The Experts below are selected from a list of 159 Experts worldwide ranked by ideXlab platform
Ove Andersson - One of the best experts on this subject based on the ideXlab platform.
-
In situ, high-pressure differential thermal analysis and ionic conductance of PMMA-based gels with and without TiO2 nano-Particle Filler
Electrochimica Acta, 2006Co-Authors: Ove Andersson, Thomas WågbergAbstract:In situ, high pressure differential thermal analysis and ionic conductance of PMMA-based gels with and without TiO2 nano-Particle Filler
-
A high-pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: a Filler induced change in the activation volume
Electrochimica Acta, 2005Co-Authors: Ove Andersson, Denis Ostrovskii, Per JacobssonAbstract:A high pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: A Filler induced change in the activation volume
Per Jacobsson - One of the best experts on this subject based on the ideXlab platform.
-
A high-pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: a Filler induced change in the activation volume
Electrochimica Acta, 2005Co-Authors: Ove Andersson, Denis Ostrovskii, Per JacobssonAbstract:A high pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: A Filler induced change in the activation volume
Thomas Wågberg - One of the best experts on this subject based on the ideXlab platform.
-
In situ, high-pressure differential thermal analysis and ionic conductance of PMMA-based gels with and without TiO2 nano-Particle Filler
Electrochimica Acta, 2006Co-Authors: Ove Andersson, Thomas WågbergAbstract:In situ, high pressure differential thermal analysis and ionic conductance of PMMA-based gels with and without TiO2 nano-Particle Filler
Denis Ostrovskii - One of the best experts on this subject based on the ideXlab platform.
-
A high-pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: a Filler induced change in the activation volume
Electrochimica Acta, 2005Co-Authors: Ove Andersson, Denis Ostrovskii, Per JacobssonAbstract:A high pressure study of PMMA-based gels with and without TiO2 nano-Particle Filler: A Filler induced change in the activation volume
Constantine M. Megaridis - One of the best experts on this subject based on the ideXlab platform.
-
Highly liquid-repellent, large-area, nanostructured poly(vinylidene fluoride)/poly(ethyl 2-cyanoacrylate) composite coatings: Particle Filler effects.
ACS applied materials & interfaces, 2010Co-Authors: Manish K. Tiwari, Ilker S. Bayer, Gregory Jursich, Thomas M. Schutzius, Constantine M. MegaridisAbstract:Super-repellent nanostructured composite coatings applied over large areas by spray and subsequent thermal treatment are reported. Solution blending of poly(vinylidene fluoride) and poly(ethyl 2-cyanoacrylate) is implemented to formulate Filler Particle dispersions used to apply these coatings. The wettability of these coatings is manipulated using hydrophobic poly(tetrafluoroethylene) and hydrophilic zinc oxide Particle Fillers or their combination. The resulting coatings feature contact angles up to 164 degrees for water and 154 degrees for a water and isopropyl alcohol mixture (9:1 weight ratio; surface tension approximately 40 mN/m). A self-cleaning ability is revealed by droplet roll-off angles below 10 degrees . The results show that the Fillers affect the coating surface energy and surface roughness, in turn influencing the wettability of the coatings.