The Experts below are selected from a list of 285 Experts worldwide ranked by ideXlab platform
Haruki Kawamura - One of the best experts on this subject based on the ideXlab platform.
-
X-Ray Powder Diffraction study of CS2 at high pressures
Journal of Physics: Condensed Matter, 2002Co-Authors: Yuichi Akahama, Y Minamoto, Haruki KawamuraAbstract:X-Ray Powder Diffraction experiments were performed at pressures up to 14 GPa and at room temperature. The orthorhombic lattice was retained at pressures up to 10 GPa. Above 10 GPa, however, a broad glassy background developed. The lattice constants, a, b, c, and the orientation angle at 2.72 GPa are 5.845, 5.220, 8.296 A and 41.3°, respectively. The orientation angle at high pressure is smaller than that of the low-temperature phase.
-
X-Ray Powder Diffraction from solid deuterium
Journal of Physics: Condensed Matter, 2002Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was first observed under high pressure at SPring-8. At pressures up to 62 GPa and room temperature, three Diffraction lines (100, 002, 101) of the hcp lattice were observed. The derived cell volume and the c/a ratio were consistent with single-crystal data. At 83 K and 94 GPa, three Diffraction lines were also obtained and assigned to the hcp lattice.
-
X-Ray Powder Diffraction from solid deuterium
Solid State Communications, 2001Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was observed under high pressure and low temperature at SPring-8. Three Diffraction lines were obtained, and they are assigned to the 100, 002 and 101 lines of the hcp lattice. The center of each deuterium molecule is still on the hcp lattice in phase II.
Elżbieta Tadeusiak - One of the best experts on this subject based on the ideXlab platform.
-
Determination of Enantiomeric Excess of Cyclophosphamide by X-Ray Powder Diffraction (XRPD)
Polish Journal of Chemistry, 2020Co-Authors: Elżbieta Tadeusiak, Rafal Kruszynski, K. MisiuraAbstract:The anticancer agent: cyclophosphamide 1 was studied by X-Ray Powder Diffraction. The linear correlations between intensity/spectra from X-Ray Powder Diffraction/and enantiomeric excess was observed.
-
Determination of enantiomeric excess of leucine and valine by X-Ray Powder Diffraction
European Journal of Chemistry, 2010Co-Authors: Elżbieta Tadeusiak, Rafal Kruszynski, Agata Trzesowska-kruszynska, Tomasz Sieranski, Bartlomiej LewinskiAbstract:Two amino acids, leucine and valine, were studied by X-Ray Powder Diffraction (XRPD). The linear correlations between intensity of racemate (decrease) or enantiomer (increase) and enantiomeric excesses were observed in each case.
Yuichi Akahama - One of the best experts on this subject based on the ideXlab platform.
-
X-Ray Powder Diffraction study of CS2 at high pressures
Journal of Physics: Condensed Matter, 2002Co-Authors: Yuichi Akahama, Y Minamoto, Haruki KawamuraAbstract:X-Ray Powder Diffraction experiments were performed at pressures up to 14 GPa and at room temperature. The orthorhombic lattice was retained at pressures up to 10 GPa. Above 10 GPa, however, a broad glassy background developed. The lattice constants, a, b, c, and the orientation angle at 2.72 GPa are 5.845, 5.220, 8.296 A and 41.3°, respectively. The orientation angle at high pressure is smaller than that of the low-temperature phase.
-
X-Ray Powder Diffraction from solid deuterium
Journal of Physics: Condensed Matter, 2002Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was first observed under high pressure at SPring-8. At pressures up to 62 GPa and room temperature, three Diffraction lines (100, 002, 101) of the hcp lattice were observed. The derived cell volume and the c/a ratio were consistent with single-crystal data. At 83 K and 94 GPa, three Diffraction lines were also obtained and assigned to the hcp lattice.
-
X-Ray Powder Diffraction from solid deuterium
Solid State Communications, 2001Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was observed under high pressure and low temperature at SPring-8. Three Diffraction lines were obtained, and they are assigned to the 100, 002 and 101 lines of the hcp lattice. The center of each deuterium molecule is still on the hcp lattice in phase II.
Osamu Shimomura - One of the best experts on this subject based on the ideXlab platform.
-
X-Ray Powder Diffraction from solid deuterium
Journal of Physics: Condensed Matter, 2002Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was first observed under high pressure at SPring-8. At pressures up to 62 GPa and room temperature, three Diffraction lines (100, 002, 101) of the hcp lattice were observed. The derived cell volume and the c/a ratio were consistent with single-crystal data. At 83 K and 94 GPa, three Diffraction lines were also obtained and assigned to the hcp lattice.
-
X-Ray Powder Diffraction from solid deuterium
Solid State Communications, 2001Co-Authors: Haruki Kawamura, Yuichi Akahama, S Umemoto, Kenichi Takemura, Yasuo Ohishi, Osamu ShimomuraAbstract:X-Ray Powder Diffraction from solid deuterium was observed under high pressure and low temperature at SPring-8. Three Diffraction lines were obtained, and they are assigned to the 100, 002 and 101 lines of the hcp lattice. The center of each deuterium molecule is still on the hcp lattice in phase II.
Hui Li - One of the best experts on this subject based on the ideXlab platform.
-
X-Ray Powder Diffraction data for Palbociclib, C24H29N7O2
Powder Diffraction, 2016Co-Authors: Shoujun Zheng, Kai Lin Xu, Pei Xiao Tang, Jiankun Peng, Xiaoli Ma, Yanmei Huang, Lijuan Chen, Hui LiAbstract:X-Ray Powder Diffraction (XRPD) data for Palbociclib, C 24 H 29 N 7 O 2 , are reported [ a = 18.182(2) A, b = 11.508(1) A, c = 5.041(1) A, α = 81.282(7)°, β = 97.423(7)°, γ = 102.415(2)°, unit-cell volume V = 1013.1(4) A 3 , Z = 2, and space group P -1. All XRPD measured lines were indexed and no detectable impurities were observed.
-
X-Ray Powder Diffraction data for niclosamide, C13H8N2O4Cl2
Powder Diffraction, 2015Co-Authors: Kai Lin Xu, Shan Shan Li, Xiao Li, Hui LiAbstract:Experimental X-Ray Powder Diffraction data, unit-cell parameters, and space group for niclosamide, C 13 H 8 N 2 O 4 Cl 2 , are reported [ a = 13.571(1) A, b = 7.181(8) A, c = 13.742(3) A, β = 97.984(7)°, unit-cell volume V = 1326.40 A 3 , Z = 4, and space group P 2 1 /c]. All measured lines were indexed and are consistent with the P 2 1 /c space group. No detectable impurity was observed.
-
X-Ray Powder Diffraction data for gemcitabine, C9H11F2N3O4
Powder Diffraction, 2015Co-Authors: Di Wu, Shan Shan Li, Pei Xiao Tang, Hui LiAbstract:X-Ray Powder Diffraction data, unit-cell parameters and space group for gemcitabine, C 9 H 11 F 2 N 3 O 4 , are reported [ a = 17.641(8) A, b = 6.985(1) A, c = 18.653(2) A, α = β = γ = 90°, unit-cell volume V = 2298.61 A 3 , Z = 8 and space group Pmna ]. All measured lines were indexed and are consistent with the Pmna space group. No detectable impurities were observed.
-
X-Ray Powder Diffraction data for bisacodyl, C22H19NO4
Powder Diffraction, 2014Co-Authors: Shan Shan Li, Xiao Qing Wu, Qing Wang, Pei Xiao Tang, Hui LiAbstract:In this paper, X-Ray Powder Diffraction data, unit-cell parameters, and space group for bisacodyl, C 22 H 19 NO 4 , are reported [ a = 9.081(3) A, b = 10.631(5) A, c = 11.549(6) A, α = 111.492(4)°, β = 108.082(3)°, γ = 101.501(3)°, unit-cell volume V = 922.368 A 3 , Z = 2, and space group P -1]. All measured lines were indexed, and no detectable impurity was observed.
-
X-Ray Powder Diffraction data for levetiracetam
Powder Diffraction, 2014Co-Authors: Kai Lin Xu, Li Li Zhang, Xiao Qing Wu, Bing Liang, Pei Xiao Tang, Hui LiAbstract:Experimental X-Ray Powder Diffraction data, unit-cell parameters, and space group for levetiracetam, C 8 H 14 N 2 O 2 , are reported [ a = 9.197(5) A, b = 8.006(0) A, c = 6.289(3) A, β = 108.457(3)°, unit-cell volume V = 439.261 A 3 , Z = 2, and space group P 2 1 ]. All measured lines were indexed and are consistent with the P 2 1 space group. No detectable impurity was observed.