corresponding to gusts of wind located within the 15◦ cone defined around the u-axis to ensure operation within manufacturer specifications. We found that the CSAT3 measured 8% lower H than the SATI/3Vx and that was associated with a 6-12% lower measurement of w. From the CSAT3 manipulations we found w was underestimated by 6-10% which led directly to an 8-12% underestimate of the kinematic heat flux, the fundamental covariance of H. These results have implications for ecosystem flux research and the energy imbalance problem considering the prevalence of the CSAT3 and the non-orthogonal sonic anemometer design. Published by Elsevier B.V.

William J Massman - One of the best experts on this subject based on the ideXlab platform.

  • coordinate rotation amplification in the uncertainty and bias in non orthogonal sonic anemometer vertical wind speeds
    Boundary-Layer Meteorology, 2020
    Co-Authors: John M Frank, William J Massman, Stephen W Chan, Keith Nowicki, Scot C R Rafkin
    Abstract:

    Recent research indicates that non-orthogonal sonic Anemometers underestimate vertical wind velocity and consequently eddy-covariance fluxes of mass and energy. Whether this is a general problem among all non-orthogonal sonic Anemometers, including those calibrated for flow-shadowing effects, is unknown. To investigate this, we test two sonic anemometer designs, orthogonal (3Vx-probe, Applied Technologies, Inc.) and non-orthogonal (R3-50, Gill Instruments, Ltd.), in a series of field manipulation experiments featuring replicate instruments mounted in various orientations, and use a Bayesian analysis to determine the most likely posterior correction to produce equivalent measurements. The 3Vx-probe experiment was conducted on a 24-m scaffold at the Glacier Lakes Ecosystem Experiments Site (GLEES), Wyoming, USA AmeriFlux site while R3-50 anemometer experiments were conducted at the GLEES field site and on a 2.9-m scaffold at the Pawnee National Grassland, Colorado, USA. Without applying a shadowing correction to the 3Vx-probe, the posterior correction significantly increases the standard deviation of the horizontal velocity component by 5–15% (95% Bayesian credible interval) but without a significant change in the horizontal temperature flux; with the shadowing correction applied neither of these have significant changes. Similarly, for the R3-50 GLEES experiment, the standard deviation of the vertical velocity and vertical temperature flux significantly increase by 13–18% and 6–10% (95% credible intervals); results from the Pawnee experiment are contradictory and inconclusive. The reason for the underestimated vertical velocity is undetermined, though a mathematical by-product of the non-orthogonal geometry is that small systematic measurement biases can become large uncertainties in the vertical velocity. This could affect all non-orthogonal designs.

  • A Bayesian model to correct underestimated 3-D wind speeds from sonic Anemometers increases turbulent components of the surface energy balance
    Atmospheric Measurement Techniques, 2016
    Co-Authors: John M Frank, William J Massman, Brent E Ewers
    Abstract:

    Abstract. Sonic Anemometers are the principal instruments in micrometeorological studies of turbulence and ecosystem fluxes. Common designs underestimate vertical wind measurements because they lack a correction for transducer shadowing, with no consensus on a suitable correction. We reanalyze a subset of data collected during field experiments in 2011 and 2013 featuring two or four CSAT3 sonic Anemometers. We introduce a Bayesian analysis to resolve the three-dimensional correction by optimizing differences between Anemometers mounted both vertically and horizontally. A grid of 512 points (∼ ±5° resolution in wind location) is defined on a sphere around the sonic anemometer, from which the shadow correction for each transducer pair is derived from a set of 138 unique state variables describing the quadrants and borders. Using the Markov chain Monte Carlo (MCMC) method, the Bayesian model proposes new values for each state variable, recalculates the fast-response data set, summarizes the 5 min wind statistics, and accepts the proposed new values based on the probability that they make measurements from vertical and horizontal Anemometers more equivalent. MCMC chains were constructed for three different prior distributions describing the state variables: no shadow correction, the Kaimal correction for transducer shadowing, and double the Kaimal correction, all initialized with 10 % uncertainty. The final posterior correction did not depend on the prior distribution and revealed both self- and cross-shadowing effects from all transducers. After correction, the vertical wind velocity and sensible heat flux increased  ∼ 10 % with  ∼ 2 % uncertainty, which was significantly higher than the Kaimal correction. We applied the posterior correction to eddy-covariance data from various sites across North America and found that the turbulent components of the energy balance (sensible plus latent heat flux) increased on average between 8 and 12 %, with an average 95 % credible interval between 6 and 14 %. Considering this is the most common sonic anemometer in the AmeriFlux network and is found widely within FLUXNET, these results provide a mechanistic explanation for much of the energy imbalance at these sites where all terrestrial/atmospheric fluxes of mass and energy are likely underestimated.

  • all sonic Anemometers need to correct for transducer and structural shadowing in their velocity measurements
    Journal of Atmospheric and Oceanic Technology, 2016
    Co-Authors: J M Frank, William J Massman, Edward Swiatek, Herb A Zimmerman, Brent E Ewers
    Abstract:

    AbstractSonic anemometry is fundamental to all eddy-covariance studies of surface energy and ecosystem carbon and water balance. Recent studies have shown that some nonorthogonal Anemometers underestimate vertical wind. Here it is hypothesized that this is due to a lack of transducer and structural shadowing correction. This is tested with a replicated intercomparison experiment between orthogonal (K-probe, Applied Technologies, Inc.) and nonorthogonal (A-probe, Applied Technologies, Inc.; and CSAT3 and CSAT3V, Campbell Scientific, Inc.) anemometer designs. For each of the 12 weeks, five randomly selected and located Anemometers were mounted both vertically and horizontally. Bayesian analysis was used to test differences between half-hourly anemometer measurements of the standard deviation of wind (σu, συ, and σw) and temperature, turbulent kinetic energy (TKE), the ratio between vertical/horizontal TKE (VHTKE), and sensible heat flux (H). Datasets were analyzed with various applications of transducer sha...

  • underestimates of sensible heat flux due to vertical velocity measurement errors in non orthogonal sonic Anemometers
    Agricultural and Forest Meteorology, 2013
    Co-Authors: William J Massman, J M Frank, Brent E Ewers
    Abstract:

    a b s t r a c t Sonic thermometry and anemometry are fundamental to all eddy-covariance studies of surface energy balance. Recent studies have suggested that sonic Anemometers with non-orthogonal transducers can underestimate vertical wind velocity (w) and sensible heat flux (H) when compared to orthogonal designs. In this study we tested whether a non-orthogonal sonic anemometer (CSAT3, Campbell Scientific, Inc.) measures lower w and H than an orthogonal sonic anemometer (SATI/3Vx, Applied Technologies, Inc.) and through experimental manipulation we tested if this difference can be attributed to errors in the CSAT3. Four CSAT3s and one SATI/3Vx were mounted symmetrically in a horizontal array on top of the Glacier Lakes Ecosystem Experiments Site (GLEES) AmeriFlux scaffold (southeastern Wyoming, USA) and in close enough proximity to allow covariance measurements between neighboring sonic Anemometers. The CSAT3s were paired and measurements of the three orthogonal wind velocities (u, v, and w) were tested by alternatively rotating each sonic anemometer 90◦ around its u-axis, essentially forcing the sonic v-axis transducer system to measure w. Analysis was performed on data corresponding to gusts of wind located within the 15◦ cone defined around the u-axis to ensure operation within manufacturer specifications. We found that the CSAT3 measured 8% lower H than the SATI/3Vx and that was associated with a 6-12% lower measurement of w. From the CSAT3 manipulations we found w was underestimated by 6-10% which led directly to an 8-12% underestimate of the kinematic heat flux, the fundamental covariance of H. These results have implications for ecosystem flux research and the energy imbalance problem considering the prevalence of the CSAT3 and the non-orthogonal sonic anemometer design. Published by Elsevier B.V.