The Experts below are selected from a list of 132 Experts worldwide ranked by ideXlab platform
Louis M Ferreira - One of the best experts on this subject based on the ideXlab platform.
-
quantitative computed tomography qct derived bone mineral Density bmd in finite element studies a review of the literature
Journal of Experimental Orthopaedics, 2016Co-Authors: Nikolas K Knowles, Jacob M Reeves, Louis M FerreiraAbstract:Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral Density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and Density-mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT Equivalent Density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common Density-modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented. Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K2HPO4) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K2HPO4 and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or Density-modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics. This review assessed the current state of QCT-based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models.
Kajetan Poprawski - One of the best experts on this subject based on the ideXlab platform.
-
a large asymptomatic pericardial cyst in the apical region
Kardiologia Polska, 2012Co-Authors: Ireneusz Jedlinski, Maria Jamrozekjedlinska, Pawel Bugajski, Marek Bartkowiak, Marek Slomczynski, Kajetan PoprawskiAbstract:We presented a case of the large asymptomatic pericardial cyst localised near cardiac apex, filled with fluid of water-Equivalent Density. The cyst was detected accidentally during transthoracic echocardiography and confirmed by 64-slice multi-detector computed tomography. Repeated transthoracic echocardiography was recommened.
-
duza bezobjawowa torbiel osierdzia w okolicy koniuszka serca a large asymptomatic pericardial cyst in the apical region
2012Co-Authors: Maria Jamrozek, Pawel Bugajski, Marek Bartkowiak, Marek Slomczynski, Kajetan Poprawski, Uniwersytet MedycznyAbstract:We presented a case of the large asymptomatic pericardial cyst localised near cardiac apex, filled with fluid of water-Equivalent Density. The cyst was detected accidentally during transthoracic echocardiography and confirmed by 64-slice multi-detector computed tomography. Repeated transthoracic echocardiography was recommened.
Nikolas K Knowles - One of the best experts on this subject based on the ideXlab platform.
-
quantitative computed tomography qct derived bone mineral Density bmd in finite element studies a review of the literature
Journal of Experimental Orthopaedics, 2016Co-Authors: Nikolas K Knowles, Jacob M Reeves, Louis M FerreiraAbstract:Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral Density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and Density-mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT Equivalent Density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common Density-modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented. Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K2HPO4) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K2HPO4 and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or Density-modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics. This review assessed the current state of QCT-based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models.
Uniwersytet Medyczny - One of the best experts on this subject based on the ideXlab platform.
-
duza bezobjawowa torbiel osierdzia w okolicy koniuszka serca a large asymptomatic pericardial cyst in the apical region
2012Co-Authors: Maria Jamrozek, Pawel Bugajski, Marek Bartkowiak, Marek Slomczynski, Kajetan Poprawski, Uniwersytet MedycznyAbstract:We presented a case of the large asymptomatic pericardial cyst localised near cardiac apex, filled with fluid of water-Equivalent Density. The cyst was detected accidentally during transthoracic echocardiography and confirmed by 64-slice multi-detector computed tomography. Repeated transthoracic echocardiography was recommened.
Pawel Bugajski - One of the best experts on this subject based on the ideXlab platform.
-
a large asymptomatic pericardial cyst in the apical region
Kardiologia Polska, 2012Co-Authors: Ireneusz Jedlinski, Maria Jamrozekjedlinska, Pawel Bugajski, Marek Bartkowiak, Marek Slomczynski, Kajetan PoprawskiAbstract:We presented a case of the large asymptomatic pericardial cyst localised near cardiac apex, filled with fluid of water-Equivalent Density. The cyst was detected accidentally during transthoracic echocardiography and confirmed by 64-slice multi-detector computed tomography. Repeated transthoracic echocardiography was recommened.
-
duza bezobjawowa torbiel osierdzia w okolicy koniuszka serca a large asymptomatic pericardial cyst in the apical region
2012Co-Authors: Maria Jamrozek, Pawel Bugajski, Marek Bartkowiak, Marek Slomczynski, Kajetan Poprawski, Uniwersytet MedycznyAbstract:We presented a case of the large asymptomatic pericardial cyst localised near cardiac apex, filled with fluid of water-Equivalent Density. The cyst was detected accidentally during transthoracic echocardiography and confirmed by 64-slice multi-detector computed tomography. Repeated transthoracic echocardiography was recommened.