The Experts below are selected from a list of 315 Experts worldwide ranked by ideXlab platform
Matthew Naylor - One of the best experts on this subject based on the ideXlab platform.
-
Research data supporting "Termination detection for fine-grained message-passing architectures"
2020Co-Authors: Matthew NaylorAbstract:This is the data package accompanying the paper "Termination detection for fine-grained message-passing architectures", to appear at ASAP 2020. It contains version 0.6.3 of Tinsel/POLite, described in the paper, along with the benchmark applications and graphs used to obtain the results. Please note that the latest versions are available at https://github.com/POETSII/tinsel.
-
Research data supporting "Tinsel: a manythread overlay for FPGA clusters"
2019Co-Authors: Matthew NaylorAbstract:This package accompanies the paper "Tinsel: a manythread overlay for FPGA clusters" to appear at FPL 2019. It includes a snapshot of the Tinsel and POLite implementations, along with the benchmarks used in the paper. Please note that the latest version of Tinsel is available at https://github.com/POETSII/tinsel.
Naylor Matthew - One of the best experts on this subject based on the ideXlab platform.
-
Research data supporting "Termination detection for fine-grained message-passing architectures"
'Organisation for Economic Co-Operation and Development (OECD)', 2020Co-Authors: Naylor MatthewAbstract:This is the data package accompanying the paper "Termination detection for fine-grained message-passing architectures", to appear at ASAP 2020. It contains version 0.6.3 of Tinsel/POLite, described in the paper, along with the benchmark applications and graphs used to obtain the results. Please note that the latest versions are available at https://github.com/POETSII/tinsel.EPSRC grant EP/N031768/1 (POETS project
-
Research data supporting "Tinsel: a manythread overlay for FPGA clusters"
'Organisation for Economic Co-Operation and Development (OECD)', 2019Co-Authors: Naylor MatthewAbstract:This package accompanies the paper "Tinsel: a manythread overlay for FPGA clusters" to appear at FPL 2019. It includes a snapshot of the Tinsel and POLite implementations, along with the benchmarks used in the paper. Please note that the latest version of Tinsel is available at https://github.com/POETSII/tinsel.EPSRC grant EP/N031768/1 (POETS project
Li Qinchuan - One of the best experts on this subject based on the ideXlab platform.
-
Comparison of various configurations of dacron and Politef-covered stents:application to modular endovascular systems
Chinese journal of experimental surgery, 2002Co-Authors: Li QinchuanAbstract:Objective To determine which graft material is the better choice for endovascular stent graft by comparing the leakage and resistance to traction of stents covered internally and externally with either Dacron (D),polytetrafluoroethylene (PTFE),or expanded PTFE (ePTFE).Methods Individual Palmaz P294 stents were assembled with collagen impregnated Dacron,PTFE or ePTFE covering the stent in one of 5 configurations (D1,D2,PTFE1,PTFE2,ePTFE).D1 and PTFE1 had a 7 mm diameter graft covering two thirds of the stent internally and another cover externally along the entire length of the stent.The same diameter grafts were used in D2 and PTFE2,in which the grafts covered the entire stent internally and externally;The ePTFE grafts were also totally covered the stent,but with 4 mm diameter graft that had been dilated to 8?mm.Resistance to leakage was tested by increasing the internal pressure (100,200 and 300?mm?Hg) with water injections;Traction was placed at both ends of the assembly to test resistance of the junction.Group comparisons were performed using ANOVA.Results Five samples of each configuration were tested.During the pressure test,4 samples collapsed (3 in D1 and 1 in D2).The amount of leakage per 15 s was (38.4±22.3)?ml for D1 and (40.4±10.3)?ml for D2 respectively;There was no leakage measured for PTFE1,PTFE2 and ePTFE.In the traction test,the samples collapsed under a force of (4.86±2.66) Newtons (N) in D1,(4.76±2.36)?N in D2,(20.49± 2.80)?N in PTFE1,(22.03±1.88)?N in PTFE2,(18.85±2.62)?N in ePTFE respectively.There was significant difference between Dacron and the PTFE groups in leakage and resistance.Conclusion PTFE stent PTFE configurations had no leakage under pressure and high resistance to traction as compared with stents covered with Dacron,suggesting that PTFE is a better material for an endovascular stent graft.ePTFE had the same characteristics as normal PTFE,but is easier to assemble in vivo.
Sarangapani Jagannathan - One of the best experts on this subject based on the ideXlab platform.
-
greener copper with dynamic spectrum management
Global Communications Conference, 2008Co-Authors: John M. Cioffi, Aakanksha Chowdhery, Hao Zou, Wooyul Lee, Sarangapani JagannathanAbstract:Power-saving benefits of Dynamic Spectrum Management (DSM) result from its increased robustness to channel and noise changes, as in this paper. A proposed intermittent noise model enables evaluation of the performance of DSM algorithms. Polite Level-1 DSM algorithm consumes much less power than non-polite DSL management algorithms in the presence of intermittent noise. Secondly, a proposed robust level- 2 DSM algorithm compares favorably with methods that change the PSDMASK only upon modem initialization or retraining. The proposed robust level-2 DSM algorithm significantly reduces power consumption. This DSM reduction of DSL transmit power can be even more significant when considering the additional loss of robustness and stability of non-DSM methods.
-
GLOBECOM - Greener Copper with Dynamic Spectrum Management
IEEE GLOBECOM 2008 - 2008 IEEE Global Telecommunications Conference, 2008Co-Authors: John M. Cioffi, Aakanksha Chowdhery, Hao Zou, Wooyul Lee, Sarangapani JagannathanAbstract:Power-saving benefits of Dynamic Spectrum Management (DSM) result from its increased robustness to channel and noise changes, as in this paper. A proposed intermittent noise model enables evaluation of the performance of DSM algorithms. Polite Level-1 DSM algorithm consumes much less power than non-polite DSL management algorithms in the presence of intermittent noise. Secondly, a proposed robust level- 2 DSM algorithm compares favorably with methods that change the PSDMASK only upon modem initialization or retraining. The proposed robust level-2 DSM algorithm significantly reduces power consumption. This DSM reduction of DSL transmit power can be even more significant when considering the additional loss of robustness and stability of non-DSM methods.
Patrice Bergeron Piret Vincent - One of the best experts on this subject based on the ideXlab platform.
-
Comparison of various configurations of dacron and Politef-covered stents:application to modular endovascular systems
2002Co-Authors: Patrice Bergeron Piret VincentAbstract:目的通过比较涤纶(D)、聚四氟乙烯(PTFE)及可膨胀性聚四氟乙烯(ePTFE)覆盖内支架不同组配的漏出量及结合点的阻力,确定带膜血管内支架的最佳材料.方法研究分5组,分别为涤纶组1(D1)、PTFE组1(PTFE1)、涤纶组2(D2)、PTFE组2(PTFE2)及可扩张PTFE组(ePTFE),每组含有5个样本.每一样本由1个Palmaz P294内支架和内置、覆盖两段D、PTFE及ePTFE组成.各组以不同的方式进行组配.增加装配内压力[100、200及300mmHg(1mmHg=0.133kPa)]来验证其外漏,在装配两端安置拉力验证其结合点的阻力.方差分析(ANOVA)用于组间比较.结果在增加装配内压力时有4个组配崩溃(D1 3个,D2 1个).每15s的漏出量在D1为(38.4±22.3)ml,D2为(40.4±10.3)ml;PTFE1、PTFE2及ePTFE无漏出.在牵拉实验中各组在如下拉力下崩溃,D1 (4.86±2.66)N,D2 (4.76±2.36)N,PTFE1 (20.49±2.80)N,PTFE2 (22.03±1.88)N,ePTFE (18.85±2.62)N.结论 PTFE是带膜血管内支架的较理想材料,ePTFE与PTFE有同样的特性但其易于体内组配.