The Experts below are selected from a list of 6 Experts worldwide ranked by ideXlab platform

Uri Gophna - One of the best experts on this subject based on the ideXlab platform.

  • Specific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
    Applied Sciences, 2020
    Co-Authors: Keren Yanuka-golub, Leah Reshef, Judith Rishpon, Uri Gophna
    Abstract:

    Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.

Keren Yanuka-golub - One of the best experts on this subject based on the ideXlab platform.

  • Specific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
    Applied Sciences, 2020
    Co-Authors: Keren Yanuka-golub, Leah Reshef, Judith Rishpon, Uri Gophna
    Abstract:

    Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.

Leah Reshef - One of the best experts on this subject based on the ideXlab platform.

  • Specific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
    Applied Sciences, 2020
    Co-Authors: Keren Yanuka-golub, Leah Reshef, Judith Rishpon, Uri Gophna
    Abstract:

    Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.

Judith Rishpon - One of the best experts on this subject based on the ideXlab platform.

  • Specific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
    Applied Sciences, 2020
    Co-Authors: Keren Yanuka-golub, Leah Reshef, Judith Rishpon, Uri Gophna
    Abstract:

    Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.

William E. Fantegrossi - One of the best experts on this subject based on the ideXlab platform.

  • Phencyclidine-like in vivo effects of methoxetamine in mice and rats.
    Neuropharmacology, 2017
    Co-Authors: Michael D. Berquist, William S. Hyatt, Jonathan Bauer-erickson, Brenda M. Gannon, Andrew P. Norwood, William E. Fantegrossi
    Abstract:

    Methoxetamine (MXE) is a novel drug of abuse that is structurally similar to phencyclidine (PCP). In the present study, rats were trained to discriminate PCP from saline and substitution tests were performed with arylcyclohexylamines PCP, Eticyclidine (PCE), tenocyclidine (TCP), and MXE. PCP and PCE engendered PCP-lever selection in all subjects, whereas MXE and TCP produced PCP-lever selection in animals that did not display behavioral disruption. Last, the substituted tryptamine dipropyltryptamine (DPT) produced moderate PCP-lever selection and elicited behavioral disruption in all subjects at the highest dose tested. Immediately following the final substitution test in the drug discrimination experiment, the same rats and a separate group of experimentally-naive rats were implanted with osmotic mini-pumps delivering continuous PCP infusions for 11 days. Consistent with PCP withdrawal, disruption of food-maintained operant responding was observed when the pumps were removed, but cumulative MXE administration dose-dependently reversed this effect. A third group of rats self-administered several unit doses of PCP and MXE. Results of the self-administration tests revealed that MXE was a less effective reinforcer than PCP. Lastly, mice were implanted with radiotelemetry probes to simultaneously monitor thermoregulatory and locomotor responses following injections of PCP, PCE, or MXE. All three arylcyclohexylamines elicited dose-dependent hypothermic effects, but only PCP produced increases in locomotor activity. Together, these findings indicate that MXE elicits PCP-like interoceptive effects, but reduced reinforcing and locomotor stimulant effects in vivo.