The Experts below are selected from a list of 9930 Experts worldwide ranked by ideXlab platform
Philippe Dubuisson - One of the best experts on this subject based on the ideXlab platform.
-
lidar multiple scattering factors inferred from calipso lidar and iir retrievals of semi transparent cirrus cloud optical depths over oceans
Atmospheric Measurement Techniques, 2015Co-Authors: Anne Garnier, Jacques Pelon, Mark A Vaughan, D M Winker, C R Trepte, Philippe DubuissonAbstract:Abstract. Cirrus cloud absorption optical depths retrieved at 12.05 μm are compared to extinction optical depths retrieved at 0.532 μm from perfectly co-located observations of single-layered semi-transparent cirrus over ocean made by the Imaging Infrared Radiometer (IIR) and the Cloud and Aerosol Lidar with Orthogonal Polarization (CALIOP) flying on board the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations) satellite. IIR Infrared absorption optical depths are compared to CALIOP visible extinction optical depths when the latter can be directly derived from the measured apparent two-way transmittance through the cloud. An evaluation of the CALIOP multiple scattering factor is inferred from these comparisons after assessing and correcting biases in IIR and CALIOP optical depths reported in version 3 data products. In particular, the blackbody radiance taken in the IIR version 3 algorithm is evaluated, and IIR retrievals are corrected accordingly. Numerical simulations and IIR retrievals of ice crystal sizes suggest that the ratios of CALIOP extinction and IIR absorption optical depths should remain roughly constant with respect to temperature. Instead, these ratios are found to increase quasi-linearly by about 40 % as the temperature at the layer centroid altitude decreases from 240 to 200 K. It is discussed that this behavior can be explained by variations of the multiple scattering factor ηT applied to correct the measured apparent two-way transmittance for contribution of forward-scattering. While the CALIOP version 3 retrievals hold ηT fixed at 0.6, this study shows that ηT varies with temperature (and hence cloud particle size) from ηT = 0.8 at 200 K to ηT = 0.5 at 240 K for single-layered semi-transparent cirrus clouds with optical depth larger than 0.3. The revised parameterization of ηT introduces a concomitant temperature dependence in the simultaneously derived CALIOP lidar ratios that is consistent with observed changes in CALIOP depolarization ratios and particle habits derived from IIR measurements.
-
retrieval of cloud properties using calipso imaging Infrared Radiometer part i effective emissivity and optical depth
Journal of Applied Meteorology and Climatology, 2012Co-Authors: Anne Garnier, Jacques Pelon, Philippe Dubuisson, Michael Faivre, Olivier Chomette, Nicolas Pascal, David P KratzAbstract:The paper describes the operational analysis of the Imaging Infrared Radiometer (IIR) data, which have been collected in the framework of the Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) mission for the purpose of retrieving high-altitude (above 7 km) cloud effective emissivity and optical depth that can be used in synergy with the vertically resolved Cloud–Aerosol Lidar with Orthogonal Polarization (CALIOP) collocated observations. After an IIR scene classification is built under the CALIOP track, the analysis is applied to features detected by CALIOP when found alone in the atmospheric column or when CALIOP identifies an opaque layer underneath. The fast-calculation radiative transfer (FASRAD) model fed by ancillary meteorological and surface data is used to compute the different components involved in the effective emissivity retrievals under the CALIOP track. The track analysis is extended to the IIR swath using homogeneity criteria that are based on radiative equivalence. The effective optical depth at 12.05 m mi s shown to be a good proxy for about one-half of the cloud optical depth, allowing direct comparisons with other databases in the visible spectrum. A step-by-step quantitative sensitivity and performance analysis is provided. The method is validated through comparisons of collocated IIR and CALIOP optical depths for elevated single-layered semitransparent cirrus clouds, showing excellent agreement (within 20%) for values ranging from 1 down to 0.05. Uncertainties have been determined from the identified error sources. The optical depth distribution of semitransparent clouds is found to have a nearly exponential shape with a mean value of about 0.5–0.6.
-
sensitivity of thermal Infrared radiation at the top of the atmosphere and the surface to ice cloud microphysics
Journal of Applied Meteorology and Climatology, 2008Co-Authors: Philippe Dubuisson, Jacques Pelon, Vincent Giraud, Bertrand Cadet, Ping YangAbstract:Abstract This paper reports on the sensitivity of the brightness temperatures associated with radiances at the surface and the top of the atmosphere, simulated for the Imaging Infrared Radiometer (IIR) 8.7-, 10.6-, and 12-μm channels under ice cloudy conditions, to the optical and microphysical properties of ice clouds. The 10.6- and 12-μm channels allow simultaneous retrieval of ice cloud optical thickness and effective particle size (Deff) less than 100 μm. It is illustrated that the particle shape and size distributions of ice crystals have noticeable effects on the brightness temperatures. Using the split window technique based on the 10.6- and 12-μm channels in conjunction with cloud properties assumed a priori, the authors show that the influence of the cloud microphysical properties can lead to differences on the order of ±10% and ±25% in retrieved effective particle sizes for small (Deff 40 μm), respectively. The impact of cloud model on retrieved optical thick...
Lin Chen - One of the best experts on this subject based on the ideXlab platform.
-
Consistent Calibration of VIRR Reflective Solar Channels Onboard FY-3A, FY-3B, and FY-3C Using a Multisite Calibration Method
Remote Sensing, 2018Co-Authors: Ling Wang, Lin ChenAbstract:The FengYun-3 (FY-3) Visible Infrared Radiometer (VIRR), along with its predecessor, the Multispectral Visible Infrared Scanning Radiometer (MVISR), onboard the FY-1C and FY-1D, has collected continuous daily global observations for 18 years. Achieving accurate and consistent calibration for VIRR reflective solar bands (RSBs) has been challenging, as there is no onboard calibrator and the frequency of in situ vicarious calibration is limited. In this study, a new set of reflectance calibration coefficients were derived for RSBs of the FY-3A, FY-3B, and FY-3C VIRRs using a multisite (MST) calibration method. This method is an extension of a previous MST calibration method, which relies on radiative transfer modeling over the multiple stable earth sites, and no synchronous in situ measurements are needed; hence, it can be used to update the VIRR calibration on a daily basis. The on-orbit radiometric changes of the VIRR onboard the FY-3 series were assessed based on analyses of new sets of calibration slopes. Then, all recalibrated VIRR reflectance data over Libya 4, the most frequently used stable Earth site, were compared with those provided from the Level 1B (L1B) product. Additional validation was performed by comparing the recalibrated VIRR data with those derived from radiative transfer simulations using measurements from automatic calibration instruments in Dunhuang. The results indicate that the radiometric response changes of the VIRRs onboard FY-3A and FY-3B were larger than those of FY-3C VIRR and were wavelength dependent. The current approach can provide consistent VIRR reflectances across different FY-3 satellite platforms. After recalibration, differences in top-of-atmosphere (TOA) reflectance data across different VIRRs during the whole lifetime decreased from 5–10% to less than 3%. The comparison with the automatic calibration method indicates that MST calibration shows good accuracy and lower temporal oscillations.
-
assessment and correction of on orbit radiometric calibration for fy 3 virr thermal Infrared channels
Remote Sensing, 2014Co-Authors: Lin Chen, Liyang Zhang, Peng ZhangAbstract:FengYun-3 (FY-3) Visible Infrared Radiometer (VIRR), along with its predecessor, Multispectral Visible Infrared Scanning Radiometer (MVISR), onboard FY-1C&D have had continuous global observation more than 14 years. This data record is valuable for weather prediction, climate monitoring, and environment research. Data quality is vital for satellite data assimilations in Numerical Weather Prediction (NWP) and quantitative remote sensing applications. In this paper, the accuracies of radiometric calibration for VIRR onboard FY-3A and FY-3B, in thermal Infrared (TIR) channels, are evaluated using the Low Earth Orbit (LEO)-LEO simultaneous nadir overpass intercalibration method. Hyperspectral and high-quality observations from Infrared Atmosphere Sounding Instrument (IASI) onboard METOP-A are used as reference. The biases of VIRR measurements with respect to IASI over one-and-a-half years indicate that the TIR calibration accuracy of FY-3B VIRR is better than that of FY-3A VIRR. The brightness temperature (BT) measured by FY-3A/VIRR is cooler than that measured by IASI with monthly mean biases ranging from −2 K to −1 K for channel 4 and −1 K to 0.2 K for channel 5. Measurements from FY-3B/VIRR are more consistent with that from IASI, and the annual mean biases are 0.84 ± 0.16 K and −0.66 ± 0.18 K for channels 4 and 5, respectively. The BT biases of FY-3A/VIRR show scene temperature-dependence and seasonal variation, which are not found from FY-3B/VIRR BT biases. The temperature-dependent biases are shown to be attributed to the nonlinearity of detectors. New nonlinear correction coefficients of FY-3A/VIRR TIR channels are reevaluated using various collocation samples. Verification results indicate that the use of the new nonlinear correction can greatly correct the scene temperature-dependent and systematic biases.
Jacques Pelon - One of the best experts on this subject based on the ideXlab platform.
-
lidar multiple scattering factors inferred from calipso lidar and iir retrievals of semi transparent cirrus cloud optical depths over oceans
Atmospheric Measurement Techniques, 2015Co-Authors: Anne Garnier, Jacques Pelon, Mark A Vaughan, D M Winker, C R Trepte, Philippe DubuissonAbstract:Abstract. Cirrus cloud absorption optical depths retrieved at 12.05 μm are compared to extinction optical depths retrieved at 0.532 μm from perfectly co-located observations of single-layered semi-transparent cirrus over ocean made by the Imaging Infrared Radiometer (IIR) and the Cloud and Aerosol Lidar with Orthogonal Polarization (CALIOP) flying on board the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations) satellite. IIR Infrared absorption optical depths are compared to CALIOP visible extinction optical depths when the latter can be directly derived from the measured apparent two-way transmittance through the cloud. An evaluation of the CALIOP multiple scattering factor is inferred from these comparisons after assessing and correcting biases in IIR and CALIOP optical depths reported in version 3 data products. In particular, the blackbody radiance taken in the IIR version 3 algorithm is evaluated, and IIR retrievals are corrected accordingly. Numerical simulations and IIR retrievals of ice crystal sizes suggest that the ratios of CALIOP extinction and IIR absorption optical depths should remain roughly constant with respect to temperature. Instead, these ratios are found to increase quasi-linearly by about 40 % as the temperature at the layer centroid altitude decreases from 240 to 200 K. It is discussed that this behavior can be explained by variations of the multiple scattering factor ηT applied to correct the measured apparent two-way transmittance for contribution of forward-scattering. While the CALIOP version 3 retrievals hold ηT fixed at 0.6, this study shows that ηT varies with temperature (and hence cloud particle size) from ηT = 0.8 at 200 K to ηT = 0.5 at 240 K for single-layered semi-transparent cirrus clouds with optical depth larger than 0.3. The revised parameterization of ηT introduces a concomitant temperature dependence in the simultaneously derived CALIOP lidar ratios that is consistent with observed changes in CALIOP depolarization ratios and particle habits derived from IIR measurements.
-
retrieval of cloud properties using calipso imaging Infrared Radiometer part i effective emissivity and optical depth
Journal of Applied Meteorology and Climatology, 2012Co-Authors: Anne Garnier, Jacques Pelon, Philippe Dubuisson, Michael Faivre, Olivier Chomette, Nicolas Pascal, David P KratzAbstract:The paper describes the operational analysis of the Imaging Infrared Radiometer (IIR) data, which have been collected in the framework of the Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) mission for the purpose of retrieving high-altitude (above 7 km) cloud effective emissivity and optical depth that can be used in synergy with the vertically resolved Cloud–Aerosol Lidar with Orthogonal Polarization (CALIOP) collocated observations. After an IIR scene classification is built under the CALIOP track, the analysis is applied to features detected by CALIOP when found alone in the atmospheric column or when CALIOP identifies an opaque layer underneath. The fast-calculation radiative transfer (FASRAD) model fed by ancillary meteorological and surface data is used to compute the different components involved in the effective emissivity retrievals under the CALIOP track. The track analysis is extended to the IIR swath using homogeneity criteria that are based on radiative equivalence. The effective optical depth at 12.05 m mi s shown to be a good proxy for about one-half of the cloud optical depth, allowing direct comparisons with other databases in the visible spectrum. A step-by-step quantitative sensitivity and performance analysis is provided. The method is validated through comparisons of collocated IIR and CALIOP optical depths for elevated single-layered semitransparent cirrus clouds, showing excellent agreement (within 20%) for values ranging from 1 down to 0.05. Uncertainties have been determined from the identified error sources. The optical depth distribution of semitransparent clouds is found to have a nearly exponential shape with a mean value of about 0.5–0.6.
-
sensitivity of thermal Infrared radiation at the top of the atmosphere and the surface to ice cloud microphysics
Journal of Applied Meteorology and Climatology, 2008Co-Authors: Philippe Dubuisson, Jacques Pelon, Vincent Giraud, Bertrand Cadet, Ping YangAbstract:Abstract This paper reports on the sensitivity of the brightness temperatures associated with radiances at the surface and the top of the atmosphere, simulated for the Imaging Infrared Radiometer (IIR) 8.7-, 10.6-, and 12-μm channels under ice cloudy conditions, to the optical and microphysical properties of ice clouds. The 10.6- and 12-μm channels allow simultaneous retrieval of ice cloud optical thickness and effective particle size (Deff) less than 100 μm. It is illustrated that the particle shape and size distributions of ice crystals have noticeable effects on the brightness temperatures. Using the split window technique based on the 10.6- and 12-μm channels in conjunction with cloud properties assumed a priori, the authors show that the influence of the cloud microphysical properties can lead to differences on the order of ±10% and ±25% in retrieved effective particle sizes for small (Deff 40 μm), respectively. The impact of cloud model on retrieved optical thick...
Bo Zhong - One of the best experts on this subject based on the ideXlab platform.
-
evaluation of land surface temperature retrieval from fy 3b virr data in an arid area of northwestern china
Remote Sensing, 2015Co-Authors: Jinxiong Jiang, Qinhuo Liu, Heshun Wang, Biao Cao, Bo ZhongAbstract:This paper uses the refined Generalized Split-Window (GSW) algorithm to derive the land surface temperature (LST) from the data acquired by the Visible and Infrared Radiometer on FengYun 3B (FY-3B/VIRR). The coefficients in the GSW algorithm corresponding to a series of overlapping ranges for the mean emissivity, the atmospheric Water Vapor Content (WVC), and the LST are derived using a statistical regression method from the numerical values simulated with an accurate atmospheric radiative transfer model MODTRAN 4 over a wide range of atmospheric and surface conditions. The GSW algorithm is applied to retrieve LST from FY-3B/VIRR data in an arid area in northwestern China. Three emissivity databases are used to evaluate the accuracy of different emissivity databases for LST retrieval, including the ASTER Global Emissivity Database (ASTER_GED) at a 1-km spatial resolution (AG1km), an average of twelve ASTER emissivity data in the 2012 summer and emissivity spectra extracted from spectral libraries. The LSTs retrieved from the three emissivity databases are evaluated with ground-measured LST at four barren surface sites from June 2012 to December 2013 collected during the HiWATER field campaign. The results indicate that using emissivity
-
Evaluation of Land Surface Temperature Retrieval from FY-3B/VIRR Data in an Arid Area of Northwestern China
MDPI AG, 2015Co-Authors: Jinxiong Jiang, Qinhuo Liu, Heshun Wang, Biao Cao, Bo ZhongAbstract:This paper uses the refined Generalized Split-Window (GSW) algorithm to derive the land surface temperature (LST) from the data acquired by the Visible and Infrared Radiometer on FengYun 3B (FY-3B/VIRR). The coefficients in the GSW algorithm corresponding to a series of overlapping ranges for the mean emissivity, the atmospheric Water Vapor Content (WVC), and the LST are derived using a statistical regression method from the numerical values simulated with an accurate atmospheric radiative transfer model MODTRAN 4 over a wide range of atmospheric and surface conditions. The GSW algorithm is applied to retrieve LST from FY-3B/VIRR data in an arid area in northwestern China. Three emissivity databases are used to evaluate the accuracy of different emissivity databases for LST retrieval, including the ASTER Global Emissivity Database (ASTER_GED) at a 1-km spatial resolution (AG1km), an average of twelve ASTER emissivity data in the 2012 summer and emissivity spectra extracted from spectral libraries. The LSTs retrieved from the three emissivity databases are evaluated with ground-measured LST at four barren surface sites from June 2012 to December 2013 collected during the HiWATER field campaign. The results indicate that using emissivity extracted from ASTER_GED can achieve the highest accuracy with an average bias of 1.26 and −0.04 K and an average root mean square error (RMSE) of 2.69 and 1.38 K for the four sites during daytime and nighttime, respectively. This result indicates that ASTER_GED is a useful emissivity database for generating global LST products from different thermal Infrared data and that using FY-3B/VIRR data can produce reliable LST products for other research areas
Ping Yang - One of the best experts on this subject based on the ideXlab platform.
-
sensitivity of thermal Infrared radiation at the top of the atmosphere and the surface to ice cloud microphysics
Journal of Applied Meteorology and Climatology, 2008Co-Authors: Philippe Dubuisson, Jacques Pelon, Vincent Giraud, Bertrand Cadet, Ping YangAbstract:Abstract This paper reports on the sensitivity of the brightness temperatures associated with radiances at the surface and the top of the atmosphere, simulated for the Imaging Infrared Radiometer (IIR) 8.7-, 10.6-, and 12-μm channels under ice cloudy conditions, to the optical and microphysical properties of ice clouds. The 10.6- and 12-μm channels allow simultaneous retrieval of ice cloud optical thickness and effective particle size (Deff) less than 100 μm. It is illustrated that the particle shape and size distributions of ice crystals have noticeable effects on the brightness temperatures. Using the split window technique based on the 10.6- and 12-μm channels in conjunction with cloud properties assumed a priori, the authors show that the influence of the cloud microphysical properties can lead to differences on the order of ±10% and ±25% in retrieved effective particle sizes for small (Deff 40 μm), respectively. The impact of cloud model on retrieved optical thick...