Pascal Kintz - One of the best experts on this subject based on the ideXlab platform.

  • evaluation of the one step ELISA Kit for the detection of buprenorphine in urine blood and hair specimens
    Forensic Science International, 2004
    Co-Authors: Vincent Cirimele, Sophie Etienne, Marion Villain, Bertrand Ludes, Pascal Kintz
    Abstract:

    Abstract A solid-phase enzyme immunoassay involving microtiter plates was recently proposed by International Diagnostic Systems corporation (IDS) to screen for buprenorphine in human serum. The performance of the Kit led us to investigate its applicability in other biological matrices such as urine or blood, and also hair specimens. Low concentrations of buprenorphine were detected with the ELISA test and confirmed by HPLC/MS (buprenorphine concentrations measured by HPLC/MS: 0.3 ng/mL in urine, 0.2 ng/mL in blood, and 40 pg/mg in hair). The intra-assay precision values were 8.7% at 1 ng/mL of urine ( n =8), 11.5% at 2 ng/mL in serum ( n =8), and 11.5% at 250 pg/mg of hair ( n =8), respectively. The immunoassay had no cross-reactivity with dihydrocodeine, ethylmorphine, 6-monoacetylmorphine, pholcodine, propoxyphene, dextromoramide, dextrometorphan at 1 and 10 mg/L, or codeine, morphine, methadone, and its metabolite EDDP. A 1% cross-reactivity was measured for a norbuprenorphine concentration of 50 ng/mL. Finally, the immunoassay was validated by comparing authentic specimens results with those of a validated HPLC/MS method. From the 136 urine samples tested, 93 were positive (68.4%) after the ELISA screening test (cutoff: 0.5 ng/mL) and confirmed by HPLC/MS (buprenorphine concentrations: 0.3–2036 ng/mL). From the 108 blood or serum samples screened, 27 were positive (25%) after the ELISA test with a cutoff value of 0.5 ng/mL (buprenorphine concentrations: 0.2–13.3 ng/mL). Eighteen hair specimens were positive (72%) after the screening (cutoff: 10 pg/mg) and confirmed by LC/MS (buprenorphine concentrations: 40–360 pg/mg). The ELISA method produced false positive results in less than 21% of the cases, but no false negative results were observed with the immunological test. Four potential adulterants (hypochloride 50 mL/L, sodium nitrite 50 g/L, liquid soap 50 mL/L, and sodium chloride 50 g/L) that were added to 10 positive urine specimens (buprenorphine concentrations in the range 5.3–15.6 ng/mL), did not cause a false negative response by the immunoassay.

D. Michael Olive - One of the best experts on this subject based on the ideXlab platform.

RASA SANTOCKYTE - One of the best experts on this subject based on the ideXlab platform.

  • Increased sensitivity of HIV-1 p24 ELISA using a photochemical signal amplification system
    Journal of Acquired Immune Deficiency Syndromes, 2015
    Co-Authors: SIMON BYSTRYAK, RASA SANTOCKYTE
    Abstract:

    BACKGROUND: In this study we describe a photochemical signal amplification method (PSAM) for increasing of the sensitivity of enzyme-linked immunosorbent assay (ELISA) for determination of HIV-1 p24 antigen. The photochemical signal amplification method is based on an autocatalytic photochemical reaction of a horseradish peroxidase (HRP) substrate, orthophenylenediamine (OPD). METHODS: To compare the performance of PSAM-boosted ELISA with a conventional colorimetric ELISA for determination of HIV-1 p24 antigen we employed a PerkinElmer HIV-1 p24 ELISA Kit, using conventional ELISA alongside ELISA + PSAM. RESULTS: In the present study, we show that PSAM technology allows one to increase the analytical sensitivity and dynamic range of a commercial HIV-1 p24 ELISA Kit, with and without immune-complex disruption, by a factor of approximately 40-fold. CONCLUSIONS: ELISA + PSAM is compatible with commercially available microtiter plate readers, requires only an inexpensive illumination device, and the PSAM amplification step takes no longer than 15 min. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods.

Vincent Cirimele - One of the best experts on this subject based on the ideXlab platform.

  • evaluation of the one step ELISA Kit for the detection of buprenorphine in urine blood and hair specimens
    Forensic Science International, 2004
    Co-Authors: Vincent Cirimele, Sophie Etienne, Marion Villain, Bertrand Ludes, Pascal Kintz
    Abstract:

    Abstract A solid-phase enzyme immunoassay involving microtiter plates was recently proposed by International Diagnostic Systems corporation (IDS) to screen for buprenorphine in human serum. The performance of the Kit led us to investigate its applicability in other biological matrices such as urine or blood, and also hair specimens. Low concentrations of buprenorphine were detected with the ELISA test and confirmed by HPLC/MS (buprenorphine concentrations measured by HPLC/MS: 0.3 ng/mL in urine, 0.2 ng/mL in blood, and 40 pg/mg in hair). The intra-assay precision values were 8.7% at 1 ng/mL of urine ( n =8), 11.5% at 2 ng/mL in serum ( n =8), and 11.5% at 250 pg/mg of hair ( n =8), respectively. The immunoassay had no cross-reactivity with dihydrocodeine, ethylmorphine, 6-monoacetylmorphine, pholcodine, propoxyphene, dextromoramide, dextrometorphan at 1 and 10 mg/L, or codeine, morphine, methadone, and its metabolite EDDP. A 1% cross-reactivity was measured for a norbuprenorphine concentration of 50 ng/mL. Finally, the immunoassay was validated by comparing authentic specimens results with those of a validated HPLC/MS method. From the 136 urine samples tested, 93 were positive (68.4%) after the ELISA screening test (cutoff: 0.5 ng/mL) and confirmed by HPLC/MS (buprenorphine concentrations: 0.3–2036 ng/mL). From the 108 blood or serum samples screened, 27 were positive (25%) after the ELISA test with a cutoff value of 0.5 ng/mL (buprenorphine concentrations: 0.2–13.3 ng/mL). Eighteen hair specimens were positive (72%) after the screening (cutoff: 10 pg/mg) and confirmed by LC/MS (buprenorphine concentrations: 40–360 pg/mg). The ELISA method produced false positive results in less than 21% of the cases, but no false negative results were observed with the immunological test. Four potential adulterants (hypochloride 50 mL/L, sodium nitrite 50 g/L, liquid soap 50 mL/L, and sodium chloride 50 g/L) that were added to 10 positive urine specimens (buprenorphine concentrations in the range 5.3–15.6 ng/mL), did not cause a false negative response by the immunoassay.

Stephen J Dumler - One of the best experts on this subject based on the ideXlab platform.

  • single tier testing with the c6 peptide ELISA Kit compared with two tier testing for lyme disease
    Diagnostic Microbiology and Infectious Disease, 2013
    Co-Authors: Gary P Wormser, Martin E Schriefer, Maria E Aguerorosenfeld, Andrew E Levin, Allen C Steere, Robert B Nadelman, John Nowakowski, Adriana Marques, Barbara J B Johnson, Stephen J Dumler
    Abstract:

    Abstract For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA Kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7–71.1) and 35.2% (95% CI 30.6–40.1), respectively ( P P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively ( P