Custom Program

14,000,000 Leading Edge Experts on the ideXlab platform

Scan Science and Technology

Contact Leading Edge Experts & Companies

Scan Science and Technology

Contact Leading Edge Experts & Companies

The Experts below are selected from a list of 17328 Experts worldwide ranked by ideXlab platform

Robert Ritch - One of the best experts on this subject based on the ideXlab platform.

  • pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open angle glaucoma
    PLOS ONE, 2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PURPOSE Both non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness. METHODS 31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured. RESULTS Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001). Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99). However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001). Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes. CONCLUSION While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater susceptibility of the inferior radial peripapillary capillary in the pathogenesis of POAG.

  • Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PurposeBoth non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.Methods31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured.ResultsWhole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P

Yanin Suwan - One of the best experts on this subject based on the ideXlab platform.

  • pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open angle glaucoma
    PLOS ONE, 2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PURPOSE Both non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness. METHODS 31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured. RESULTS Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001). Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99). However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001). Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes. CONCLUSION While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater susceptibility of the inferior radial peripapillary capillary in the pathogenesis of POAG.

  • Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PurposeBoth non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.Methods31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured.ResultsWhole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P

Masoud Aghsaei Fard - One of the best experts on this subject based on the ideXlab platform.

  • pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open angle glaucoma
    PLOS ONE, 2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PURPOSE Both non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness. METHODS 31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured. RESULTS Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001). Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99). However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001). Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes. CONCLUSION While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater susceptibility of the inferior radial peripapillary capillary in the pathogenesis of POAG.

  • Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PurposeBoth non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.Methods31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured.ResultsWhole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P

Richard B. Rosen - One of the best experts on this subject based on the ideXlab platform.

  • pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open angle glaucoma
    PLOS ONE, 2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PURPOSE Both non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness. METHODS 31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured. RESULTS Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001). Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99). However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001). Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes. CONCLUSION While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater susceptibility of the inferior radial peripapillary capillary in the pathogenesis of POAG.

  • Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PurposeBoth non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.Methods31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured.ResultsWhole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P

Toco Y. Chui - One of the best experts on this subject based on the ideXlab platform.

  • pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open angle glaucoma
    PLOS ONE, 2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PURPOSE Both non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness. METHODS 31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured. RESULTS Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001). Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99). However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001). Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes. CONCLUSION While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater susceptibility of the inferior radial peripapillary capillary in the pathogenesis of POAG.

  • Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    2018
    Co-Authors: Masoud Aghsaei Fard, Yanin Suwan, Sasan Moghimi, Lawrence S. Geyman, Toco Y. Chui, Richard B. Rosen, Robert Ritch
    Abstract:

    PurposeBoth non-arteritic anterior ischemic optic neuropathy (NAION) and primary open-angle glaucoma (POAG) damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD) in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.Methods31 chronic NAION (>6 months after the acute event) and unaffected fellow eyes (31 subjects), 42 moderate and severe POAG eyes (27 subjects), and 77 control eyes (46 healthy subjects) were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA) at two academic institutions. Two concentric circles of diameters 1.95mm (inner) and 3.45mm (outer) were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a Custom Program. Whole-image, whole-annulus, and sectoral PCDs were measured.ResultsWhole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P