Oxygen Supply Equipment

14,000,000 Leading Edge Experts on the ideXlab platform

Scan Science and Technology

Contact Leading Edge Experts & Companies

Scan Science and Technology

Contact Leading Edge Experts & Companies

The Experts below are selected from a list of 1224 Experts worldwide ranked by ideXlab platform

Yu Zeng - One of the best experts on this subject based on the ideXlab platform.

  • A Test Method for Testing the Flow of Air Oxygen Supply Equipment
    2018 9th International Conference on Mechanical and Aerospace Engineering (ICMAE), 2018
    Co-Authors: Dongsheng Jiang, Xueqin Bu, Jun Huang, Yu Zeng
    Abstract:

    With the development of aviation military and civilian aircraft, the aviation Oxygen Supply Equipment also has higher technical improvements and system innovations. In order to simulate the work of aviation Oxygen Supply Equipment and accurately test the volume flow under high altitude condition, the flow detection method of damping Equipment is adopted to detect the flow of Oxygen Equipment. The gas density correction is not needed during the testing process. The range setting, damper tube structure and other aspects are described, the test principle, identification/calibration methods were studied and verified and the flow test method has been applied for the new test Equipment.

Dongsheng Jiang - One of the best experts on this subject based on the ideXlab platform.

  • A Test Method for Testing the Flow of Air Oxygen Supply Equipment
    2018 9th International Conference on Mechanical and Aerospace Engineering (ICMAE), 2018
    Co-Authors: Dongsheng Jiang, Xueqin Bu, Jun Huang, Yu Zeng
    Abstract:

    With the development of aviation military and civilian aircraft, the aviation Oxygen Supply Equipment also has higher technical improvements and system innovations. In order to simulate the work of aviation Oxygen Supply Equipment and accurately test the volume flow under high altitude condition, the flow detection method of damping Equipment is adopted to detect the flow of Oxygen Equipment. The gas density correction is not needed during the testing process. The range setting, damper tube structure and other aspects are described, the test principle, identification/calibration methods were studied and verified and the flow test method has been applied for the new test Equipment.

Xueqin Bu - One of the best experts on this subject based on the ideXlab platform.

  • A Test Method for Testing the Flow of Air Oxygen Supply Equipment
    2018 9th International Conference on Mechanical and Aerospace Engineering (ICMAE), 2018
    Co-Authors: Dongsheng Jiang, Xueqin Bu, Jun Huang, Yu Zeng
    Abstract:

    With the development of aviation military and civilian aircraft, the aviation Oxygen Supply Equipment also has higher technical improvements and system innovations. In order to simulate the work of aviation Oxygen Supply Equipment and accurately test the volume flow under high altitude condition, the flow detection method of damping Equipment is adopted to detect the flow of Oxygen Equipment. The gas density correction is not needed during the testing process. The range setting, damper tube structure and other aspects are described, the test principle, identification/calibration methods were studied and verified and the flow test method has been applied for the new test Equipment.

Jun Huang - One of the best experts on this subject based on the ideXlab platform.

  • A Test Method for Testing the Flow of Air Oxygen Supply Equipment
    2018 9th International Conference on Mechanical and Aerospace Engineering (ICMAE), 2018
    Co-Authors: Dongsheng Jiang, Xueqin Bu, Jun Huang, Yu Zeng
    Abstract:

    With the development of aviation military and civilian aircraft, the aviation Oxygen Supply Equipment also has higher technical improvements and system innovations. In order to simulate the work of aviation Oxygen Supply Equipment and accurately test the volume flow under high altitude condition, the flow detection method of damping Equipment is adopted to detect the flow of Oxygen Equipment. The gas density correction is not needed during the testing process. The range setting, damper tube structure and other aspects are described, the test principle, identification/calibration methods were studied and verified and the flow test method has been applied for the new test Equipment.

Hong Houyu - One of the best experts on this subject based on the ideXlab platform.

  • discussion on Oxygen Supply Equipment and containers for clinical application
    China Health Industry, 2015
    Co-Authors: Hong Houyu
    Abstract:

    Introduced has levels various hospital clinical for Oxygen Equipment and for Oxygen container application development trend, described has different for Oxygen Equipment and container of composition, analysis has big small hospital application different for Oxygen Equipment and container of advantages and disadvantages, pointed out that has hospital using for Oxygen Equipment and container should note matters, prevent security accident occurred, summary has hospital should according to scale size select different of for Oxygen Equipment and container, further improve for Oxygen Equipment and container of utilization, guarantee clinical with Oxygen security and Oxygen therapy effect.