Ti Bai - One of the best experts on this subject based on the ideXlab platform.

  • a practical cone beam ct scatter correction method with optimized monte carlo simulations for image guided Radiation Therapy
    Physics in Medicine and Biology, 2015
    Co-Authors: Ti Bai, Hao Yan, Luo Ouyang, Arnold Pompos, Jing Wang, Linghong Zhou, Steve B Jiang, Xun Jia
    Abstract:

    Cone-beam CT (CBCT) has become the standard image guidance tool for patient setup in Image-Guided Radiation Therapy. However, due to its large illumination field, scattered photons severely degrade its image quality. While kernel-based scatter correction methods have been used routinely in the clinic, it is still desirable to develop Monte Carlo (MC) simulation-based methods due to their accuracy. However, the high computational burden of the MC method has prevented routine clinical application. This paper reports our recent development of a practical method of MC-based scatter estimation and removal for CBCT. In contrast with conventional MC approaches that estimate scatter signals using a scatter-contaminated CBCT image, our method used a planning CT image for MC simulation, which has the advantages of accurate image intensity and absence of image truncation. In our method, the planning CT was first rigidly registered with the CBCT. Scatter signals were then estimated via MC simulation. After scatter signals were removed from the raw CBCT projections, a corrected CBCT image was reconstructed. The entire workflow was implemented on a GPU platform for high computational efficiency. Strategies such as projection denoising, CT image downsampling, and interpolation along the angular direction were employed to further enhance the calculation speed. We studied the impact of key parameters in the workflow on the resulting accuracy and efficiency, based on which the optimal parameter values were determined. Our method was evaluated in numerical simulation, phantom, and real patient cases. In the simulation cases, our method reduced mean HU errors from 44 to 3 HU and from 78 to 9 HU in the full-fan and the half-fan cases, respectively. In both the phantom and the patient cases, image artifacts caused by scatter, such as ring artifacts around the bowtie area, were reduced. With all the techniques employed, we achieved computation time of less than 30 s including the time for both the scatter estimation and CBCT reconstruction steps. The efficacy of our method and its high computational efficiency make our method attractive for clinical use.

Guanghong Chen - One of the best experts on this subject based on the ideXlab platform.

  • prior image constrained scatter correction in cone beam computed tomography image guided Radiation Therapy
    Physics in Medicine and Biology, 2011
    Co-Authors: Stephen Brunner, Brian E Nett, R Tolakanahalli, Guanghong Chen
    Abstract:

    X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered Radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the image reconstruction process. In this paper, we extend this idea to correct scatter-induced shading artifacts in cone-beam CT Image-Guided Radiation Therapy. Specifically, this paper presents a new scatter correction algorithm which uses a prior image with low scatter artifacts to reduce shading artifacts in cone-beam CT images acquired under conditions of high scatter. The proposed correction algorithm begins with an empirical hypothesis that the target image can be written as a weighted summation of a series of basis images that are generated by raising the raw cone-beam projection data to different powers, and then, reconstructing using the standard filtered backprojection algorithm. The weight for each basis image is calculated by minimizing the difference between the target image and the prior image. The performance of the scatter correction algorithm is qualitatively and quantitatively evaluated through phantom studies using a Varian 2100 EX System with an on-board imager. Results show that the proposed scatter correction algorithm using a prior image with low scatter artifacts can substantially mitigate scatter-induced shading artifacts in both full-fan and half-fan modes.

Takeaki Ishihara - One of the best experts on this subject based on the ideXlab platform.

  • Novel artifact-robust and highly visible zinc solid fiducial marker for kilovoltage x-ray Image-Guided Radiation Therapy.
    Medical physics, 2020
    Co-Authors: Tianyuan Wang, Sachiko Inubushi, Naoko Ikeo, Toshiji Mukai, Keisuke Okumura, Hiroaki Akasaka, Ryuichi Yada, Kenji Yoshida, Daisuke Miyawaki, Takeaki Ishihara
    Abstract:

    Purpose To develop a novel biocompatible solid fiducial marker that prevents radiopaque imaging artifacts and also maintains high imaging contrast for kilovoltage x-ray Image-Guided Radiation Therapy. Methods The fiducial marker was made of pure zinc. An in-house water-equivalent phantom was designed to evaluate artifacts and visibility under various simulated treatment scenarios. Image artifacts were quantitatively assessed in terms of the metal artifact index (MAI) on kilovoltage computed tomography (CT) and cone-beam CT (CBCT) scans. Marker visibility was evaluated on two types of kilovoltage planar x-ray images in terms of the contrast-to-background ratio (CBR). Comparisons with a conventional gold fiducial marker were conducted. Results The use of zinc rather than a gold marker mitigates imaging artifacts. The MAI near the zinc marker decreased by 76, 79, and 77 % in CT, and by 77 (81), 74 (80), and 79 (85) % in CBCT full-fan (half-fan) scans, when using one-, two-, and three-marker phantom settings, respectively. The high-contrast part of the zinc marker exhibited CBRs above 2.00 for 28/32 exposures under four (lung, tissue, low-density bone, and high-density bone) different simulation scenarios, making its visibility comparable to that of the gold marker (30/32 exposures with CBRs > 2.00). Conclusions We developed a biocompatible, artifact-robust, and highly visible solid zinc fiducial marker. Although further evaluation is needed in clinical settings, our findings suggest its feasibility and benefits for kilovoltage x-ray Image-Guided Radiation Therapy.

Xun Jia - One of the best experts on this subject based on the ideXlab platform.

  • a practical cone beam ct scatter correction method with optimized monte carlo simulations for image guided Radiation Therapy
    Physics in Medicine and Biology, 2015
    Co-Authors: Ti Bai, Hao Yan, Luo Ouyang, Arnold Pompos, Jing Wang, Linghong Zhou, Steve B Jiang, Xun Jia
    Abstract:

    Cone-beam CT (CBCT) has become the standard image guidance tool for patient setup in Image-Guided Radiation Therapy. However, due to its large illumination field, scattered photons severely degrade its image quality. While kernel-based scatter correction methods have been used routinely in the clinic, it is still desirable to develop Monte Carlo (MC) simulation-based methods due to their accuracy. However, the high computational burden of the MC method has prevented routine clinical application. This paper reports our recent development of a practical method of MC-based scatter estimation and removal for CBCT. In contrast with conventional MC approaches that estimate scatter signals using a scatter-contaminated CBCT image, our method used a planning CT image for MC simulation, which has the advantages of accurate image intensity and absence of image truncation. In our method, the planning CT was first rigidly registered with the CBCT. Scatter signals were then estimated via MC simulation. After scatter signals were removed from the raw CBCT projections, a corrected CBCT image was reconstructed. The entire workflow was implemented on a GPU platform for high computational efficiency. Strategies such as projection denoising, CT image downsampling, and interpolation along the angular direction were employed to further enhance the calculation speed. We studied the impact of key parameters in the workflow on the resulting accuracy and efficiency, based on which the optimal parameter values were determined. Our method was evaluated in numerical simulation, phantom, and real patient cases. In the simulation cases, our method reduced mean HU errors from 44 to 3 HU and from 78 to 9 HU in the full-fan and the half-fan cases, respectively. In both the phantom and the patient cases, image artifacts caused by scatter, such as ring artifacts around the bowtie area, were reduced. With all the techniques employed, we achieved computation time of less than 30 s including the time for both the scatter estimation and CBCT reconstruction steps. The efficacy of our method and its high computational efficiency make our method attractive for clinical use.

Xiaochuan Pan - One of the best experts on this subject based on the ideXlab platform.

  • Algorithm-enabled exploration of image-quality potential of cone-beam CT in Image-Guided Radiation Therapy
    Physics in medicine and biology, 2015
    Co-Authors: Xiao Han, Junguo Bian, E Pearson, Charles A. Pelizzari, Hania A. Al-hallaq, Emil Y. Sidky, Xiaochuan Pan
    Abstract:

    Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in Image-Guided Radiation Therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data, optimization-based reconstruction has also been investigated for OBI CBCT. An optimization-based reconstruction involves numerous parameters, which can significantly impact reconstruction properties (or utility). The success of an optimization-based reconstruction for a particular class of practical applications thus relies strongly on appropriate selection of parameter values. In the work, we focus on tailoring the constrained-TV-minimization-based reconstruction, an optimization-based reconstruction previously shown of some potential for CBCT imaging conditions of practical interest, to OBI imaging through appropriate selection of parameter values. In particular, for given real data of phantoms and patient collected with OBI CBCT, we first devise utility metrics specific to OBI-quality-assurance tasks and then apply them to guiding the selection of parameter values in constrained-TV-minimization-based reconstruction. The study results show that the reconstructions are with improvement, relative to clinical FDK reconstruction, in both visualization and quantitative assessments in terms of the devised utility metrics.

  • region of interest image reconstruction with intensity weighting in circular cone beam ct for image guided Radiation Therapy
    Medical Physics, 2009
    Co-Authors: Seungryong Cho, E Pearson, Charles A. Pelizzari, Xiaochuan Pan
    Abstract:

    Imaging plays a vital role in Radiation Therapy and with recent advances in technology considerable emphasis has been placed on cone-beam CT (CBCT). Attaching a kV x-ray source and a flat panel detector directly to the linear accelerator gantry has enabled progress in target localization techniques, which can include daily CBCT setup scans for some treatments. However, with an increasing number of CT scans there is also an increasing concern for patient exposure. An intensity-weighted region-of-interest (IWROI) technique, which has the potential to greatly reduce CBCT dose, in conjunction with the chord-based backprojection-filtration (BPF) reconstruction algorithm, has been developed and its feasibility in clinical use is demonstrated in this article. A nonuniform filter is placed in the x-ray beam to create regions of two different beam intensities. In this manner, regions outside the target area can be given a reduced dose but still visualized with a lower contrast to noise ratio. Image artifacts due to transverse data truncation, which would have occurred in conventional reconstruction algorithms, are avoided and image noise levels of the low- and high-intensity regions are well controlled by use of the chord-based BPF reconstruction algorithm. The proposed IWROI technique can play an important role in Image-Guided Radiation Therapy.