The Experts below are selected from a list of 315 Experts worldwide ranked by ideXlab platform

Eulogio Jiménez - One of the best experts on this subject based on the ideXlab platform.

  • THE TERNARY SYSTEM PROPYL PROPANOATE+ HEXANE+Chlorobenzene AT 298.15 K Excess molar enthalpies
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

  • The ternary system propyl propanoate+ hexane+Chlorobenzene at 298.15 k
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

Sonia Freire - One of the best experts on this subject based on the ideXlab platform.

  • THE TERNARY SYSTEM PROPYL PROPANOATE+ HEXANE+Chlorobenzene AT 298.15 K Excess molar enthalpies
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

  • The ternary system propyl propanoate+ hexane+Chlorobenzene at 298.15 k
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

Kevin C. Jones - One of the best experts on this subject based on the ideXlab platform.

  • The Chlorobenzene content of contemporary U.K. sewage sludges
    Chemosphere, 1994
    Co-Authors: Min-jian Wang, Kevin C. Jones
    Abstract:

    Twelve contemporary U.K. sewage sludges were analysed by a Soxhlet extraction, column clean-up and capillary gas chromatography method. All the Chlorobenzenes were detected in the sludges, although their content varied widely between different sewage works. Generally, Chlorobenzene concentrations decreased with increasing level of compound chlorination. Sewage sludges from industrial areas generally had higher Chlorobenzene concentrations than those from urban areas. Chlorobenzene concentrations in sludges from the same waste water treatment works over time were quite consistent.

  • The Chlorobenzene content of archived sewage sludges
    The Science of The Total Environment, 1992
    Co-Authors: Min-jian Wang, Steve P. Mcgrath, Kevin C. Jones
    Abstract:

    Chlorobenzenes in 40 anaerobically digested, lagoon dried sewage sludges were analysed by a Soxhlet extraction, Florisil clean-up and capillary gas chromatography method. These sludges had been applied to the plots of a long-term agricultural experiment from 1942 to 1961. Before application, the sewage sludges had been stored in lagoons at a sludge disposal works for about 1–5 years. Although some of the Chlorobenzenes may have been lost during this period, substantial fractions remained at the time of field application. The mean concentration of the sum of the Chlorobenzenes in the sludges was 43.7 μg/kg, with a range of 7.90–219 μg/kg. The five priority pollutants, i.e. 1,4-diChlorobenzene, 1,3-diChlorobenzene, 1,2-diChlorobenzene, hexaChlorobenzene and 1,2,4-triChlorobenzene, were the most abundant. The concentrations of chlorinated benzenes generally decreased with increased chlorine substitution, although hexaChlorobenzene and pentaChlorobenzene were present at relatively high concentrations. 1,4-DiChlorobenzene and hexaChlorobenzene increased over the period 1942–1961 in the sludges, whilst the other compounds analysed increased only from 1954 onwards. The relationship between organic matter contents and Chlorobenzene recoveries from the sewage sludges was tested by experiments and the results are discussed. The results from the archived sewage sludges provide an outline of the Chlorobenzene content in the environment of the West London area over a period when no monitoring was undertaken. Levels in the archived sludges are generally much lower, by perhaps an order of magnitude, than for contemporary samples.

Sandra García-garabal - One of the best experts on this subject based on the ideXlab platform.

  • THE TERNARY SYSTEM PROPYL PROPANOATE+ HEXANE+Chlorobenzene AT 298.15 K Excess molar enthalpies
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

  • The ternary system propyl propanoate+ hexane+Chlorobenzene at 298.15 k
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

J. Jiménez De Llano - One of the best experts on this subject based on the ideXlab platform.

  • THE TERNARY SYSTEM PROPYL PROPANOATE+ HEXANE+Chlorobenzene AT 298.15 K Excess molar enthalpies
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.

  • The ternary system propyl propanoate+ hexane+Chlorobenzene at 298.15 k
    Journal of Thermal Analysis and Calorimetry, 2002
    Co-Authors: Sonia Freire, Luisa Segade, Sandra García-garabal, J. Jiménez De Llano, M. Dominguez, Eulogio Jiménez
    Abstract:

    Excess molar enthalpies for the ternary mixture {propyl propanoate + hexane + Chlorobenzene} and the binary mixtures {propyl propanoate + Chlorobenzene} and {hexane + Chlorobenzene} were determined at the temperature 298.15 K and normal atmospheric pressure. The experimental values were measured using a Calvet microcalorimeter. Excess molar enthalpies obtained were also used to test empirical expressions for estimating ternary properties from binary results.