Philippe Buchler - One of the best experts on this subject based on the ideXlab platform.
-
intraoperative determination of the load Displacement Behavior of scoliotic spinal motion segments preliminary clinical results
European Spine Journal, 2012Co-Authors: Christoph Reutlinger, Carol Hasler, K Scheffler, Philippe BuchlerAbstract:Spinal fusion is a widely and successfully performed strategy for the treatment of spinal deformities and degenerative diseases. The general approach has been to stabilize the spine with implants so that a solid bony fusion between the vertebrae can develop. However, new implant designs have emerged that aim at preservation or restoration of the motion of the spinal segment. In addition to static, load sharing principles, these designs also require a profound knowledge of kinematic and dynamic properties to properly characterise the in vivo performance of the implants. To address this, an apparatus was developed that enables the intraoperative determination of the load–Displacement Behavior of spinal motion segments. The apparatus consists of a sensor-equipped distractor to measure the applied force between the transverse processes, and an optoelectronic camera to track the motion of vertebrae and the distractor. In this intraoperative trial, measurements from two patients with adolescent idiopathic scoliosis with right thoracic curves were made at four motion segments each. At a lateral bending moment of 5 N m, the mean flexibility of all eight motion segments was 0.18 ± 0.08°/N m on the convex side and 0.24 ± 0.11°/N m on the concave side. The results agree with published data obtained from cadaver studies with and without axial preload. Intraoperatively acquired data with this method may serve as an input for mathematical models and contribute to the development of new implants and treatment strategies.
Robert F Cook - One of the best experts on this subject based on the ideXlab platform.
-
load Displacement Behavior during sharp indentation of viscous elastic plastic materials
Journal of Materials Research, 2003Co-Authors: Michelle L Oyen, Robert F CookAbstract:A constitutive equation is developed for geometrically-similar sharp indentation of a material capable of elastic, viscous, and plastic deformation. The equation is based on a series of elements consisting of a quadratic (reversible) spring, a quadratic (time-dependent, reversible) dashpot, and a quadratic (time-independent, irreversible) slider-essentially modifying a model for an elastic-perfectly plastic material by incorporating a creeping component. Load-Displacement solutions to the constitutive equation are obtained for load-controlled indentation during constant loading-rate testing. A characteristic of the responses is the appearance of a forward-displacing "nose" during unloading of load-controlled systems (e.g., magnetic-coil-driven "nanoindentation" systems). Even in the absence of this nose, and the associated initial negative unloading tangent, load-Displacement traces (and hence inferred modulus and hardness values) are significantly perturbed on the addition of the viscous component. The viscous-elastic-plastic (VEP) model shows promise for obtaining material properties (elastic modulus, hardness, time-dependence) of time-dependent materials during indentation experiments.
-
load Displacement Behavior during sharp indentation of viscous elastic plastic materials
Journal of Materials Research, 2003Co-Authors: Michelle L Oyen, Robert F CookAbstract:A model is developed that describes the sharp indentation Behavior of time-dependent materials. The model constitutive equation is constructed from a series of quadratic mechanical elements, with independent viscous (dashpot), elastic (spring), and plastic (slider) responses. Solutions to this equation describe features observed under load-controlled indentation of polymers, including creep, negative unloading tangents, and loading-rate dependence. The model describes a full range of viscous–elastic–plastic responses and includes as bounding Behaviors time-independent elastic–plastic indentation (appropriate to metals and ceramics) and time-dependent viscous–elastic indentation (appropriate to elastomers). Experimental indentation traces for a range of olymers with different material properties (elastic modulus, hardness, viscosity) are econvoluted and ranked by calculated time constant. Material properties for these polymers, deconvoluted from single load–unload cycles, are used to predict the indentation load–Displacement Behavior at loading rates three times slower and faster, as well as the steady-state creep rate under fixed load.
Manohar M Panjabi - One of the best experts on this subject based on the ideXlab platform.
-
load Displacement Behavior in a distal radial fracture model the effect of simulated healing on motion
Journal of Bone and Joint Surgery American Volume, 1999Co-Authors: Scott W Wolfe, Mark Lorenze, Gregory L Austin, Carrie R Swigart, Manohar M PanjabiAbstract:External fixation of fractures of the distal end of the radius neutralizes external forces and maintains axial alignment during healing. As far as we know, there have been no biomechanical studies of the effects of early removal of the fixator in a partially healed fracture model. The purpose of the present study was to observe the load-Displacement Behavior of a distal radial fracture model in which we had simulated partial healing by injection of butyl-rubber caulk and augmented this simulated healing with Kirschner-wire fixation. Sixteen fresh-frozen hand-wrist-forearm specimens from cadavera were mounted in mid-rotation in resin pots, and a load was applied. An osteotomy was used to simulate the fracture. Relative motion at the site of the osteotomy was compared, with use of a three-dimensional Optotrak kinematic device, during physiological loading of six constructs with Kirschner-wire transfixion or outrigger fixation. In the experimental group, partial healing was simulated by injection of butyl-rubber caulk into the site of the osteotomy and testing with simulated muscle-loading was performed through a full range of motion of the wrist. No difference could be detected between the relative motion at the osteotomy sites that had been treated with standard fully augmented external fixation and that in the experimental group (p > 0.05). T test analysis revealed that motion was equivalent regardless of whether Kirschner-wire transfixion or outrigger fixation had been used (p = 0.62) and that all of the augmented constructs had significantly less relative motion than all of the nonaugmented constructs (p < 0.001). CLINICAL RELEVANCE: In clinical practice, early removal of a standard external fixator is desirable to prevent stiffness, provided that the removal does not decrease the stability of the fracture. We found that the combination of partial simulated healing and augmentation with Krischner wires in vitro provided stability that was comparable with that provided by full fixation without simulated healing in an acute-fracture model. These findings support the concept of modular disassembly of the external fixator to allow an early range of motion of the wrist.
-
load Displacement Behavior in a distal radial fracture model the effect of simulated healing on motion
Journal of Bone and Joint Surgery American Volume, 1999Co-Authors: Scott W Wolfe, Mark Lorenze, Gregory L Austin, Carrie R Swigart, Manohar M PanjabiAbstract:External fixation of fractures of the distal end of the radius neutralizes external forces and maintains axial alignment during healing. As far as we know, there have been no biomechanical studies of the effects of early removal of the fixator in a partially healed fracture model. The purpose of the present study was to observe the load-Displacement Behavior of a distal radial fracture model in which we had simulated partial healing by injection of butyl-rubber caulk and augmented this simulated healing with Kirschner-wire fixation. Sixteen fresh-frozen hand-wrist-forearm specimens from cadavera were mounted in mid-rotation in resin pots, and a load was applied. An osteotomy was used to simulate the fracture. Relative motion at the site of the osteotomy was compared, with use of a three-dimensional Optotrak kinematic device, during physiological loading of six constructs with Kirschner-wire transfixion or outrigger fixation. In the experimental group, partial healing was simulated by injection of butyl-rubber caulk into the site of the osteotomy and testing with simulated muscle-loading was performed through a full range of motion of the wrist. No difference could be detected between the relative motion at the osteotomy sites that had been treated with standard fully augmented external fixation and that in the experimental group (p > 0.05). T test analysis revealed that motion was equivalent regardless of whether Kirschner-wire transfixion or outrigger fixation had been used (p = 0.62) and that all of the augmented constructs had significantly less relative motion than all of the nonaugmented constructs (p < 0.001).
Christoph Reutlinger - One of the best experts on this subject based on the ideXlab platform.
-
intraoperative determination of the load Displacement Behavior of scoliotic spinal motion segments preliminary clinical results
European Spine Journal, 2012Co-Authors: Christoph Reutlinger, Carol Hasler, K Scheffler, Philippe BuchlerAbstract:Spinal fusion is a widely and successfully performed strategy for the treatment of spinal deformities and degenerative diseases. The general approach has been to stabilize the spine with implants so that a solid bony fusion between the vertebrae can develop. However, new implant designs have emerged that aim at preservation or restoration of the motion of the spinal segment. In addition to static, load sharing principles, these designs also require a profound knowledge of kinematic and dynamic properties to properly characterise the in vivo performance of the implants. To address this, an apparatus was developed that enables the intraoperative determination of the load–Displacement Behavior of spinal motion segments. The apparatus consists of a sensor-equipped distractor to measure the applied force between the transverse processes, and an optoelectronic camera to track the motion of vertebrae and the distractor. In this intraoperative trial, measurements from two patients with adolescent idiopathic scoliosis with right thoracic curves were made at four motion segments each. At a lateral bending moment of 5 N m, the mean flexibility of all eight motion segments was 0.18 ± 0.08°/N m on the convex side and 0.24 ± 0.11°/N m on the concave side. The results agree with published data obtained from cadaver studies with and without axial preload. Intraoperatively acquired data with this method may serve as an input for mathematical models and contribute to the development of new implants and treatment strategies.
Michelle L Oyen - One of the best experts on this subject based on the ideXlab platform.
-
load Displacement Behavior during sharp indentation of viscous elastic plastic materials
Journal of Materials Research, 2003Co-Authors: Michelle L Oyen, Robert F CookAbstract:A constitutive equation is developed for geometrically-similar sharp indentation of a material capable of elastic, viscous, and plastic deformation. The equation is based on a series of elements consisting of a quadratic (reversible) spring, a quadratic (time-dependent, reversible) dashpot, and a quadratic (time-independent, irreversible) slider-essentially modifying a model for an elastic-perfectly plastic material by incorporating a creeping component. Load-Displacement solutions to the constitutive equation are obtained for load-controlled indentation during constant loading-rate testing. A characteristic of the responses is the appearance of a forward-displacing "nose" during unloading of load-controlled systems (e.g., magnetic-coil-driven "nanoindentation" systems). Even in the absence of this nose, and the associated initial negative unloading tangent, load-Displacement traces (and hence inferred modulus and hardness values) are significantly perturbed on the addition of the viscous component. The viscous-elastic-plastic (VEP) model shows promise for obtaining material properties (elastic modulus, hardness, time-dependence) of time-dependent materials during indentation experiments.
-
load Displacement Behavior during sharp indentation of viscous elastic plastic materials
Journal of Materials Research, 2003Co-Authors: Michelle L Oyen, Robert F CookAbstract:A model is developed that describes the sharp indentation Behavior of time-dependent materials. The model constitutive equation is constructed from a series of quadratic mechanical elements, with independent viscous (dashpot), elastic (spring), and plastic (slider) responses. Solutions to this equation describe features observed under load-controlled indentation of polymers, including creep, negative unloading tangents, and loading-rate dependence. The model describes a full range of viscous–elastic–plastic responses and includes as bounding Behaviors time-independent elastic–plastic indentation (appropriate to metals and ceramics) and time-dependent viscous–elastic indentation (appropriate to elastomers). Experimental indentation traces for a range of olymers with different material properties (elastic modulus, hardness, viscosity) are econvoluted and ranked by calculated time constant. Material properties for these polymers, deconvoluted from single load–unload cycles, are used to predict the indentation load–Displacement Behavior at loading rates three times slower and faster, as well as the steady-state creep rate under fixed load.